Contact Us

AD7799BRUZ-REEL

Brand: Analog Devices
Analog Devices AD7799BRUZ-REEL is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7799BRUZ-REEL — Analog & Mixed-Signal ICs | Superb Automation

AD7799BRUZ-REEL

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7799BRUZ-REEL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

AD7799BRUZ-REEL: three differential channels, 27 nV of noise at 4.17 Hz, and 380 uA for the whole front end

The AD7799BRUZ-REEL is an Analog Devices 24-bit sigma-delta converter with three differential inputs and an on chip low noise instrumentation amplifier, in a 16-lead TSSOP. At a gain of 64 and an output rate of 4.17 Hz the rms noise is 27 nV, and at 16.7 Hz it is 65 nV; the output rate itself is programmable from 4.17 Hz to 470 Hz. The part draws 380 uA typical and 1 uA maximum in power-down, works from 2.7 V to 5.25 V, and includes an internal clock oscillator, simultaneous 50 Hz and 60 Hz rejection, a reference detect function, a low side power switch, programmable digital outputs and burnout currents for sensor fault detection. It is specified for weighing, pressure, strain gauge and gas analysis work rather than for high speed capture. It is listed on the analog and mixed-signal IC line card.

27 nV at a gain of 64 is a 120 dB front end, which is 17.7 noise free bits

With a 2.5 V reference and a gain of 64 the full scale input is 39.06 mV, whose rms value for a sine is 27.62 mV. Against 27 nV of noise that is 120.2 dB of dynamic range. The number that matters for a weighing scale is noise free resolution, which uses peak to peak noise, about 6.6 times the rms value, so 178 nV against 39.06 mV is 17.7 bits. Read the two together and the part is a 17 to 18 bit front end for a millivolt level sensor, with the remaining codes available for averaging. The gain stage moves the full scale, not the noise floor in input referred terms, so the ratio stays near 120 dB across the gain settings and the noise free figure does not improve by switching gain.

ParameterVendor figureDerived figure
Channels3 differential, with in ampa bridge, its temperature sensor and a battery check on one part
Noise at 4.17 Hz27 nV rms at gain 64120.2 dB dynamic range, 17.7 noise free bits
Noise at 16.7 Hz65 nV rms at gain 642.4 times the noise for four times the rate
Full scale at gain 6439.06 mV with a 2.5 V reference2.33 nV per code, far below the noise, so the amplifier sets the range
Conversion time at 4.17 Hz240 ms per conversiona settled reading four times a second
Conversion time at 470 Hz2.13 ms per conversiona full three channel scan in 6.38 ms
Supply current380 uA typical1.9 mW at 5 V, 1.03 mW at 2.7 V
Power-down1 uA maximuma battery instrument can sleep between readings
Rejectionsimultaneous 50 Hz and 60 Hzboth line frequencies rejected at once, no variant to order
Supply range2.7 V to 5.25 Va 3.6 V lithium cell or a 5 V loop rail

The burnout current and the low side switch are diagnostics, not features

A strain gauge bridge that has lost a connection reads as a valid but wrong weight, which is the failure mode that gets a scale recalled. The burnout current source injects a known current into the input so an open bridge drives the reading to full scale instead of to zero, and the reference detect function flags a reference that has failed rather than silently converting against a floating node. The low side power switch removes the bridge from the supply between readings, which is what allows a battery instrument to average microamps when it is asleep. None of these appear in a headline specification, and all of them are why the part is specified for instrumentation rather than for general purpose capture.

Choosing between 4.17 Hz and 470 Hz

The noise scales roughly with the square root of the bandwidth, so the four times faster rate costs 2.4 times the noise at 16.7 Hz, and the fastest rate is much noisier again. A weight measurement that only needs a reading every quarter second should stay at the bottom of the rate range, and the 240 ms conversion time is then a feature rather than a delay. A process controller that needs a scan every few milliseconds accepts the noise and averages in software. The simultaneous rejection of 50 and 60 Hz is worth pointing out because the alternative is a filter notch at one frequency and an output rate chosen to avoid the other, which is a constraint that follows the product all the way to the enclosure.

Selection notes

  • Three differential inputs suit a bridge plus a thermistor plus a supply monitor, with the internal sequencer not present on this part, so the channel is selected by register.
  • The internal oscillator removes a crystal, and the 50 and 60 Hz rejection depends on it being accurate, which is why an external clock is offered as an option.
  • 380 uA at 5 V is 1.9 mW, low enough for a loop powered transmitter only if the rest of the chain is equally frugal.
  • The programmable digital outputs can drive a multiplexer or a bridge excitation switch without extra logic.

Questions buyers ask

How many true bits does a 24-bit part give at 4.17 Hz? About 17.7 noise free bits with a 2.5 V reference and a gain of 64, from 178 nV of peak to peak noise against a 39.06 mV full scale.

Can it measure a thermocouple directly? The instrumentation amplifier and the burnout current make an open sensor detectable, but a thermocouple needs cold junction compensation and a bias network, so it is an application question rather than a converter question.

Instrumentation chain options are grouped under ADC and DAC cross reference, and parts for patient connected equipment are collected in medical device components.

Request Quote — In Stock, 100% New & Original, Full Warranty