Product Specifications

AD5421BREZ — Analog & Mixed-Signal ICs | Superb Automation

AD5421BREZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD5421BREZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD5421BREZ: A 16-Bit 4 mA to 20 mA Transmitter That Runs From the Loop Itself

The AD5421 is a complete loop powered 4 mA to 20 mA digital to analog converter for smart transmitters. It takes its own supply from the loop, regulates that down to a selectable 1.8 V to 12 V rail to power itself and the rest of the transmitter, and holds 16-bit monotonicity with a total unadjusted error of 0.05 percent maximum and an integral nonlinearity of 0.0035 percent of full scale. On chip it carries a 1.22 V and a 2.5 V reference, a fault register with a FAULT pin and a NAMUR compliant alarm current path, and a SPI port that runs at 30 MHz. It comes in a 28-lead TSSOP or a 32-lead LFCSP over minus 40 to plus 105 degrees C, and the loop voltage range is 5.5 V to 52 V.

0.05 percent of 16 mA is 8 uA, and one code is 244 nA

The specified span is 16 mA, so a total unadjusted error of 0.05 percent is 8 uA and the 16-bit resolution is 244 nA per code. In process terms 8 uA is 0.05 percent of the reading, which for a 100 bar pressure transmitter is 50 mbar, and that is the figure a calibration certificate has to quote. The output temperature coefficient of 3 ppm per degree C adds 435 ppm over the 145 degree ambient range, which is 7 uA at 20 mA, so the drift term is the same size as the untrimmed error and cannot be ignored in a certificate that covers temperature.

300 uA of quiescent current out of a 4 mA budget

At the bottom of the range the whole transmitter has 4 mA to work with, and the AD5421 alone draws up to 300 uA, which is 7.5 percent of that budget before the sensor, the microcontroller and the HART modem are counted. That is the number that decides whether the circuit fits: a 4 mA floor leaves 3.7 mA for everything else, and a microcontroller that sleeps at 5 uA and wakes at 2 mA is a different architecture from one that runs continuously. The regulator output range of 1.8 V to 12 V is what lets the same part feed a 3.3 V microcontroller and a 10 V sensor front end.

ParameterValueWhat it decides
Resolution16 bits, monotonicOne code is 244 nA of loop current
Total unadjusted error0.05 percent maximum8 uA, the calibration certificate figure
Integral nonlinearity0.0035 percent of full scale0.56 uA, well inside one code
Output temperature coefficient3 ppm per degree C typical7 uA over the ambient range at 20 mA
Quiescent current300 uA maximum7.5 percent of the 4 mA floor
Regulator output1.8 V to 12 V, selectablePowers the sensor and the host from the loop
References1.22 V and 2.5 V on chip4 ppm per degree C maximum, no external reference
Loop voltage range5.5 V to 52 VSets the minimum compliance and the surge headroom
NAMUR ranges4 to 20, 3.8 to 21, 3.2 to 24 mAPin selected, no register write needed
Alarm currents3.2 mA down, 22.8 or 24 mA upThe two states a host uses to flag a fault
InterfaceSPI to 30 MHz, Schmitt inputsFault register read back on every write cycle
Slew rate controlRegister selectedLimits the step a HART modem sees as noise
Package and range28-lead TSSOP or 32-lead LFCSPMinus 40 to plus 105 degrees C

What the three NAMUR ranges are for

The 4 mA to 20 mA range is the standard, the 3.8 mA to 21 mA range is the NAMUR NE43 signalling band that leaves room for a small over and under range before the alarm thresholds, and the 3.2 mA to 24 mA range is the wide band used where a transmitter must report a fault current at 3.2 mA on the low side and 24 mA on the high side. Selecting the range by pin rather than by register means the range is fixed in hardware, which is what a certified transmitter needs: a misfired SPI write cannot move the output outside the certified band.

HART on top of the loop current

The HART FSK signal is a small ac modulation superimposed on the dc loop current, and it works only if the loop current source has a high output impedance at the signalling frequencies. The AD5421 is specified to work with standard HART modem circuitry without a loss of performance, which in practice means the output stage presents an impedance high enough that the FSK tone is not shunted, and the slew rate control is set so that a step change in the dc level does not look like a burst of FSK to the receiver at the other end. The coupling network and the modem are still external, and the modem's own quiescent current comes out of the same 3.7 mA.

The 5.5 V floor and surge protection

The loop voltage range starts at 5.5 V, which at 4 mA is 22 mW of available power, and that is the operating point for the whole transmitter. A barrier or a long cable run that drops the loop below 5.5 V at the transmitter puts the regulator out of regulation, and the failure shows up as a wrong reading rather than as a dead unit, which is the harder fault to find. On the high side, 52 V is the ceiling, and a surge that takes the loop above it has to be clamped externally; the part protects its own output but not the loop.

Procuring a certified loop transmitter part

This class of part is bought against a certificate, so the order code and the temperature grade are part of the certificate and a substitute with the same function but a different grade is not automatically usable. The converters that can be compared on resolution and interface are listed in ADC DAC cross reference, the route for an instrument bill of materials that spans sensor, converter and passives is described in OEM procurement, and where the exact code is short the options are set out in component lead time solutions.