AD628ARZ
Product Specifications
AD628ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD628ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD628ARZ: A Difference Amplifier Whose Gain Can Go Below One
The AD628ARZ is a high common mode voltage difference amplifier with a programmable gain, and the unusual part is the bottom of the range: the gain equation published in the data sheet is G equals 0.1 times the quantity 1 plus REXT1 over REXT2, and the guaranteed range runs from 0.11 to 100 V per volt. A gain below one is exactly what a high side shunt needs when the shunt voltage is tens of volts and the converter behind it accepts two and a half. The input pair is preceded by an internal divider that attenuates by ten before the difference stage, so a plus or minus 120 V common mode lands inside the amplifier's own supply window. The part runs from a single supply of 4.5 V to 36 V, which means the same device covers a 5 V logic rail system and a 24 V industrial bus.
Published values
| Parameter | Value |
|---|---|
| Gain equation | G equals 0.1 times 1 plus REXT1 divided by REXT2 |
| Gain range | 0.11 to 100 V per volt, guaranteed |
| Supply range | 4.5 V to 36 V, single supply |
| Common mode rejection | 75 dB minimum, dc to 500 Hz, gain of 1 |
| Input structure | Internal 100 k and 10 k divider, 10 to 1 attenuation ahead of the difference stage |
| Filter pin | CFILT, sets the feedback pole with an external capacitor |
| Gain setting pins | REXT1 and REXT2, two external resistors |
| Applications in the data sheet | High voltage current shunt sensing, power supply monitoring, motor control |
| Body | 8-lead surface mount, R suffix |
Why attenuation before amplification is the safe order
A 48 V bus with a 1 milliohm shunt produces 48 mV at full load, and the amplifier has to survive a short circuit on that bus without a divider in front of it. Placing the ten to one divider first means the difference stage sees 4.8 V of common mode at the worst case, well inside a 5 V supplied amplifier's window, and the fault current path is a resistor rather than a semiconductor junction. The cost is noise: the divider attenuates the signal before the amplifier's own noise is added, so the input referred noise figure is set by the divider ratio. For a shunt signal that is already millivolts this is acceptable, and it is the reason this topology is standard in motor drive and battery management current sense circuits rather than in low level sensor work.
Setting a gain below one on purpose
With REXT1 open and REXT2 fitted the gain sits at its floor of 0.11, so a bus voltage of 40 V maps to 4.4 V and fits a 5 V converter, which is the supply monitoring case in the data sheet. Adding REXT1 raises the gain toward 100 for shunt work. Because the equation is a ratio, the absolute resistor values only have to be stable relative to each other, and the CFILT capacitor sets a pole that rolls off the switching noise of the bus without loading the source. Programs that need a defined bandwidth should pick CFILT from the published transimpedance curve rather than from a rule of thumb, because the pole moves with gain.
Grade and body questions when this part goes short
Only the A grade exists for most order codes in this family, so substitution usually means a different amplifier topology rather than a different grade. A high common mode difference amplifier can be replaced by an isolation amplifier when galvanic isolation is needed, by a current sense amplifier when the common mode stays under 80 V, or by an instrumentation amplifier plus a divider when accuracy matters more than common mode range. Each of those changes the error budget, so the comparison has to be done on the specification rather than on the pinout. The amplifier cross reference lists the difference amplifier families we supply, the pin to pin cross reference covers the footprint question, and the drop in replacement guide sets out the checks before a topology change is accepted.