The ADE7868AACPZ-RL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADE7868AACPZ-RL: A Three Phase Metering Front End and the 3000 to 1 It Has to Hold
What this part is
The ADE7868A is a polyphase energy measurement integrated circuit for three phase three wire or four wire services, delta or wye. It contains second order sigma delta converters, a digital integrator, reference circuitry and a fixed function digital signal processor that computes active, reactive and apparent energy together with root mean square values, and it reports through serial interfaces and three pulse outputs. Analog Devices states compliance with EN 50470-1, EN 50470-3, IEC 62053-21, IEC 62053-22 and IEC 62053-23, and supports both current transformers and di/dt sensors such as Rogowski coils. A dedicated converter channel is provided for neutral current, and the neutral current can also be estimated from the vector sum of the three phase currents where no neutral sensor is fitted.
Published figures that matter to a buyer
| Service types | Three phase, three or four wire, delta or wye |
| Energy quantities | Total active, reactive and apparent, plus fundamental active and reactive |
| Accuracy over 1000 to 1 | 0.1 percent typical at 25 degrees C |
| Accuracy over 3000 to 1 | 0.2 percent typical at 25 degrees C |
| Current sensors | Current transformer and di/dt |
| Neutral current | Dedicated converter channel, or estimated from the phase sum |
| RMS update | Every 8 kHz, with low ripple averaged values every 1.024 s |
| Pulse outputs | Three, CF1 to CF3 |
| Power quality | Short duration over and under voltage, current variation, line period |
| Standards | EN 50470-1 and -3, IEC 62053-21, -22, -23 |
Where the headline numbers stop
The accuracy statements carry two conditions that a meter qualification has to respect. They are typical figures at 25 degrees C, and the temperature behaviour is not part of the headline, so a Class 0.5S or Class 0.2S meter still has to be verified over the operating range with its own shunt and its own calibration. The dynamic range is also stated as a ratio of full scale: over 3000 to 1 a 60 A service is specified down to 20 mA, and a 100 A service down to 33 mA, which is where a small load sits and where the error budget is tightest.
The two rms paths answer different questions. The 8 kHz update gives 125 us of resolution, or 160 updates in a 50 Hz cycle, which is enough to follow a motor start; the 1.024 s low ripple registers average that stream and are what a billing register should use. Neither path follows a 200 ms voltage dip with the waveform detail that a power quality report needs, which is why the part also exposes waveform sampling registers and short duration event detection. The three pulse outputs can be assigned to different quantities, so the calibration and the billing pulse do not have to be the same signal.
Applications where it fits
- Three phase revenue meters for wye and delta services, including four wire with neutral.
- Sub metering in industrial panels where a DIN rail module has to report per feeder energy.
- Power quality recorders that need both billing registers and event detection.
- Charging and energy management equipment that bills by measured energy rather than by time.
Two questions buyers ask
Does it work with a Rogowski coil? Yes, the di/dt input with the internal digital integrator is exactly that case. A current transformer input needs the integrator bypassed and the burden resistor chosen for the secondary current, so the two sensor types use different front end components on the same part.
Can neutral current be measured without a fourth sensor? The device can estimate it as the root sum square of the three phase currents, which is enough for imbalance reporting but not for a tamper case where the neutral carries current that the phases do not. A four wire meter with tamper detection uses the dedicated converter channel.
Sourcing notes and next step
The ADE7868AACPZ-RL is the LFCSP body on tape and reel, and the family includes variants with and without fundamental only measurement and with different pulse output counts. Meter builds are certified as a whole, so a substitution has to be re-verified against the standards rather than treated as a pin swap. We source the family with date code traceability and can quote the waveform sampling variant where power quality is required. The analog and mixed signal IC family page lists the metering and converter line, the obsolete part cross reference hub covers the long life case, and the BOM shortage recovery page covers the allocation case.
Request Quote — In Stock, 100% New & Original, Full Warranty