AD71056ARZ
Product Specifications
AD71056ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD71056ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD71056ARZ: single phase energy metering with the oscillator on chip
The AD71056ARZ is a single phase energy metering IC that measures active power from a shunt and delivers it as a pulse train on F1 and F2, with a higher frequency CF output for calibration. The oscillator is on chip, so the meter needs no crystal, and the published accuracy is better than 0.1 percent over a 500 to 1 dynamic range, which meets the IEC 62053-21 requirement the part is written against. It runs from a single 5 V supply at 20 mW.
Published values
| Parameter | Value |
|---|---|
| Measurement | active power, average, on F1 and F2 pulse outputs |
| Accuracy | better than 0.1 percent over 500 to 1 dynamic range |
| Standard | IEC 62053-21, 50 Hz and 60 Hz |
| Calibration output | CF, instantaneous real power |
| Reverse indication | REVP logic output for miswiring or export |
| Reference | 2.45 V on chip, 20 ppm per degree C typical, can be overdriven |
| Oscillator | on chip, no crystal or resonator needed |
| Supply monitor | inactive below about 4 V on VDD |
| No load threshold | on chip creep protection |
| Phase matching | internal, with a high pass filter on the current channel |
| Supply | single 5 V, 20 mW typical, 4 mA |
| Package | 16-lead narrow body SOIC |
The oscillator is the cost story
A crystal, its two load capacitors and the routing that keeps them quiet are three BOM lines and a tuning step at production. Moving the oscillator on chip removes all of it, and it also removes the failure mode where a meter reads a few percent low because the crystal was loaded wrong. On a meter built in volume the saving is not the component cost, it is the calibration station that is no longer needed for frequency.
The trade is that the on chip oscillator is set when the part is built and cannot be trimmed, so the accuracy of the time base is whatever the part publishes. For a Class 2 meter that is enough; for a billing meter that has to hold its class over fifteen years the drift of the reference and of the oscillator is part of the type approval, and both are on the data sheet.
500 to 1 dynamic range in practice
A 500 to 1 range means the meter holds its 0.1 percent error from the rated current down to a five hundredth of it. That is where a cheap meter fails: at low current the shunt signal is micro volts and the ADC offset dominates. The high pass filter in the current channel exists to remove the DC offset that would otherwise integrate into a false energy reading, and the no load threshold stops creep when the load is disconnected.
The 2.45 V reference drifts 20 ppm per degree C typically, which over a 40 degree swing is about 1.96 mV, or 0.08 percent of the reference. That figure belongs in the same sentence as the 0.1 percent accuracy claim, because the two add up over the temperature range a meter sees on an outside wall.
Wiring, reverse power and the supply monitor
The REVP output flags negative power, which in a domestic meter usually means the current channel is connected backwards rather than that the customer is exporting. Putting that pin on a service LED has saved more site visits than any accuracy improvement, because it separates a wiring error from a metering error at the first power up.
The supply monitor holds the part inactive below about 4 V and drives the outputs to their inactive state, so a brown out does not produce a burst of pulses that the counter then keeps. On a meter with an electromechanical register that pulse burst is permanent, which is why the monitor is a functional requirement and not a nicety.
Where a customer needs a second position on this part, the power management cross reference is the starting point, component obsolescence management sets out the checks a substitution has to pass, and OEM procurement is the short lead time route we quote against.
Two questions buyers ask
Does the AD71056 need a calibration step in production? Yes, the gain of the meter is set against a reference load once, using the CF output. Having the oscillator on chip removes the frequency calibration, not the gain calibration.
Can the internal reference be overdriven? The data sheet allows an external reference to drive the pin where the application needs a better drift figure or a different value, and that is the option to quote when a customer's type approval demands it.