AD5231BRUZ10
Product Specifications
AD5231BRUZ10
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD5231BRUZ10 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD5231BRUZ10: 1024 Taps That Remember Their Position
The AD5231BRUZ10 is a 1024 position digital potentiometer with nonvolatile memory, in the 10 kohm terminal resistance version. The number that separates it from a volatile digital pot is the on board EEMEM: the wiper setting survives power down, and the part refreshes to that setting at power on without a host command. That removes the microcontroller write that a volatile part needs at every boot, and it removes the failure mode where a supply glitch leaves an amplifier at the wrong gain until the firmware catches up. Resolution is 1024 positions, the resistance options are 10 kohm, 50 kohm and 100 kohm, and the part carries 28 bytes of extra nonvolatile memory for user data such as a serial number or a calibration constant.
Published values
| Parameter | Value |
|---|---|
| Positions | 1024 |
| Terminal resistance | 10 kohm in this version, also 50 kohm and 100 kohm |
| Memory | Nonvolatile, retains the wiper setting |
| Power on behaviour | Refreshes to the stored EEMEM setting |
| Monotonicity | Full monotonic operation |
| User memory | 28 bytes, nonvolatile |
| Write protection | Permanent memory write protection available |
| Readback | Wiper setting readable over the interface |
| Interface | SPI compatible, with increment and decrement commands |
| Body | TSSOP, 16 leads |
Replacing a mechanical trim pot on a sealed board
The usual reason this part appears on a bill of materials is that the mechanical trimmer it replaces cannot be adjusted after the unit is potted, or that the adjustment drifts with vibration. A digital pot solves both, because the setting is a number in memory rather than the position of a wiper on a carbon track, and full monotonic operation means each step in code moves the resistance in the same direction, so a calibration search cannot oscillate. What it does not solve is the tolerance of the end to end resistance, which is much wider than the step size, so a circuit that depended on the absolute value of a trimmed resistor needs a different approach.
Increment and decrement commands and the calibration loop
Predefined increment and decrement instructions let the host step the wiper without sending a full address and data word, which shortens the loop in a calibration routine that hunts for a target. The wiper setting can also be read back, so a routine can verify where it ended instead of assuming the write took effect. Both features matter in a factory calibration fixture, where the time per unit is the cost driver, and they also matter in a field recalibration where the host does not know the stored value at start up.
The 28 bytes of user memory and what to put in them
Twenty eight bytes is enough for a serial number, a calibration date, two or three coefficients and a checksum. Storing the coefficients next to the wiper setting means a replacement board can be programmed from the old one without a host database, which is useful in a service depot. The memory has a finite write endurance, so it is for settings and identity, not for logging. Write protection exists to stop a stray command from overwriting the stored value, and it is permanent per the data sheet, so it should be enabled after the factory calibration step rather than before.
Interface, supply and the digital feedthrough question
The part is SPI compatible and works from a single 2.5 V to 5.5 V supply or a plus and minus 2.5 V dual supply, which covers both logic referenced and bipolar signal paths. In a bipolar amplifier gain loop the digital pot carries the same signal current as the resistor it replaces, so the voltage across the terminals has to stay inside the specified range and the clock feedthrough at each step appears as a small glitch in the gain. Sending the step during a quiet interval in the signal, rather than during a measurement, is the practical way to keep that glitch out of the data. The ADI part second source page lists the digital pot families we hold by resistance and memory type, the pin to pin cross reference page covers the bodies that swap without a board change, and the obsolete part cross reference hub covers parts that have already been dropped from the catalog.