HX231490CR5
Product Specifications
HX231490CR5
Hisiwell — Amplifiers & Comparators
Product Overview
The HX231490CR5 from Hisiwell is a precision amplifier / comparator delivering high gain, wide bandwidth, and low distortion for signal conditioning. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High gain-bandwidth product for wideband signal amplification
- Low input offset voltage and drift for precision DC applications
- EMI-hardened design for robust operation in noisy environments
- Rail-to-rail input/output for maximum dynamic range
- Low quiescent current for power-sensitive designs
- Unity-gain stable with capacitive load drive capability
Key Specifications
| Channels | — |
| GBWP | MHz |
| Slew Rate | V/µs |
| Vos | µV |
| Iq per Channel | µA |
| Input Type | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
Applications
HX231490CR5: the carrier version, and what changes when the die arrives mounted
The HX231490CR5 covers 8 to 11 GHz with 23 dB of gain, 37 dBm at the 1 dB compression point and 35 percent power added efficiency from 8 V, supplied as a die on a carrier. It shares its frequency, gain and output with the QFN 6 x 6 part in the same table and differs in two columns: the package and five points of efficiency.
What the vendor publishes
| Parameter | Value |
|---|---|
| Frequency range | 8 to 11 GHz |
| Small signal gain | 23 dB |
| Output P-1dB | 37 dBm |
| PAE | 35 percent |
| IMD3 | not published |
| Supply | 8 V, 1.6 A in the supply column |
| Package | carrier |
14.3 W of DC for 5.01 W of RF
37 dBm is 5.01 W. At 35 percent efficiency the DC input is 14.32 W, which at 8 V is 1.79 A, and 9.3 W leaves as heat. The supply column reads 1.6 A, 12.8 W, which would be 39.2 percent, above the published figure, so the 1.6 A is best read as a quiescent or small signal current. The drain path, the choke and the bias feed should be sized on 1.79 A.
What a carrier does for the assembly
A bare die needs wire bonds to the board, a die attach process and a bond loop length that has to be repeated exactly from unit to unit. A carrier arrives with the die already attached and the RF and DC connections brought out to pads that can be soldered, so the assembly house handles a component rather than an unpackaged die. On an 8 to 11 GHz part that matters twice: the bond wire length is fixed by the vendor rather than by the operator, and the thermal interface is a solder joint under a metal tab instead of an epoxy dot. The five points of efficiency between this row and the QFN row are consistent with that larger thermal interface.
Where the carrier still needs care
The carrier is not a package with a lid, so the die surface stays exposed. Cleaning, handling and any conformal coat have to be checked against the die, and the part should not be placed where a foreign object can land on it. The carrier also has its own footprint, usually larger than the QFN, which can force a change in the board outline if the part is being substituted late in a programme. Both points are worth settling before the footprint is released, not after.
Two questions buyers ask
Is the 35 percent figure for the same drive level as the 30 percent QFN figure? The table does not say, and the two rows agree on every other parameter. The safe reading is that the carrier figure reflects the better thermal path at the same electrical operating point.
Can it be supplied on tape and reel? Carriers are usually supplied in waffle packs or gel packs, not tape and reel. If the assembly line needs reeled parts, plan for a tray-fed placement step or ask the vendor for the packing option before the order.
SUPERB supplies the HX231490CR5 on the vendor row above and quotes it with its QFN sibling so the thermal and assembly trade can be priced together. For a part being replaced in an existing 8 to 11 GHz lineup, amplifier cross reference lists the checks. For allocation on the bias and matching parts, see BOM shortage recovery. Stock is quoted from the amplifiers and comparators index.
HX231490CR5: measuring 5 W at X band without measuring the bench
Five watts at 8 to 11 GHz is the level where a bench setup starts to contribute more error than the part contributes variation. A power sensor that tops out at plus 20 dBm needs 17 dB of attenuation in front of it, the attenuator has to survive 5 W, the cable has to be characterised rather than assumed, and the connector repeatability is a fraction of a dB that becomes a fraction of a watt. This block is about the measurement, because the RF figures on the row are only as good as the fixture that produced them.
The attenuator is the instrument
37 dBm is 5.01 W. A 30 dB pad brings that to 7 dBm, which is 5.01 mW and inside the range of every sensor, and the pad itself has to dissipate 5.007 W continuously. A 10 W pad is the minimum rating and 20 W is the sensible one, because a pad run at half its rating drifts and its attenuation drifts with it. A 20 dB pad instead leaves 17 dBm at the sensor, which is 50 mW and at the top of many sensor ranges; it also has to dissipate 4.96 W, so the rating argument is the same and the sensor headroom is worse.
| Pad | At the sensor | Heat in the pad | Note |
|---|---|---|---|
| 20 dB | 17 dBm, 50 mW | 4.96 W | top of many sensor ranges |
| 30 dB | 7 dBm, 5.01 mW | 5.01 W | comfortable for any sensor |
| 40 dB | minus 3 dBm, 0.5 mW | 5.01 W | sensor noise floor enters |
Cable loss has to be measured, not assumed
One decibel of unaccounted loss on a 5.01 W reading is 1.3 W, 26 percent of the measurement. At 10 GHz a metre of a thin flexible cable can easily lose a decibel, and the loss changes when the cable is bent, so a setup that was corrected once and then re routed is uncorrected again. The working method is to measure the cable and pad together with a source of known output, or with a second sensor at the far end, and to keep that correction with the fixture rather than with the operator.
Pulse and continuous measurements are not interchangeable
A diode detector reads the envelope and is calibrated for continuous wave; on a pulsed signal it reads the peak, not the average, and a thermal sensor reads the average and responds too slowly for short pulses. On a radar pulse train the average power is duty times peak, and reporting one as the other is a common source of a 10 dB disagreement between a vendor and a customer. Ask which the number is.
Two questions buyers ask
Why does the carrier row show five points more efficiency than the QFN row? A carrier presents the die on a metal tab with a larger interface than an exposed pad, so the die runs cooler at the same dissipation and the bias point holds. It is a thermal effect that shows up in an electrical column.
Is the 1.6 A in the supply column the current at compression? No. 5.01 W at 35 percent needs 14.32 W of DC, which at 8 V is 1.79 A. The 1.6 A is the quiescent or small signal value, and the feed has to be built for 1.79 A. Parts in this band and their measurement data are on RF component sourcing, the defence grade route is on defense grade components, and the comparison route between amplifier families is on amplifier cross reference.
Request Quote — In Stock, 100% New & Original, Full Warranty