AD8609ARZ
Product Specifications
AD8609ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD8609ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD8609ARZ: four 40 microamp precision amplifiers in a 14-lead SOIC
The AD8609ARZ is the four channel member of the AD8603/AD8607/AD8609 family in a 14-lead SOIC, with a 50 uV maximum offset, a 1 pA maximum bias current and 400 kHz of bandwidth for 40 uA per amplifier from 1.8 V. Four accurate DC channels for 160 uA is a combination that no general purpose quad comes close to.
Published values
| Parameter | Value |
|---|---|
| Offset voltage | 12 uV typical, 50 uV maximum per amplifier |
| Offset voltage drift | 1 uV/C typical, 4.5 uV/C maximum |
| Input bias current | 0.2 pA typical, 1 pA maximum |
| Supply current, four channels | 160 uA typical, 200 uA maximum |
| Gain bandwidth | 400 kHz at 5 V, 385 kHz at 1.8 V |
| Slew rate | 0.1 V/us |
| Voltage noise density | 25 nV/root Hz at 1 kHz |
| Settling to 0.1% | 23 us on a 2 V step at unity gain |
| CMRR and PSRR | 80 dB minimum |
| Input range | 0.3 V beyond both rails |
| Package | 14-lead narrow SOIC and 14-lead TSSOP |
| Supply range | 1.8 V to 5 V single supply |
Four precision channels inside a two hundred microamp budget
A general purpose quad at 45 uA per amplifier and a 6 mV offset costs 180 uA; this part costs 160 uA and gives a 50 uV offset with a guaranteed 4.5 uV/C drift. On a 3.3 V rail the whole bank is 0.53 mW, which is the sort of number that lets a four channel instrument run for a year on a lithium cell.
Throughput follows the slew rate, not the bandwidth
Four channels at 23 us of settling each give a 10 kSPS aggregate scan, and that is with no allowance for the multiplexer or the converter. A four channel 100 kSPS instrument cannot be built on this part, whatever the 400 kHz bandwidth suggests. Estimating the scan rate from the bandwidth instead of the settling time is the most common mistake made with micropower amplifiers.
Bias current and board leakage
One picoamp of maximum bias current is only an advantage if the board is cleaner than that. A fingerprint or a patch of no-clean flux on a humid day is nanoamps, and a 10 GOhm leakage path at 3 V is 300 pA. For a pH or photodiode input, guard the input trace, keep the package dry and treat the 1 pA figure as a ceiling on the amplifier rather than a promise about the assembly.
Where four accurate channels pay
Multi-point temperature monitoring with thermocouples or thermistors, four electrode electrochemical sensors, strain gauge arrays, and portable medical monitors with four simultaneous DC channels. In each case the accuracy is needed and the speed is not, which is exactly the trade this family makes.
Buyers usually arrive at medical device components to find the family alternatives, then use the amplifier cross reference to confirm a substitute before it is fitted; vendor consolidation is the routine for a part that has already stopped shipping.
Two questions buyers ask
Does the quad version draw four times the current of the single? Yes, 160 uA typical against 40 uA, since the figure is per amplifier and the four channels are independent.
What is the temperature behaviour of the offset? Fifty microvolts at 25 C plus up to 4.5 uV/C, which is 450 uV over a 100 C excursion. The room temperature figure should not be used for a channel that runs hot.