Contact Us

AD421BRZRL

Brand: Analog Devices
Analog Devices AD421BRZRL is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD421BRZRL — Analog & Mixed-Signal ICs | Superb Automation

AD421BRZRL

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD421BRZRL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

AD421BRZRL: 16 bits of resolution, 40 uA of gain error and the 163 codes that go with it

The AD421BRZRL is an Analog Devices loop powered digital to analog converter that drives the 4 mA to 20 mA current loop directly, in a 16-lead SOIC or plastic DIP. It contains a selectable regulator producing 5 V, 3.3 V or 3 V to power itself and the rest of the transmitter, a 2.5 V and a 1.25 V reference, and a sigma delta converter with 16-bit monotonicity and plus or minus 0.01 percent integral nonlinearity. Zero scale offset error is plus or minus 0.1 percent of 4 mA and full scale gain error is plus or minus 0.2 percent of 20 mA. Quiescent current is 750 uA maximum, the serial interface runs to 10 Mbps on three wires, the part is HART compatible without loss of specified performance, and it is specified over -40 C to +85 C. It is on the analog and mixed-signal IC line card.

Sixteen bits of resolution inside a 0.2 percent gain specification

Sixteen milliamps of span across 65536 codes is 244 nA per code. The plus or minus 0.2 percent gain error on 20 mA is 40 uA, which is 163 codes, and the plus or minus 0.1 percent offset error on 4 mA is 4 uA, or 16 codes. The integral nonlinearity of 1.6 uA is 6.6 codes. So the converter resolves 244 nA while its gain uncertainty is 163 times that, which means the part is a 16-bit converter with roughly 11 bits of uncalibrated accuracy. That is not a defect: a smart transmitter is calibrated at two points in production, and after that the resolution is what carries the reading, while the gain term is removed once.

ParameterVendor figureDerived figure
Span and resolution4 mA to 20 mA, 16 bits244.1 nA per code
Integral nonlinearityplus or minus 0.01 percent1.6 uA, 6.6 codes
Offset errorplus or minus 0.1 percent of 4 mA4 uA, 16 codes
Gain errorplus or minus 0.2 percent of 20 mA40 uA, 163 codes
Quiescent current750 uA maximum2.25 mW at 3 V, 3.75 mW at 5 V
Loop budget at 4 mA750 uA taken by the converter3.25 mA left for the sensor and the modem
On chip regulator5 V, 3.3 V or 3 V selectableno separate regulator and reference needed
Serial interface10 Mbps, three wiresa 16-bit update in about 2 us of bus time
External partspassives and one pass transistorthe transistor spans the loop voltage

Three and a quarter milliamps is the whole budget for the rest of the transmitter

A two wire transmitter has 4 mA at its disposal before it signals anything, and the converter itself takes 750 uA of that. What remains, 3.25 mA, has to run the sensor, the amplifier and the HART modem, and the budget does not grow with the loop supply because the current is the signal. At 3 V that is 9.75 mW for the entire analogue front end, which is the number that decides whether a pressure sensor with a bridge excitation of 1 mA can share the loop with a microcontroller and a modem.

Selection notes

  • The integrated regulator and references remove two calibration sources from the bill of materials, at the cost of the regulator's own error sitting inside the loop.
  • HART compatibility without degraded performance is the reason the part stays in production for process transmitters that also carry digital configuration.
  • The pass transistor is external because the loop can sit at 24 V or higher, and the die only spans a few volts of it.
  • A programmable alarm current outside the 4 mA to 20 mA span lets a fault be signalled without a separate line.

Questions buyers ask

Does the part need a separate microcontroller? Yes for a HART transmitter: the serial interface is a three-wire peripheral port, and the protocol stack and the sensor linearisation live in the controller.

Why is the gain error so much larger than the resolution? Because it is a trimming term rather than a noise term. A two point calibration in production removes it, and what remains is the resolution and the nonlinearity.

Converter families are compared on ADC DAC cross reference, and the sourcing options for a running process instrument are on BOM shortage recovery.

Request Quote — In Stock, 100% New & Original, Full Warranty