AD8420ARMZ-R7
Product Specifications
AD8420ARMZ-R7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD8420ARMZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD8420ARMZ-R7: 90 uA of Supply Current Against 55 nV of Input Noise
The AD8420 is a wide supply range, micropower instrumentation amplifier with rail to rail output, a maximum supply current of 90 uA, a minimum common mode rejection of 100 dB, and 55 nV per root hertz of input voltage noise. Gain is set with two external resistors as one plus the ratio of R2 to R1, the maximum differential input is 1 V, and the input voltage range extends below ground. It runs from a single supply of 2.7 V to 36 V or a dual supply of plus and minus 2.7 V to 18 V, which covers a 4 mA to 20 mA loop, a 24 V industrial rail and a single coin cell with the same part number.
The noise and the bandwidth have to be read together
At a gain of 100 the bandwidth is 2.5 kHz, so the input referred noise over that band is 55 nV per root hertz times the square root of 2500, which is 2.75 uV rms. The maximum offset is 125 uV, which is forty five times that noise. In other words, at the gain where the part is quietest in relative terms its own offset still dominates the error budget, and the drift of 1 uV per degree Celsius over 100 degrees is 100 uV, comparable to the offset itself. Trimming the offset at one temperature therefore does not deliver the part's best accuracy over a range, which is the same conclusion the drift figure states.
Why the current is 90 uA and not 900
The amplifier uses an indirect current feedback topology, which senses the differential input with one transconductance stage and forces the feedback through a second one. Because the two stages are matched by the same bias current, the input common mode range is nearly independent of the output swing, so signals at or slightly below ground can be amplified from a single supply. The same architecture is what keeps the supply current at 90 uA: there is no second gain stage and no output buffer chain drawing extra current. A 90 uA budget over a year is 788 mAh, which is a coin cell's worth of charge for one amplifier, so this class of part is bought for battery instruments first.
| Parameter | Value | What it decides |
|---|---|---|
| Supply current | 90 uA maximum | 788 mAh over a year of continuous operation |
| Supply range | 2.7 V to 36 V single | One part for a coin cell and a 24 V loop |
| Common mode rejection | 100 dB minimum | Ten parts per million of the common mode |
| Input noise | 55 nV per root hertz | 2.75 uV rms over the 2.5 kHz band |
| Offset, maximum | 125 uV | Forty five times the in band noise |
| Offset drift, maximum | 1 uV per degree C | 100 uV over 100 degrees, equal to the offset |
| Bandwidth at gain 100 | 2.5 kHz | Sets the noise band and the loop speed |
| Gain equation | 1 plus R2 over R1 | Two resistors, no matched pair |
| Maximum differential input | 1 V | Limits the bridge excitation offset |
| Output | Rail to rail | Swing independent of the common mode |
| Capacitive load | About 700 pF | Drives a filter without a series resistor |
| Temperature range | -40 C to +125 C | Specified to +85 C, operational to +125 C |
| Package | 8-lead MSOP | Small board area for an instrumentation stage |
The gain resistor tolerance is the gain error
With gain set as one plus R2 over R1, the error in the gain is the error in the ratio of the two resistors and not their absolute tolerance. Two 1 percent resistors with an uncorrelated error give a ratio error of about 1.4 percent; a matched pair gives a ratio error a factor of ten better. At a gain of 100, the ratio is 99 to 1, so a 1 kohm and a 99 kohm resistor in 0.1 percent parts set the gain to within 0.14 percent. That is why the data sheet's low gain drift claim depends on the resistor pair rather than on the amplifier alone.
Where the input range below ground comes from
The input voltage range extends below the negative rail, which allows a thermocouple or a bridge with a slight offset to be connected directly without a negative supply. The limit is the 1 V maximum differential input, which protects the input stage against an open bridge and against a reverse connected source. A 4 mA to 20 mA receiver built on this part puts the sense resistor in the return leg and takes the loop current down to a few tens of millivolts, well inside the differential limit, while the common mode sits at the loop supply and is rejected by the 100 dB minimum figure.
Procurement and the resistor pair
The amplifier and its two gain resistors are usually bought and specified together, and the resistor pair is the item that decides the gain error over temperature. Where this part is being second sourced, the numbers to compare are supply current, common mode rejection and the input range below ground, because a part that only reaches the negative rail cannot replace this one in a single supply bridge circuit. Availability is tracked through amplifier cross reference, and the wider supply question for battery instruments is covered in ADI part second source. Where the board is being changed to a different gain, the checks are listed in one stop BOM sourcing.