AD7366BRUZ-RL7
Product Specifications
AD7366BRUZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD7366BRUZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD7366BRUZ-RL7: Two 12 Bit Converters That Sample at the Same Instant
What this part is
The AD7366 contains two successive approximation converters on one chip, each preceded by a two channel multiplexer, so four single ended inputs reach two converters that sample and convert together. The analog inputs are true bipolar, which means a negative voltage goes straight in without an offset network: the part accepts plus and minus 10 V, plus and minus 5 V and 0 V to 10 V ranges, and plus and minus 12 V when a 3 V external reference is applied. That is the reason this converter appears in industrial equipment where the sensor front end already runs on plus and minus 15 V rails.
The throughput rate is 1 MSPS and a simultaneous conversion with the result read back takes under 1 us. The on chip reference is 2.5 V with 0.2 percent accuracy and can be disabled when an external one is wanted. Current consumption is 8.3 mA in normal operation and 320 nA in shutdown, and the part is specified from minus 40 to plus 85 degrees C.
Published figures that matter to a buyer
| Resolution | 12 bit, no missing codes |
| Converters | 2, with a 2 channel multiplexer in front of each |
| Analog inputs | true bipolar, 4 single ended channels |
| Input ranges | plus and minus 10 V, plus and minus 5 V, 0 V to 10 V |
| Extended range | plus and minus 12 V with a 3 V external reference |
| Throughput | 1 MSPS |
| Simultaneous conversion and read | under 1 us |
| Signal to noise | 72 dB at 50 kHz input |
| Reference | 2.5 V, 0.2 percent, can be disabled |
| Supply current | 8.3 mA normal, 320 nA shutdown |
| Temperature | minus 40 to plus 85 degrees C |
| Interface | serial, SPI and DSP compatible |
Where the headline numbers stop
Twelve bits across a 20 V span puts one count at 4.88 mV, and across a 10 V span at 2.44 mV. Seventy two decibels of signal to noise at a 50 kHz input works out at 11.7 effective bits, so the last half bit of the 12 is not usable in a single sample and averaging is what recovers it. The reference error of 0.2 percent on 2.5 V is 5 mV, which is one count on the 20 V span: the reference is not the limiting term, but it is right at the edge of one count and any additional error budget has to come from elsewhere.
The 8.3 mA at 5 V is 41.5 mW for two converters running at 1 MSPS, which is why the shutdown state matters in a battery instrument that samples in bursts. The conversion and read time of under 1 us against a 1 MSPS period of 1000 ns means the interface is busy for essentially the whole period at full rate, so a processor that reads both results sequentially has to use the simultaneous sample and then take its time on the read, which is what the two result registers are for.
Applications where it fits
- Motor and inverter control where two phases must be sampled at the same instant to compute a vector.
- Industrial data acquisition on plus and minus 15 V rails, where a bipolar input removes the offset network.
- Power measurement that needs simultaneous voltage and current samples.
- Instrumentation with a 0 to 10 V sensor output and a requirement for no missing codes.
Two questions buyers ask
Is the 14 bit version the same part? The AD7367 is the 14 bit member of the same family with the same pinout and the same input ranges, offering 76 dB of signal to noise rather than 72 dB. It is a different order code and a higher price, and it drops into the same footprint. A board that is marginal on noise at 12 bits can move to the 14 bit part without a circuit change, which is often cheaper than reworking the analog front end.
How is the plus and minus 12 V range obtained? Only with a 3 V external reference applied to the reference pins, and only with supply rails that reach plus and minus 12 V. The internal 2.5 V reference does not support that range. The external reference then sets the accuracy of the whole channel, so its drift becomes the drift of the measurement and has to be specified as part of the converter error budget.
Sourcing notes and next step
AD7366BRUZ-RL7 is the surface mount body on tape and reel. The 14 bit member shares the footprint, and the family also includes parts with a different channel count, so a cross reference has to state the resolution and the number of simultaneous channels. The analog and mixed signal IC family page lists the converter line, the ADC and DAC cross reference page sets out the comparison fields, and the medical device components page covers the traceability a medical build needs from a converter supplier.
Request Quote — In Stock, 100% New & Original, Full Warranty