The AD7280AWBSTZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD7280AWBSTZ: 1.6 mV of Cell Accuracy Across a 27.5 V Common Mode
The AD7280A is a lithium ion battery monitoring system for stacked cells, with six cell voltage inputs and six auxiliary inputs, a 12 bit converter with a 1 us conversion time per channel, an input common mode range from 0.5 V to 27.5 V, and a cell voltage accuracy of 1.6 mV. The internal reference is specified at 3 ppm per degree Celsius, which is what makes that accuracy hold over temperature, and the part runs from an 8 V to 30 V supply with a power-down current of 1.8 uA. A single serial interface can address up to eight devices in a daisy chain, covering 48 cells.
Why the reference, not the converter, sets the accuracy
A 12 bit converter on a 5 V span has a code size of 1.2 mV, which is already comparable with the 1.6 mV total accuracy figure. The accuracy is achieved because the measurement is ratiometric against an internal reference that moves only 3 ppm per degree Celsius, and because the input multiplexer and the converter share the same reference. Over a 100 degree span the reference contributes 300 ppm, which on a 4 V cell is 1.2 mV, so a large part of the 1.6 mV budget is the reference drift and not the converter's own noise.
The 27.5 V common mode and the stacking problem
Each device sits at the potential of its own cell group, so the sixth device in a stack is measuring cells that are more than 100 V above ground. The common mode range of 0.5 V to 27.5 V is the range within one device's own group, and the isolation between devices is provided by the daisy chain interface and its capacitor or transformer barrier. That is why the part has a daisy chain interface rather than a parallel bus: a parallel bus would need one isolator per device.
| Parameter | Value | What it decides |
|---|---|---|
| Cell inputs | Six, plus six auxiliary | Six cells and six temperature or diagnostic points |
| Resolution | 12 bit | 1.2 mV per code on a 5 V span |
| Conversion time | 1 us per channel | Twelve channels in 12 us |
| Common mode range | 0.5 V to 27.5 V | Within one group of six cells |
| Cell accuracy | Plus or minus 1.6 mV | 0.044 percent of a 3.6 V cell |
| Reference drift | 3 ppm per degree C | 1.2 mV over 100 degrees on a 4 V cell |
| Supply | 8 V to 30 V | Runs from the stack it monitors |
| Power-down current | 1.8 uA | The state between measurement bursts |
| Daisy chain | Up to 48 channels per interface | Eight devices on one isolated link |
| Balancing | External FET interface per cell | Passive balancing with external resistors |
| Command protection | CRC on read and write | A corrupted cell address is detected |
| Alert output | Per device | An over or under limit does not need a poll |
| Package | 48-lead LQFP | Automotive qualified |
Balancing current is an external decision
The part provides the interface for cell balancing, but the current flows through external resistors and transistors chosen by the system. A 200 mA balance current into a 3.6 V cell dissipates 0.72 W in the resistor, and six cells balancing at once is 4.3 W inside a battery pack that is already warm. The monitor's accuracy is not affected by that current as long as the measurement is taken when the balance FET is off, which is why the sequencing of the two operations matters more than the parts.
Measuring while the pack is working
The 1 us conversion and the 12 us for a full scan of one device mean a complete 48 cell measurement takes about 100 us across the daisy chain, which fits between the switching edges of an inverter. Measuring during a switching transient would put the common mode movement into the reading, and the common mode rejection of the input multiplexer is specified for a settled input. The measurement window, not the converter's speed, is what determines whether the reading is usable in a running vehicle.
Buying a battery monitor for a pack
The comparison across candidates is cell count per device, accuracy against the reference drift, and the daisy chain topology, and the order code fixes the package and the qualification. A part with the same pin count and a less stable reference cannot meet the accuracy over temperature. Availability is tracked through ADC DAC cross reference, and the wider question of an electric vehicle bill of materials is set out in power management cross reference. Where the original code is short, the options are in component lead time solutions.