AD623ARZ-R7
Product Specifications
AD623ARZ-R7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD623ARZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD623ARZ-R7: a single supply instrumentation amplifier with rail to rail output and a gain of 1 to 1000
What this order code is
AD623ARZ-R7 is an instrumentation amplifier that runs from 2.7 V to 12 V single or dual supplies, sets any gain from 1 to 1000 with one external resistor, and swings its output rail to rail. The input common mode range extends 150 mV below ground on a single supply, so a shunt or a thermocouple that sits at ground can be amplified without a negative rail. The quiescent current is 550 microamps maximum, which is what makes it usable in battery and loop powered instruments.
The dc performance is a gain error of 0.10 percent at unity gain and 0.35 percent at gains above one, with 35 nV per root hertz of input referred noise at 1 kHz. The ac performance is 800 kHz of bandwidth at unity gain and 20 microseconds of settling to 0.01 percent at a gain of 10. With no external resistor the part is at unity gain, so the gain resistor is the only component between the sensor and the converter in most channels.
Parameters as published
| Item | Value |
|---|---|
| Gain range | 1 to 1000, one external resistor |
| Supply range | 2.7 V to 12 V single or dual |
| Output swing | rail to rail |
| Input range, single supply | 150 mV below ground |
| Quiescent current | 550 microamps maximum |
| Gain error at a gain of 1 | 0.10 percent |
| Gain error above a gain of 1 | 0.35 percent |
| Input noise at 1 kHz | 35 nV per root hertz |
| Bandwidth at a gain of 1 | 800 kHz |
| Settling to 0.01 percent at a gain of 10 | 20 microseconds |
| Common mode rejection | constant up to 200 Hz |
| Body | 8-lead industry standard pinout |
Numbers that decide the application
The bandwidth divides with gain in the usual way: 800 kHz at unity gain, 80 kHz at a gain of 10 and 8 kHz at a gain of 100. A bridge signal at a gain of 100 is therefore limited to about 8 kHz, which is enough for a weigh scale and not enough for vibration analysis. The noise follows the same path: 35 nV per root hertz over a 10 kHz band is 3.5 microvolts referred to the input, and at a gain of 100 that becomes 350 microvolts at the output, so a 12 bit converter on a 2.5 V range with a 610 microvolt step sees about half a bit of noise at the output.
The gain error is the term that catches people because it scales with the signal. At 0.35 percent of reading, a 100 mV input at a gain of 100 produces 10 V nominal and an error of 35 mV, which is 57 least significant bits of a 12 bit converter on 2.5 V. This is not a trimming problem, it is a specification to work around: a system that needs absolute accuracy either calibrates at the gain used or moves to a part with a lower gain error. The constant common mode rejection up to 200 Hz is the reason the part rejects mains hum so well in a bridge application.
The 550 microamp maximum is what allows the amplifier to run from the same 24 V loop supply as the rest of a 4 to 20 mA transmitter, where the current budget is the constraint. At 3 V the part dissipates 1.65 mW, and the input range 150 mV below ground means the shunt on the low side of a load can be measured directly, with the common mode at ground rather than at the rail.
Where it fits and where it does not
It fits low power medical instrumentation, transducer interfaces, thermocouple amplifiers, industrial process control and low power data acquisition. It does not fit a channel that needs better than 0.35 percent gain accuracy without calibration, a signal above about 8 kHz at a gain of 100, or a supply above 12 V, since the part is a 12 V maximum device and the 24 V industrial parts are in a different family.
Supply and second source questions
The questions we get are about the gain resistor, the gain error at the gain actually used and the supply ceiling, and about whether a pin compatible instrumentation amplifier from another vendor will hold the 150 mV below ground input range. That input feature is not universal on 8-lead instrumentation amplifiers, and a substitute without it will clip a ground referenced shunt. The instrumentation amplifiers we hold are listed on the amplifier cross reference page.
Sourcing notes and next step
We quote this code against the bill of materials and check the body, the packing and the gain resistor value, because the resistor is part of the channel tolerance and is often a different supplier's line. Where the exact code is short we will say so rather than offer a wider supply part as an equivalent. Send the line items, quantities and required date through the BOM shortage recovery page, and for loop powered transmitters that also need the regulator and the reference, the power management cross reference page lists the companion parts.
Request Quote — In Stock, 100% New & Original, Full Warranty