Contact Us

AD4111BCPZ-RL7

Brand: Analog Devices
Analog Devices AD4111BCPZ-RL7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD4111BCPZ-RL7 — Analog & Mixed-Signal ICs | Superb Automation

AD4111BCPZ-RL7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD4111BCPZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

AD4111BCPZ-RL7: 24-Bit Converter That Takes Plus or Minus 10 V and 0 to 20 mA Directly

The AD4111BCPZ-RL7 is the 40-lead LFCSP body of the AD4111, a single supply, 24-bit sigma-delta converter with an integrated analog front end that accepts plus or minus 10 V on four differential or eight single ended inputs and 0 to 20 mA on four single ended inputs, in production and recommended by the vendor for new builds. The front end is the point: a 1 MOhm or greater input impedance on the voltage channels and 60 Ohm on the current channels means a 10 V industrial signal and a 4 to 20 mA loop can connect without external conditioning, and the part adds open wire detection to catch a disconnected sensor. Where a board compares this against a discrete converter plus amplifier chain, the ADC and DAC cross reference is the page to start from.

What the numbers actually mean

Twenty-four bits at a 20 V span is 1.19 uV per step, but the useful figure is the noise free resolution: 16 noise free bits at 1 kSPS per channel, which is 305 uV of peak to peak noise on that span. The output rate is 1.25 SPS to 31.25 kSPS in total, and the channel scan rate is 6.21 kSPS per channel with 161 us of settling, which is what makes a four channel scan practical at a few kilohertz. Total supply current is 3.9 mA, so the whole front end and converter dissipates under 20 mW.

ParameterFigureWhat it decides in a build
Resolution24 bit, 16 noise free at 1 kSPS305 uV of noise on the 20 V span, ample for a 0.1 percent measurement
Voltage inputsPlus or minus 10 V, four differential or eight single ended1 MOhm or more, so a 10 V sensor connects without a buffer
Current inputs0 to 20 mA, four single ended, 60 OhmA loop drops 1.2 V at 20 mA and needs no shunt of your own
AccuracyPlus or minus 0.06 percent at 25 C on voltage, 0.08 percent on current12 mV on the 20 V span, 16 uA on the loop
Reference2.5 V on chip, plus or minus 0.12 percent, 5 ppm per degree C typicalRemoves an external reference from the bill
Rejection85 dB at 50 and 60 Hz at 20 SPSMains pickup rejected in the converter rather than in a filter
Supply3.0 V to 5.5 V analog, 2 V to 5.5 V digital, 3.9 mA total19.5 mW, so a loop powered transmitter is possible

Where it can surprise a build

The plus or minus 10 V inputs come from a single supply, which is a genuine convenience and does not make the part a substitute for an isolated front end. The absolute maximum on the input pins is plus or minus 50 V, which is protection, not a working range, and a 24 V industrial fault can still destroy the part if the current is not limited.

The current channel is 60 Ohm, so 20 mA drops 1.2 V and dissipates 24 mW in the part. That is fine for one channel and adds up across four, which is part of the 3.9 mA supply budget and the reason a loop powered transmitter has to account for the drop in its compliance calculation.

The 16 noise free bits headline belongs to 1 kSPS per channel. At the maximum 31.25 kSPS in total, divided across four channels, the noise free resolution falls, and a build that needs 20 bits at speed is asking for a different family. The vendor's own noise tables across output rates are the number to use, not the headline.

Applications and how it fits a process transmitter

Programmable logic controller analog input cards, process transmitters, temperature and pressure measurement, and any rack that mixes a 10 V signal with a current loop. The open wire detection and the diagnostics exist because a broken sensor wire in a plant reads as a valid low signal, which is the failure mode that costs a day of production. For builds that must keep running while a specific order code is short, component lead time solutions covers the qualification of an alternative front end.

The rest of the precision converter range, including the lower channel count members, is on the analog and mixed-signal IC page.

Questions buyers ask about this order code

Is the BCPZ-RL7 the 40-lead LFCSP? Yes, and the reel is the only difference from the tube option. The analog front end configuration is fixed by the die and selected in registers, so the order code does not carry a channel option.

Can both the voltage and the current inputs be used at once? They are separate input groups and the channel sequencer selects between them, so a scan can cover both. The settling time per channel applies to each hop, so mixing the two types costs the same 161 us per channel.

Does the on-chip reference need an external capacitor? It needs its decoupling and it needs the specified settling before a conversion is valid. A board that starts converting immediately after power up will read the reference's own settling as signal drift.

Request Quote — In Stock, 100% New & Original, Full Warranty