Contact Us

AD7794BRUZ-REEL

Brand: Analog Devices
Analog Devices AD7794BRUZ-REEL is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7794BRUZ-REEL — Analog & Mixed-Signal ICs | Superb Automation

AD7794BRUZ-REEL

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7794BRUZ-REEL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

AD7794BRUZ-REEL: 40 nanovolts is 0.13 of a 24 bit count

The AD7794 is a six channel, 24 bit sigma delta converter with the instrumentation amplifier, the reference and the excitation current sources all on the die, in a 24 lead thin small outline package. It is the part that sits directly behind a bridge, a thermocouple or a strain gauge, where the signal is tens of millivolts and the noise floor decides whether the last three digits of a display mean anything. Its update rate runs from 4.17 Hz to 470 Hz and its supply current is 400 microamps, which is why it turns up in battery powered instruments rather than in bench equipment.

What the vendor page states

ParameterValue
Resolution24 bit, up to 23 effective bits
RMS noise40 nV at 4.17 Hz, 85 nV at 16.7 Hz
Update rate4.17 Hz to 470 Hz
Inputssix differential, with a low noise programmable gain amplifier
Referenceinternal band gap, 4 ppm per C typical, plus two external reference inputs
Rejectionsimultaneous 50 Hz and 60 Hz
Extrasprogrammable current sources, burnout currents, bias voltage generator, low side power switch, reference detect
Supply current400 microamps typical, 1 microamp maximum in power down
Supply range2.7 V to 5.25 V
Package and grade24 lead TSSOP, minus 40 to plus 105 C, with a C grade to plus 125 C

The same noise figure read three ways

Forty nanovolts rms against a 5 V full scale is 0.008 ppm, which is 0.13 of a 24 bit count. At 16.7 Hz the 85 nV is 0.285 of a count. Read this way the converter's own quantisation is coarser than the analogue noise, and the 23 effective bit claim is simply the peak to peak version of the same arithmetic: six and a half sigma of 40 nV is 264 nV, and 5 V divided by that is 1.89 x 10 to the 7 counts. The picture changes as gain goes up and the full scale comes down. At a gain of 8 the count is 37.25 nV and 40 nV of noise is 1.07 counts, at a gain of 32 it is 4.29 counts, and at a gain of 128, where the full scale is 39 mV, the count is 2.33 nV and the same noise is 17.18 counts. That last number is what a load cell sees, and it is the reason the slow rate exists.

Update rate and the mains notches

At 4.17 Hz one conversion takes 239.8 ms, at 16.7 Hz it takes 59.88 ms, and at 470 Hz it takes 2.13 ms. The simultaneous 50 and 60 Hz rejection is tied to specific rates: 16.7 Hz gives three samples per 50 Hz cycle and four per 60 Hz cycle, which is why that rate is the default in weigh scale work. At 470 Hz the conversion is faster than a mains cycle and the rejection is gone, so a system that needs both speed and rejection has to pick which one it is giving up.

Where the drift actually comes from

The internal reference drifts 4 ppm per degree, so a 100 degree excursion is 400 ppm, which is 1 mV on a 2.5 V reference. That is four orders of magnitude larger than the 40 nV of noise. A buyer who is chasing the last digit should compare the reference drift against the noise before ordering, because the converter is not the limiting element in a system that runs over temperature. For anything above 105 C the C grade is the only option, and the six channels share one 400 microamp budget, which is 66.7 microamps per channel at 2.7 V for 1.08 mW in total.

Before the order goes out

The low side power switch lets a bridge be powered down between conversions, which matters more than the converter current when the bridge itself draws milliamps. The converter cross reference lists the pin compatible and functionally similar sigma delta parts by channel count, the lead time page is the place to check when this package is on allocation, and the analog and mixed signal category page holds the rest of the precision converter family.

Request Quote — In Stock, 100% New & Original, Full Warranty