Contact Us

AD7780BRUZ

Brand: Analog Devices
Analog Devices AD7780BRUZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7780BRUZ — Analog & Mixed-Signal ICs | Superb Automation

AD7780BRUZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7780BRUZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7780BRUZ: A Bridge Front End That Trades Rate for Noise, 10 Hz at a Time

The AD7780 is a complete front end for bridge sensors: a 24-bit sigma-delta converter, a low noise programmable gain amplifier with settings of 1 and 128, an internal oscillator and a bridge power-down switch, all in a 16-lead TSSOP or a narrow body 14-lead SOIC. Every configuration pin is a logic level rather than a register write, so the part has no configuration bus at all and the serial port is read only. That is deliberate: on a weigh scale the host has one job, which is to read the weight, and a part that cannot be misconfigured by firmware is a part that cannot be bricked by a bad register write.

Two output rates, and what each one costs

The update rate is 10 Hz or 16.7 Hz, selected by a pin, and the filter response is selected with it. At 16.7 Hz the filter gives better dynamic performance and a settling time of 120 ms. At 10 Hz the filter gives more than 45 dB of stop band attenuation and a settling time of 300 ms, and that attenuation is specifically useful against low frequency mechanical vibration of a load cell, which is the disturbance that makes a scale reading flicker while a truck idles next to it. Simultaneous 50 Hz and 60 Hz rejection is available at both rates, so a scale built for one market does not need a different filter setting when it ships to another.

Noise stated in nanovolts and in bits

At a gain of 128 the full scale differential input is plus or minus 39 mV, so one 24-bit code is 4.65 nV. The specified rms noise is 44 nV at 10 Hz and 65 nV at 16.7 Hz, which is about 9.5 codes and 14 codes respectively, and the peak to peak resolution is quoted as 17.6 bits at 10 Hz and 17.1 bits at 16.7 Hz. At a gain of 1 the full scale is plus or minus 5 V, the rms noise is 2.4 uV at 10 Hz and 2.7 uV at 16.7 Hz, and the peak to peak resolution is 18.8 bits and 18.7 bits. The higher bit count at unity gain is not a better measurement, it is a different span: the same absolute noise spread over a 5 V range is a smaller fraction of it. In a bridge application the gain of 128 setting is the one that matters, because the bridge output is a few millivolts at most.

ParameterGain of 128Gain of 1
Full scale differential inputPlus or minus 39 mVPlus or minus 5 V
RMS noise at 10 Hz44 nV2.4 uV
RMS noise at 16.7 Hz65 nV2.7 uV
Peak to peak resolution at 10 Hz17.6 bits18.8 bits
Peak to peak resolution at 16.7 Hz17.1 bits18.7 bits
Settling time at 10 Hz300 ms300 ms
Settling time at 16.7 Hz120 ms120 ms
Supply current330 uA115 uA
Supply range2.7 V to 5.25 V2.7 V to 5.25 V
TemperatureMinus 40 C to plus 105 CMinus 40 C to plus 105 C

The bridge power-down switch and the status pin

The internal bridge power-down switch lets the host remove excitation from the load cell between readings, which is the only way a battery powered scale reaches a multi year cell life: the bridge itself draws far more than the converter, and it is only needed for the 300 ms before a reading. The status function reports whether the last conversion was valid, so firmware can discard a reading taken while the bridge was still settling instead of averaging it into the result. The internal oscillator removes the crystal from the BOM, at the cost of a clock that is specified as part of the converter rather than as a separate component.

Where it fits

Weigh scales, pressure measurement, industrial process control and portable instrumentation are the named applications, and the part is at its best where a bridge is the sensor and the reading has to be stable rather than fast. A system that needs more than 16.7 updates per second, several channels, or an external amplifier between the bridge and the converter should move up the family to a multiplexed front end with software programmable rates. To compare those options, the ADC and DAC cross reference page lists the family members, the medical device components page covers the qualification requirements for instrument builds, and the ADI part second source page covers alternatives if the code is allocated.