Contact Us

DIN and Circular Connectors for Panel Wiring

A rack card and a panel box need two different connectors, and both have to survive a harness that was made somewhere else.\nThe DIN 41612 parts here run 32, 64 and 96 ways at 2 A per contact on a 2.54 mm pitch, in rows a, b and c, straight or right angle.\nThe M12 parts are 4 position A and D coded panel feed throughs, rated 4 A at 250 V and sealed to IP67 to IEC 61076-2-101.\nEvery row states the termination length and the coding, because those two decide whether the mating half fits.
quote now

Product Specifications

Product Overview

Two connector families cover most of the panel and rack wiring on an industrial product. The DIN 41612 family is the board to backplane connector: a long rectangular body with two or three rows of contacts on a 2.54 mm pitch, keyed so that a card cannot be inserted the wrong way, and rated at 2 A per contact for the signal versions. The M12 family is the panel connector: a round threaded body with 4, 5 or 8 contacts, sealed to IP67, and used for sensors, actuators and Ethernet links on the outside of an enclosure.

The DIN parts on this page are Harting type C and type Q connectors. The type C body carries 32, 64 or 96 contacts in rows a, b and c, with straight or right angle solder pins, and the contact plating is performance level 2 as defined in DIN 41612 part 5. The 64 way version in rows a and c is the common part for a 64 line backplane, and the 96 way version uses all three rows. The insulator is glass filled thermoplastic with a UL94 V-0 rating, and the operating range is -55 to +125 C.

The M12 parts are Phoenix Contact panel feed throughs. The 4 position A coded part is the standard sensor and actuator connection, rated 4 A at 250 V, with a contact resistance of 3 mOhm or less and an insulation resistance of 100 MOhm or more. The D coded part uses the same 4 contacts but a different keyway, so an Ethernet cable cannot be plugged into an A coded socket. Both are sealed to IP67, which is the rating that matters when the connector is on the outside of a box that is washed down.

The termination is where a DIN connector order goes wrong. A straight solder pin and a right angle solder pin of the same contact count are different parts with different board footprints, and a right angle part with a 3 mm termination length will not reach a 4.5 mm plated through hole. The termination length and the angle are stated per part in the table below, and they have to be checked against the board thickness before the order.

The second point is the coding. A DIN 41612 connector uses loss of contacts for keying, so a 64 way plug can be made to fit a 96 way socket only where the coding allows it. An M12 connector uses the keyway of the shell. In both cases the mating half is part of the order, and a connector quoted without its mating half is only half a connection. We quote the pair and state the coding on both.

Key Specifications

ParameterValueApplies to
DIN contact count32, 64 or 96 contactsHarting type C
DIN contact rowsa and c, a and b, or a, b and cPer part number
DIN pitch2.54 mmHarting type C
DIN current rating2 A per contactHarting type C
DIN terminationStraight or right angle solder pins, 2.9 to 4.5 mmPer part number
DIN insulatorGlass filled thermoplastic, UL94 V-0Harting type C
DIN operating temperature-55 to +125 CHarting type C
DIN platingPerformance level 2, noble metal over nickelHarting type C
M12 standardIEC 61076-2-101Phoenix Contact M12
M12 positions4, A coded or D codedPer part number
M12 current rating4 A at 40 CPhoenix Contact M12
M12 voltage rating250 VPhoenix Contact M12
M12 contact resistance3 mOhm or lessPhoenix Contact M12
M12 insulation resistance100 mOhm or morePhoenix Contact M12
M12 sealingIP67Phoenix Contact M12
M12 operating temperature-25 to +85 CSACC-E-M12FS-4CON-PG9/1,0

Included Models and Order Codes

The rows below are the board and panel parts we quote most often. The DIN rows give the rows and the termination because those decide the footprint; the M12 rows give the coding and the cable length because those decide the harness. A dash means the maker does not publish that figure.

