Product Specifications

AD7705BRZ — Analog & Mixed-Signal ICs | Superb Automation

AD7705BRZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7705BRZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7705BRZ: Two Differential Channels, 16 Bits and One Milliwatt

The AD7705 is a complete analog front end for low frequency measurement: two fully differential input channels, a programmable gain amplifier with gains from 1 to 128, a sigma delta modulator with a digital filter, and a three wire serial interface that is SPI, QSPI, MICROWIRE and DSP compatible. It delivers 16 bits with no missing codes and 0.003 percent nonlinearity, runs from 2.7 V to 3.3 V or 4.75 V to 5.25 V, dissipates 1 mW maximum at 3 V, drops to 8 uA in standby, and comes in a 16-lead PDIP, SOIC or TSSOP. Output update rates run from 20 Hz to 500 Hz, and the digital filter notches at 50 Hz and 60 Hz.

One milliwatt at 3 V is 333 uA for the whole front end

A complete measurement channel that draws 333 uA at 3 V is the reason this part exists: the modulator, the programmable gain amplifier, the digital filter and the reference interface all fit inside that current, so a battery instrument can run a bridge or a thermocouple for years. The standby current of 8 uA is two orders of magnitude below the active current, which makes a duty cycled measurement cheap: a reading every second costs almost nothing in average current, and a reading every millisecond costs the full 333 uA.

Gain 128 puts a 20 mV signal into a 16-bit word

At a gain of 128 with a 2.5 V reference the full scale input is about 19.5 mV, so one code is 298 nV. A load cell with a 2 mV per volt sensitivity on a 5 V excitation produces 10 mV at full load, which is half of that range, and the resolution is then 298 nV, or 30 parts per million of the load. The nonlinearity of 0.003 percent of full scale is 600 nV at that range, which is two codes, so the amplifier and the modulator are matched to each other and the limit becomes the reference and the thermal noise of the bridge itself.

ParameterValueWhat it decides
ChannelsTwo fully differentialTwo independent bridges or one bridge plus a temperature
Resolution16 bits, no missing codes298 nV per code at a gain of 128
Nonlinearity0.003 percentAbout two codes at the highest gain
Gain range1 to 12820 mV full scale at the top of the range
Update rate20 Hz to 500 HzThe trade between noise and response time
Filter notches50 Hz and 60 HzMains rejection on both line frequencies
Power1 mW maximum at 3 V333 uA for the entire front end
Standby8 uA maximumDuty cycled measurement at negligible cost
Supply2.7 to 3.3 V or 4.75 to 5.25 VTwo rails, not a continuous range
ReferenceExternal, differentialRatiometric measurement with the bridge supply
Input bufferSelectableA buffer for a high impedance source, bypassed for a low one
InterfaceThree wire serial, Schmitt clock inputDirect connection to a slow host
Package16-lead PDIP, SOIC or TSSOPThe PDIP option for legacy boards

Ratiometric measurement and the reference

If the bridge and the converter reference are fed from the same supply, the reading is the ratio of the bridge output to that supply, and the supply tolerance cancels. That is the standard arrangement for a load cell and it is why the part has a differential reference input: the reference can be the bridge excitation itself, measured at the bridge, so the cable drop is included in the ratio rather than appearing as an error. A board that uses a fixed reference instead loses the cancellation and has to specify the excitation supply to the accuracy of the measurement.

The 20 Hz update rate and the noise trade

At 20 Hz the digital filter averages long enough that the input referred noise is a small fraction of a code, and at 500 Hz the same converter is much noisier. The two numbers that matter are the noise at the chosen rate and the settling time after a channel change, because the filter has to fill before the reading is valid. A common mistake is to switch channels and read immediately: the first readings after a switch belong to the previous channel blended with the new one, and the number of readings to discard is a function of the filter order and the update rate.

Buffered and unbuffered input

The input buffer can be switched in or out. With the buffer in, the input impedance is high and a resistive source such as a thermistor divider can drive it directly, at the cost of the buffer's own offset and noise. With the buffer out, the switched capacitor input draws a transient from the source, so the source impedance has to be low and the gain has to be high enough that the transient is small. Choosing the wrong setting is a common cause of a reading that changes when the source resistance changes, which looks like a converter fault and is a configuration error.

Sourcing a low frequency measurement front end

The order code fixes the package, and the three package options are electrically identical, so a board change between them is a footprint change only. Parts that combine a programmable gain amplifier with a sigma delta converter can be compared through ADC DAC cross reference, the instrument side of the bill of materials is covered in OEM procurement, and the route for a discontinued measurement part is in obsolete part cross reference hub.