AD73360ARZ
Product Specifications
AD73360ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD73360ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD73360ARZ: six simultaneous 16-bit channels in one analogue front end
The AD73360ARZ is a six channel analogue front end in which all six 16-bit converters sample at the same instant, each with 77 dB of signal to noise ratio over a DC to 4 kHz band, a programmable gain amplifier from 0 to 38 dB in eight steps and a serial port that allows several parts to be cascaded. The sample rate is programmable to 64, 32, 16 or 8 kHz from a 16.384 MHz master clock, and the whole part draws 80 mW maximum from a 2.7 V supply.
Published values
| Parameter | Value |
|---|---|
| Channels | 6, simultaneous sampling |
| Resolution | 16 bits per channel |
| SNR | 77 dB over DC to 4 kHz, 12.5 effective bits |
| Maximum sample rate | 64 kS/s per channel |
| Aggregate throughput | 384 kS/s across six channels |
| Crosstalk | 83 dB |
| Group delay | 25 microseconds typical per channel |
| Gain | 0 to 38 dB in 8 programmable steps |
| Sample rates | 64, 32, 16, 8 kHz from a 16.384 MHz master clock |
| Reference | on chip, programmable for 3 V or 5 V operation |
| Supply | 2.7 V to 5.5 V single supply |
| Power | 80 mW maximum at 2.7 V |
| Interface | synchronous serial port, cascade capable |
| Package | 28-lead SOIC, also 44-lead TQFP |
Simultaneous sampling is the whole point
Six channels sampled at the same instant give a phase relationship that survives to the DSP unchanged. On a three phase meter that is what makes the power calculation correct at any power factor; sample the channels in sequence and the phase error appears as a reactive component that changes with load. The 25 microsecond group delay, common to all channels, is 0.45 degrees at 50 Hz and 0.54 degrees at 60 Hz, which is small enough to be calibrated out with one constant.
The 83 dB of crosstalk between channels is the second number that matters on a meter, because the voltage channel is at full scale while the current channel may be at one five hundredth of it. Crosstalk that is acceptable on a general purpose data logger shows up on a meter as an error that appears only at light load, which is exactly where the accuracy class is hardest to hold.
Gain steps and the low current end
Eight gain steps from 0 to 38 dB let a small shunt signal be lifted before the converter without an external amplifier. 38 dB is a factor of about 79, so a 1 mV shunt signal becomes 79 mV at the converter input, which is a usable fraction of the 16-bit range. The gain is set per channel by register, so the same board can serve a 5 A and a 100 A meter by firmware.
The cost of gain is headroom. At 38 dB a 30 mV signal reaches full scale, and a fault current will clip the channel. Clipping in a metering channel is not a small error: the samples above full scale are lost and the energy accumulates low. Where a meter has to survive a short circuit, the gain setting is chosen for the fault current and the resolution at light load is accepted as it is.
Cascading six channels into twelve
The serial port is built so that multiple devices can share a frame, which is how a 12 channel logger is built from two parts and one DSP port. The frame timing is set by the master clock and the port, and the usual integration failure is a second device whose frame sync arrives one bit late, producing channels that are interleaved by one sample.
The 80 mW maximum at 2.7 V is for the whole six channel part, so per channel it is under 14 mW. That power, with the on chip reference and no external amplifiers, is what makes a six channel front end fit inside the budget of a loop powered or battery backed instrument, where six separate converter channels plus their drive amplifiers would not.
For a board that has to keep running while a reel runs out, medical device components is where the family alternatives sit, one stop BOM sourcing is the check list before a substitute goes in, and BOM shortage recovery is how a gap is covered without a new line item.
Two questions buyers ask
Does the AD73360 include the anti alias filter? It includes the sigma delta modulator and the digital decimation, which set the band and the stopband attenuation, but the analogue RC in front of each input is still on the board. Its tolerance is part of the channel matching and should not be left to a generic value.