ADA4638-1ARZ-R7
Product Specifications
ADA4638-1ARZ-R7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADA4638-1ARZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADA4638-1ARZ-R7: a 30 V zero drift amplifier with 4 microvolts of offset
The ADA4638-1ARZ-R7 is a single zero drift amplifier that runs from 4.5 V to 30 V on a single supply, or plus and minus 2.25 V to plus and minus 15 V, with 4 microvolts of maximum offset and 0.05 microvolts per degree C of maximum drift. Common mode rejection is 130 dB minimum, power supply rejection 120 dB minimum and open loop gain 130 dB minimum, on 0.95 mA of supply current. It is built for weigh scales, strain gauge and thermocouple channels, and medical instrumentation.
Published values
| Parameter | Value |
|---|---|
| Channels | 1 |
| Offset voltage | 4 microvolts maximum |
| Offset drift | 0.05 microvolts per degree C maximum, 7.25 microvolts over a 145 kelvin span |
| Low frequency noise | 1.2 microvolts peak to peak, 0.1 Hz to 10 Hz, no 1/f corner |
| Common mode rejection | 130 dB minimum |
| Power supply rejection | 120 dB minimum |
| Open loop gain | 130 dB minimum |
| Supply current | 0.95 mA maximum, 28.5 mW at 30 V |
| Supply | 4.5 V to 30 V single, plus and minus 2.25 V to plus and minus 15 V dual |
| Input common mode | includes the lower supply rail |
| Output | rail to rail |
| Packages | 8-lead SOIC, 8-lead LFCSP with exposed pad |
Zero drift changes the calibration plan
A part with 4 microvolts of offset and 0.05 microvolts per degree C of drift over a 145 kelvin span moves by 7.25 microvolts across the whole range, which is a tenth of one code of a 16-bit converter on a 5 V span at 76 microvolts per code, and less than the offset itself. An instrument built around it does not need a temperature compensation table or a two point calibration over temperature; a single point calibration at production holds to the accuracy of the reference.
The same arithmetic explains why a customer replacing a precision bipolar part with this one can remove a trim potentiometer, a calibration step and the associated test time. Those are real cost savings on a build of any volume, and they are usually larger than the price difference between the two amplifiers.
Chopping, noise and the artefacts to look for
A zero drift amplifier works by chopping, and the artefacts are input bias current spikes and intermodulation around the chopping frequency. The published 1.2 microvolts peak to peak of low frequency noise with no 1/f corner is the benefit; the bias current behaviour is the cost. On a source impedance above a few tens of kilohms the current spikes turn into voltage noise that does not appear in the noise density figure, and a lower impedance source or an input filter is needed.
The supply rejection of 120 dB minimum is what makes a 30 V part usable on a rail that also feeds relays or solenoids. On an industrial board the rail moves with load, and a 1 V movement on a 120 dB part is 1 microvolt at the input, which is inside the offset. A part with 80 dB of rejection would see 100 microvolts and the channel would drift with the machine cycle.
Reading the two offset figures on the same page
The front page of the data sheet publishes 4 microvolts of maximum offset and 0.05 microvolts per degree C of maximum drift, and the portfolio table printed on the same page lists 4.5 microvolts and 0.08. Both are Analog Devices numbers, they are not the same, and a customer building a comparison sheet will find the difference. The front page figures are the ones to quote, and the reason to know about the other pair is to answer the question before it becomes a doubt about the part.
A 30 V supply with a 0.95 mA maximum current is 28.5 mW, which is low for a high voltage part and matters on a 4 to 20 mA loop instrument where the whole circuit shares a current budget. The 4.5 V minimum supply also means the part works on a 5 V rail, so the same amplifier can be used on the analogue section of a 5 V system and on the 24 V field side without a second part number.
For a board that has to keep running while a reel runs out, medical device components is where the family alternatives sit, defense grade components is the check list before a substitute goes in, and component obsolescence management is how a gap is covered without a new line item.
Two questions buyers ask
Does the exposed pad on the LFCSP need to be soldered? Yes. The data sheet recommends connecting the exposed pad to the negative supply, and the thermal and offset behaviour at the specified numbers assume it is soldered. A floating pad is a reliability question, not only a thermal one.