AD629ARZ
Product Specifications
AD629ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD629ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD629ARZ: Gain of One, 270 V of Common Mode and Input Protection Built In
The AD629ARZ is a difference amplifier with a fixed gain of one and a common mode input range that reaches beyond 270 V on plus and minus 15 V supplies, which puts it in the class of parts that replace an isolation amplifier where galvanic isolation is not actually required. The inputs are protected against common mode and differential overvoltage, the supply current is 1 mA maximum, and the small signal bandwidth is 500 kHz. Because the gain is fixed at one, the whole error budget is offset, gain error and common mode rejection, with no external resistor ratio to add drift. The part is aimed at battery cell voltage monitoring, supply current monitoring, motor control and any node where a measurement amplifier has to sit on top of a high voltage rail.
Published values
| Parameter | Value |
|---|---|
| Nominal gain | 1 V per volt, fixed |
| Common mode range | Beyond 270 V with plus and minus 15 V supplies |
| Input protection | Common mode and differential overvoltage on the inputs |
| Supply current | 1 mA maximum |
| Bandwidth | 500 kHz |
| Common mode rejection | 86 dB minimum at 500 Hz on the B grade |
| Gain nonlinearity | 3 ppm maximum on the B grade |
| Bodies | 8-lead DIP and 8-lead surface mount, die also listed |
| Typical applications | Battery cell monitors, supply current monitors, motor control, isolation replacement |
What a fixed gain of one buys in a cell monitor
A stack of series cells can sit 300 V above the chassis, and the monitor has to measure each cell to a few millivolts while its own ground moves. A gain of one amplifier with a 270 V common mode window lets the measurement chain sit at the cell potential and pass a low voltage difference to a converter that is referenced to the same node, so no divider ratio error enters the reading. The input protection matters more than the number suggests: a service technician disconnecting a cell tap while the amplifier is powered puts a transient across the inputs, and a part without protection fails short and takes the whole monitor down.
Where the isolation amplifier is still the right answer
The data sheet is direct about when not to use this part: circuits that need galvanic isolation still need an isolation amplifier, because a difference amplifier only rejects common mode up to the point where its own input stage breaks down. In a 400 V traction system the working voltage is above the 270 V window and the safety requirement is isolation rather than rejection. The boundary is worth stating to a buyer early, because the two parts sit at very different price points and a wrong first choice is expensive at both ends: too little common mode range fails qualification, and an isolation amplifier where a difference amplifier would do triples the component cost.
The A grade in practice
The features list in this data sheet quotes the B grade figures, 3 ppm of gain nonlinearity and 86 dB of common mode rejection at 500 Hz, and the specification table carries a separate column for the A grade with wider limits. A program that only needs the common mode range can take the A grade and absorb the difference in calibration; a program that measures a 5 mV cell voltage inside a 300 V stack cannot, because the rejection figure is the measurement. Reading which column a quoted number comes from is the whole exercise here, and it is the reason we ask for the grade and not only the family when a BOM is being priced. The amplifier cross reference lists the difference amplifier families we can supply, the ADI second source page covers grade equivalence inside this family, and the incoming inspection plan sets out how we check a batch before it ships.