ADA4522-1ARZ
Product Specifications
ADA4522-1ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADA4522-1ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADA4522-1ARZ: a single zero drift amplifier that runs to 55 volts
The ADA4522-1ARZ is the single channel zero drift amplifier of the ADA4522 family in an 8-lead SOIC. The two published numbers that decide where it can be used are 5 microvolts of maximum offset and a single supply range of 4.5 to 55 volts, with a 60 volt absolute maximum. That combination is rare: most chopper amplifiers stop at 5 or 6 volts, and most 40 volt precision amplifiers are not zero drift. What follows is the published table and the three places where the numbers change a 48 volt rail build.
Published values
| Parameter | Value |
|---|---|
| Channels | 1 |
| Package | 8-lead SOIC (R-8), also offered in 8-lead MSOP |
| Offset voltage | 5 uV maximum |
| Offset voltage drift | 22 nV/C maximum |
| Voltage noise, 0.1 Hz to 10 Hz | 117 nV peak to peak typical |
| Voltage noise density | 5.8 nV/root Hz typical at 1 kHz, gain 100 |
| Input bias current | 50 pA typical |
| Unity gain crossover | 3 MHz typical |
| Gain bandwidth product | 2.7 MHz typical |
| Single supply operation | 4.5 V to 55 V |
| Dual supply operation | plus minus 2.25 V to plus minus 27.5 V |
| Absolute maximum supply | 60 V |
| Input range | includes the negative rail, rail to rail output |
| Other | integrated EMI filters, AEC-Q100 qualified |
| Operating temperature | -40 C to +125 C |
Why 55 volts changes a 48 volt rail
A 48 volt industrial rail with a 10 percent tolerance reaches 52.8 volts, which leaves 2.2 volts of headroom against the 55 volt published maximum and 7.2 volts against the 60 volt absolute maximum. That is enough for a supply that is regulated, and it is not enough for one that is also exposed to load dump or to a hot plug event unless the front end clamps. The distinction matters: 55 volts is an operating limit, 60 volts is the point where the part is no longer guaranteed to survive.
The other half of the 55 volt story is the input range. The inputs include the negative rail and the output swings to both rails, so a high side sense resistor on a 48 volt rail can be read with the amplifier powered from the same 48 volts, without a separate low voltage rail and without a level shift stage.
Chopping: the 117 nanovolt figure is peak to peak, not a density
The 0.1 Hz to 10 Hz noise is published as 117 nanovolts peak to peak typical, and the broadband density is 5.8 nanovolts per root hertz at 1 kHz. The two are not interchangeable. Over a 1 kilohertz bandwidth the density integrates to 183.4 nanovolts rms, which is a larger number than the peak to peak figure, and a customer comparing the two without units will conclude the part got worse at higher frequency.
What the peak to peak figure actually buys is drift free behaviour near DC, which is the band where a thermocouple or a strain gauge lives. A 5 microvolt offset with 22 nanovolts per degree C of drift is 3.63 microvolts across the full 165 kelvin span, so the drift term is smaller than the offset term for the first time in this comparison. That is the whole point of the chopper.
Bandwidth is what zero drift costs
The unity gain crossover is 3 MHz typical and the gain bandwidth product is 2.7 MHz, which gives about 27 kilohertz of closed loop bandwidth at a gain of 100. A 10 MHz precision amplifier of the same generation gives 100 kilohertz at the same gain. If the signal of interest sits below a few kilohertz, the chopper is the better part; if the loop has to cross over at tens of kilohertz, the chopper's phase shift will erode the margin the compensation was built for.
The 3 MHz crossover and the internal chopping also mean the output impedance rises above a few hundred kilohertz. A successive approximation converter driven directly from this amplifier needs either a longer acquisition window or a buffer, and that is a board level consequence of a datasheet number rather than a fault in the part.
Two pages worth reading before a purchase order goes out are the ADI second source page and how to verify a drop in replacement; the first lists what else fits the socket, the second is the test sequence for a drop in, and component lead time solutions covers the case where the shortage is already on the line.
Two questions buyers ask
Is the 55 volt rating an operating limit or a survival limit? Operating. The part is specified to 55 volts, and the absolute maximum is 60 volts. A 48 volt rail with a 10 percent tolerance reaches 52.8 volts, which is inside the operating range but close enough that a transient clamp is still the right choice.
Can this part replace a 5 volt chopper in an existing socket? Electrically the 4.5 volt minimum supply and the rail to rail output allow it, but the pinout and the package have to be checked against the part being replaced, and the 3 MHz crossover is lower than most 5 volt choppers, so the loop compensation has to be rechecked.