Contact Us

AD7124-4BRUZ-RL7

Brand: Analog Devices
Analog Devices AD7124-4BRUZ-RL7 is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7124-4BRUZ-RL7 — Analog & Mixed-Signal ICs | Superb Automation

AD7124-4BRUZ-RL7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7124-4BRUZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7124-4BRUZ-RL7: the reel code of the four channel 24-bit converter

The AD7124-4BRUZ-RL7 is the same 24-bit four channel converter as the tube code, supplied on reel for production. Everything in the electrical table is unchanged: three power modes, up to 22 noise free bits at a gain of 1, output data rates from 1.17 to 19200 samples per second, and simultaneous 50 and 60 hertz rejection at 25 samples per second. What a buyer has to confirm for a reel code is moisture sensitivity, reel quantity and the reflow profile, because those are the things that stop a line.

Published values

ParameterValue
Resolution24 bit
Inputs4 differential
Package24-lead TSSOP (RU-24)
PackingReel
Low power mode24 nV rms at 1.17 SPS, gain 128, 255 uA typical
Full power mode23 nV rms at 9.4 SPS, gain 128, 930 uA typical
Noise free resolutionup to 22 bits at gain 1
Output data rate1.17 SPS to 19200 SPS depending on mode
Mains rejectionsimultaneous 50 Hz and 60 Hz at 25 SPS
Supply2.7 V to 3.6 V analog, 1.8 V interface supply
Power down current5 uA maximum
Operating temperature-40 C to +125 C

Reel handling for a 24-lead TSSOP

A 24-lead TSSOP is a fine pitch package and the reel is the format that keeps it out of handling until the placement head picks it. The two things that go wrong are the moisture barrier bag being opened too early and the parts sitting on a feeder over a weekend, and the reel quantity not matching what the line consumes in one setup.

The correct sequence is to check the moisture sensitivity level on the bag label, follow the floor life stated for that level, and bake only if the floor life has been exceeded. A part that is baked when it did not need to be is not damaged, but a part that is not baked when it needed to be will show delamination after reflow and that is a batch level failure.

The interface supply is a separate pin

The analog supply is 2.7 to 3.6 volts and the interface supply is 1.8 volts, which means the converter can sit on a 3.3 volt analog rail and talk to a 1.8 volt processor without a level shifter. That saves components and it also means the two rails have to come up in an order the part tolerates. A board that brings up the interface rail first and the analog rail 100 milliseconds later will sometimes read a configuration that was never written.

The power down current is 5 microamps maximum, so a channel that is scanned once a minute can be powered down between conversions. The settle time after power up then becomes part of the scan period, and it has to be measured on the actual board rather than taken from a typical curve.

Where the four channels are not enough

Four differential inputs cover a four wire RTD plus a cold junction sensor, or four thermocouples with a shared cold junction. A fifth channel needs either a second part or the eight channel member of the same family, and the eight channel member shares the register map, so the code can be reused but not the footprint. That is worth knowing before a board revision, not after.

Channels are scanned by an automatic sequencer with per channel configuration, so four channels of different sensor types can run at different gains and different filter settings without the host rewriting registers between conversions.

For a board that has to keep running while a reel runs out, the ADI second source page is where the family alternatives sit, one stop BOM sourcing is the check list before a substitute goes in, and component lead time solutions is how a gap is covered without a new line item.

Two questions buyers ask

Does the reel code differ electrically from the tube code? No. Same die, same 24 bit converter, same three power modes. The difference is packing and the handling rules that come with it.

Does the 1.8 volt interface supply have to come up first? The order has to be one the part tolerates, and a configuration written before the analog rail is stable can be lost. The sequence should be verified on the board rather than assumed.