AD623ARMZ-REEL7
Product Specifications
AD623ARMZ-REEL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD623ARMZ-REEL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD623ARMZ-REEL7: Gain 1 to 1000 From One Resistor on a 550 uA Budget
The AD623 is a single or dual supply instrumentation amplifier with a rail-to-rail output, running from 2.7 V to 12 V. Gain is set by one external resistor and spans 1 to 1000; with the gain pins open the part is at unity. Maximum quiescent current is 550 microamps, input noise is 35 nV per root hertz at 1 kHz, bandwidth is 800 kHz at unity gain, and settling to 0.01 percent at a gain of 10 takes 20 microseconds. The ARMZ order code is the 8-lead MSOP body.
The bandwidth and settling numbers agree with each other
Divide the 800 kHz unity gain bandwidth by a gain of 10 and the expected bandwidth is 80 kHz. Take the 20 microsecond settling figure instead: 0.01 percent is 9.2 time constants, so the time constant is 2.17 microseconds and the bandwidth is 73.3 kHz. Two different routes to the same answer within 10 percent, which is the check to run when a substitute part quotes one number and not the other.
Noise measured against the source, not in isolation
Integrating 35 nV per root hertz over the full 800 kHz band gives 39.2 microvolts rms at the input; over an 8 kHz band it is 3.92 microvolts. A 1 kohm source contributes about 4 nV per root hertz, so the amplifier is 8.8 times the resistor at that impedance and dominates. At a 100 kohm source the resistor dominates instead, and a lower current noise part, not a lower voltage noise part, is what the application needs.
The published table, as the vendor states it
| Parameter | Value |
|---|---|
| Supply range | 2.7 V to 12 V, single or dual |
| Output swing | rail to rail |
| Input range, single supply | extends 150 mV below ground |
| Quiescent current | 550 microamps maximum |
| Gain | 1 to 1000, one external resistor |
| Gain error | 0.10 percent at G = 1, 0.35 percent at G above 1 |
| Input noise | 35 nV per root hertz at 1 kHz |
| Bandwidth | 800 kHz at G = 1 |
| Settling | 20 microseconds to 0.01 percent at G = 10 |
| Package, this order code | 8-lead MSOP, tape and reel |
What 0.35 percent gain error costs in a loop
Above unity gain the gain error is 3500 ppm. In a 4 to 20 mA current loop that is 56 microamps of span error across the 16 mA span before any calibration, and the external gain resistor adds its own tolerance on top because the gain depends on that resistor directly. A 0.1 percent resistor against a 0.35 percent amplifier error is a sensible pairing; a 1 percent resistor is not, because the resistor becomes the larger term.
Power and headroom
550 microamps at 5 V is 2.75 mW, which is the figure that puts the part in battery instruments. The 150 mV below ground input range on a single supply is what lets a ground referenced thermocouple or bridge sit directly on the input without a negative rail, and the rail-to-rail output recovers the swing that a conventional emitter follower stage would lose.
Selection notes
- One resistor sets gain, so a range change is a resistor change rather than a new board.
- Common mode rejection rises with gain, which is the reason the part is specified at several gains.
- The vendor publishes a common mode range tool for instrumentation amplifiers, useful before a rail is fixed.
- The same family covers dual and quad channel needs for multi-sensor front ends.
Buyer questions
Will it run from a single 3.3 V rail with a ground referenced sensor? Yes. The supply starts at 2.7 V and the input extends 150 mV below ground, so a bridge or a thermocouple biased at ground is inside the range.
Can the gain be changed in the field? Only by changing the gain resistor. That is a one component change, but the resistor tolerance enters the gain error directly, so a field change should come with a two point calibration.
Family page for the category: Analog and mixed-signal ICs. For amplifier families see amplifier cross reference, and for consolidating several analog lines into one shipment see BOM shortage recovery.