AD7865BSZ-1REEL
Product Specifications
AD7865BSZ-1REEL
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD7865BSZ-1REEL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD7865BSZ-1REEL: Four Channels Sampled at the Same Instant, 350 kSPS on One
The AD7865BSZ-1REEL is a four channel, 14-bit, simultaneous sampling converter that runs from a single 5 V supply. Analog Devices builds in four track and hold amplifiers, a 2.4 us successive approximation converter, a 2.5 V reference, the clock oscillator and a high speed parallel interface that also talks to 3 V processors. Input ranges are plus or minus 10 V, plus or minus 5 V, plus or minus 2.5 V, 0 V to 5 V and 0 V to 2.5 V. Maximum throughput is 350 kSPS on a single channel and 100 kSPS with all four in the sequence. Power is 115 mW typical, 15 uW in the power saving mode, the body is a 44-lead PQFP, and the vendor lists 14 part models from $28.89 at 1ku.
Simultaneous sampling is about phase, not about speed
A multiplexed converter measures channel one, then channel two, and the time between them is a phase error in the sampled data. At 50 Hz, a 9.6 us gap between the first and last conversion is 0.17 degrees of phase. At 400 Hz it is 1.38 degrees, and at 1 kHz it is 3.46 degrees. In a three phase power measurement or a quadrature demodulator those numbers are the difference between a correct power factor and a wrong one. The AD7865 closes all four track and holds on one CONVST edge, so the samples represent one instant and the subsequent conversions only digitise what was captured.
350 kSPS and 100 kSPS are the same part
One channel converts in 2.4 us and acquires in 0.35 us, which supports 350 thousand conversions per second. Four channels take four times 2.4 us plus 0.35 us, or 9.95 us, which is 100 thousand complete four channel scans per second. The two figures differ by the channel count, not by a speed grade. A buyer who needs 350 kSPS per channel across four channels is asking for 1.4 million conversions per second and needs four parts, not one.
Resolution against the range you choose
Fourteen bits over a 20 V span is 1.22 mV per step. Over 10 V it is 610 uV, and over 5 V it is 305 uV. The converter is the same in all three cases, so the range setting is really a decision about resolution: a plus or minus 2.5 V transducer uses the smallest step, and a plus or minus 10 V industrial signal gives up a factor of four in resolution for the headroom.
The published table, as the vendor states it
| Parameter | Value |
|---|---|
| Resolution | 14 bit |
| Channels | 4, simultaneously sampled |
| Conversion time | 2.4 us per channel, 0.35 us acquisition |
| Throughput | 350 kSPS single channel, 100 kSPS all four |
| Input ranges | plus or minus 10, 5, 2.5 V, 0 to 5 V, 0 to 2.5 V |
| Reference | 2.5 V on chip |
| Overvoltage protection | plus or minus 20 V on the analog inputs |
| Supply and power | 5 V single, 115 mW typical, 15 uW standby |
| Interface | 14-bit parallel, 3 V compatible |
| Package and price | 44-lead PQFP, from $28.89 at 1ku |
A 20 V overvoltage on a 10 V input
The analog inputs tolerate plus or minus 20 V without damage and without disturbing a conversion in progress. On the plus or minus 10 V range that is twice full scale, which covers the usual industrial fault case of a 24 V loop being wired to a signal input. The protection is on the die, so no external clamp is needed for that level, although a series resistor and a transient suppressor are still normal practice at a field connector.
Buyer questions
Do I lose throughput if I convert fewer channels? No, you gain it. The channel sequence is selectable in hardware or through a register, and the vendor states 350 kSPS for a single channel. Reading two channels gives roughly 175 kSPS and three gives about 116 kSPS, all derived from the same 2.4 us conversion plus 0.35 us acquisition.
Does it need an external reference or driver? The reference and the signal conditioning are on the die, and the input ranges include plus or minus 10 V, so a bipolar industrial signal can connect through a resistor and a clamp rather than through a custom amplifier stage. That is the main reason this part stays in builds that would otherwise need three separate components per channel.
Family page for the category: Analog and mixed-signal ICs. For converter cross references see ADC and DAC cross reference, and for long lead time planning on legacy converters see component lead time solutions.
Request Quote — In Stock, 100% New & Original, Full Warranty