Contact Us

AD7714ANZ-5

Brand: Analog Devices
Analog Devices AD7714ANZ-5 is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7714ANZ-5 — Analog & Mixed-Signal ICs | Superb Automation

AD7714ANZ-5

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7714ANZ-5 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7714ANZ-5: A 24-Bit Front End Whose Noise Figure Cannot Be Read Without the Gain

The AD7714 is a complete low frequency analogue front end: a programmable gain amplifier with settings from 1 to 128, a charge balancing sigma-delta modulator, a digital filter and a three wire serial port, in front of a converter specified at 24 bits with no missing codes. This order code is the 5 V version in the 24-pin 0.3 inch plastic dual in line package, specified from minus 40 C to plus 85 C. It is not a general purpose converter: it is aimed at slow, small signals from transducers, where the signal arrives at a few millivolts and the job is to convert it without adding conditioning stages.

Five inputs, three of them differential

Six analogue pins provide either three fully differential input channels or five pseudo differential channels, and a separate differential reference input means the reference can be driven by the same ratiometric bridge supply as the signal. That last point decides accuracy in weigh scale work: when the bridge excitation and the converter reference are the same voltage, the excitation drift cancels instead of appearing in the reading, and the remaining error comes from the amplifier and the filter rather than from the supply. The gain of 1 to 128 is applied ahead of the modulator, so the small signal is amplified before it reaches the conversion, which is why a 10 mV bridge output can be resolved without an external instrumentation amplifier.

The noise number and the code it corresponds to

The part is specified with less than 150 nV rms of noise. On its own that figure is not usable, because at 24 bits the value of one code depends entirely on the full scale it is referred to. With a 2.5 V reference, one code is 149 nV, so the noise is about one code at unity gain and the 24-bit word is full of real information only near the bottom of the range. At a gain of 128 the input span falls to about 19.5 mV, one code becomes 1.16 nV, and the same 150 nV of noise is about 129 codes, which is 17 bits of usable resolution rather than 24. The vendor's specification pairs the noise with a gain and a filter setting for exactly this reason, and an evaluation that quotes 24 bits without those two conditions is quoting the wrong number.

ParameterValueWhat it decides
Resolution24 bits, no missing codes149 nV per code on a 2.5 V reference
Nonlinearity0.0015 percentAbout 393 codes at 24 bits, well above one code
InputsThree differential or five pseudo differentialOne part for a five channel transducer board
Gain1 to 128 in binary steps19.5 mV of input span at a gain of 128 on 2.5 V
NoiseLess than 150 nV rmsOne code at unity gain, 129 codes at a gain of 128
Supply current350 uA typical1.75 mW at 5 V for the whole front end
Power-down5 uA typical, 15 uW quoted15 uW matches 5 uA at 3 V, not at 5 V
FilterProgrammable first notch and settling timeLine rejection where the notch is placed
CalibrationSelf, system and background, registers readableOffset and gain error removed in the field
Supply5 V, minus 40 C to plus 85 CThe 3 V grades reach plus 105 C, this one does not
Package24-pin 0.3 inch plastic DIPThrough hole assembly, socket friendly

The filter is the throughput control, not the clock

In a sigma-delta converter the output rate and the rejection are the same decision. The first notch of the on-chip digital filter is programmable through the control register, and moving it shifts both the filter cutoff and the settling time, so a product that needs 50 Hz and 60 Hz rejection places the notch there and accepts the resulting output rate. The device is production tested with a 2.4576 MHz master clock and guaranteed to operate down to a 400 kHz clock, which gives a slow but very quiet mode for battery instruments. Two details of the clock path cause real support cases: the clock must be present whenever the part is not in standby, because a missing clock can make the device draw more current than specified and lose its calibration, and at gains of 8 and above with the 2.4576 MHz clock the BST bit in the filter high register has to be set.

Calibration and the register bank

The part supports self calibration, system calibration and background calibration, and it lets the host read and write the on-chip calibration registers. Self calibration removes the internal offset and gain error, system calibration removes the error of the whole signal chain including the external transducer and its reference, and background calibration repeats the correction while conversions continue so that drift is tracked without interrupting the data stream. System calibration is the one that matters in a weigh scale, because the error of the load cell and its wiring is larger than the error of the converter, and it is also the one that has to be repeated whenever the mechanical assembly changes.

Typical uses are portable industrial instruments, portable weigh scales, loop powered systems and pressure transducers, all of which run from a single supply and need a front end that does not cost more current than the sensor. For a build that mixes this converter with other ADI front ends, the ADC and DAC cross reference page lists comparable parts, the medical device components page covers the qualification side for instrument builds, and the component obsolescence management page covers what to do when an order code in this family is withdrawn.