Part NumberContactsRows or CodingTerminationRatingMountNotes
09 03 164 692164Rows a and cRight angle solder pins2 A per contactBoardFemale, type C
09 02 164 692164Rows a and bRight angle solder pins2 A per contactBoardFemale, type C, different keying
09 03 132 692132Rows a and cRight angle solder pins2 A per contactBoardFemale, half the length of a 64 way
09 03 296 682596Rows a, b and cStraight solder pins, 4.5 mm2 A per contactBoardFemale, wave solder
09 03 664 692196Rows a, b and cRight angle solder pins2 A per contactBoardMale header, type C
15518754A coded0.5 m wires4 A, 250 VPanel, rear mountM12 feed through, IP67
15032764A coded1 m TPE wires, 4 x 0.25 mm24 A, 250 VPanel, PG9 threadM12 socket, IP67, -25 to +85 C
14243264D codedSolder, M16 x 1.5 thread4 A, 250 VPanel, bipolar mountM12 data feed through, IP67

Key Features

Rows and termination stated – Every DIN row gives the rows and the termination length, so the footprint and the board thickness are checked before the order.

Coding on both halves – The DIN keying and the M12 keyway are stated, and the mating half is quoted with the connector rather than left to chance.

Two amp signal rating – The 2 A per contact rating of the type C body covers the signal and low power lines on a rack card without a separate power connector.

IP67 on the panel parts – The M12 feed throughs are sealed to IP67, which is what a panel connector needs on a box that is washed or used outdoors.

A and D coding in one family – The same 4 position body is offered in A coding for power and signals and D coding for Ethernet, so a panel can carry both without a second family.

Wide temperature range – The DIN parts are rated -55 to +125 C, which covers a rack that runs warm and a panel that is installed outdoors.

Applications

These connectors are used where a board has to leave its enclosure, or where a card has to plug into a backplane.

Rack and backplane cards – A 64 or 96 way DIN connector carries the signals and the low power rails from a card to the backplane, keyed so the card cannot go in the wrong slot.

Sensor and actuator panels – A 4 position A coded M12 feed through brings a sensor cable into a sealed box, with the thread doing the sealing and the strain relief.

Ethernet on the panel – A D coded M12 part carries a 100 Mbit link through a panel without an RJ45, which is the usual answer on a machine that is washed down.

The connector is fitted on the SUPERB PCB or on the panel of the same unit, and the SUPERB PCBA route checks the pin numbering against the harness drawing before the cable is made.

Sourcing and Cross-Reference

A DIN connector is ordered by contact count, but it is approved by rows and termination. A 64 way part in rows a and c is not the same footprint as a 64 way part in rows a and b, and a right angle part will not fit a board laid out for a straight one. We ask for the old part number and the board drawing, and we match on the rows, the angle and the termination length before anything else.

The second point is the plating level. DIN 41612 defines performance levels by the number of mating cycles, and a level 2 part is the usual choice for a card that is inserted a few hundred times. A level 1 part costs more and is used where the card is inserted daily. The two are visually similar, so the level is quoted explicitly rather than left to the part number alone.

M12 parts are simpler, because the standard fixes the thread and the sealing. The trap is the coding and the wire length. A D coded socket will not take an A coded cable, and a 0.5 m fly lead is not enough for a panel that is 60 mm thick. We ask for the panel thickness and the cable length, and we quote the part with the right lead rather than a part plus an extension.

SUPERB Assembly keeps the connectors in their trays until the wave or the press fit step, because a bent pin on a 96 way part cannot be straightened without losing the plating.

Q: Can you supply the DIN connector and its mating half as a coded pair, and confirm the termination length against our board thickness?

A: Send the contact count, the rows you need, the termination and whether the connector is on the board or on the panel. The SUPERB Tech desk quotes the mating pair so the two halves arrive with the same coding.

Why Buy DIN and M12 Connectors Through SUPERB

  1. Rows and angle matched: The DIN quote is built from the rows, the termination angle and the length, which is where a connector usually fails to fit.
  2. Mating half included: The plug or socket is quoted with the connector, with the coding stated on both, so the pair arrives matched.
  3. Plating level stated: The DIN performance level is given, so a part for a card that is inserted daily is not confused with a standard part.
  4. Sealing rated: The M12 parts carry their IP67 rating and their temperature range, which is what a panel connector has to hold in service.
  5. Harness checked: The pin numbering is checked against the harness drawing before the cable is made, so the first article is not a rework.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Screw Terminal Blocks and Pluggable Connectors for Field Wiring, Wire to Board Crimp Housings and Headers for Harness Builds, RF Coaxial Connectors and Adapters for Test and Antenna Runs, Board to Board and FPC Connectors for Compact Assemblies, Connector Cross Reference.