Current Transformers and AC Current Sensing for Energy Metering
Product Specifications
Product Overview
A current transformer measures an alternating current without opening the circuit and without adding a shunt in the load path. The primary is the wire that passes through the core, or a single turn inside a PCB part, and the secondary winding delivers a current that is the primary divided by the turns ratio. Because the secondary is loaded with a small resistor, the output that reaches the meter is a voltage, and the isolation between the primary and the measurement circuit is set by the winding insulation rather than by the board.
The split core clamp is the form that suits a retrofit. The jaw opens, the conductor is laid inside, and the clamp closes around it, so a sub meter can be added to an existing distribution board without cutting a cable. The family covers 5 A to 100 A, and the output is either a current, typically 50 mA at 100 A, or a voltage of 1 V or 0.333 V developed across a burden resistor that sits inside the housing. The current output version leaves the burden choice to the user, which is what a metering chip with a fixed input range wants, and the voltage output version is what a microcontroller ADC wants.
The PCB part is the form that suits a product. A 5 A or 20 A transformer with a 5 mm bore sits on the board, the load current passes through a trace that goes through the bore, and the secondary is terminated by a resistor that the engineer picks. Accuracy class, phase error and linearity are quoted at a stated burden, so the same part can be a class 0.2 meter transformer at 50 ohm and a coarser device at 200 ohm. Reading phase error matters as soon as the load has a poor power factor: at a power factor of 0.5 a phase error of 15 minutes turns into a few tenths of a percent of error in the watt reading, which is enough to fail a class 1 meter.
A voltage transformer is the same construction used the other way. The ZMPT101B takes 2 mA through a series resistor from the mains, and returns 2 mA into a sampling resistor, so the mains waveform is reproduced at a low level with 4000 V of isolation and a phase error of 20 minutes. That is how a single phase energy meter samples voltage and current with two similar parts and one ADC, and it keeps the divider resistors and the isolation barrier off the low voltage board.
The table below covers the three groups we quote most often: split core clamps for retrofit sub metering, PCB current transformers for products that build the meter into the board, and the current type voltage transformer for the voltage channel. Primary current, output, turns ratio, burden, accuracy and opening size come from the maker data sheet for each order code.
Key Specifications
| Parameter | Split core clamp, SCT-013 | PCB current transformer, ZMCT and AC | Current type voltage transformer, ZMPT101B |
|---|---|---|---|
| Rated primary current | 5 A to 100 A | 5 A to 25 A | 2 mA through a series resistor |
| Rated output | 50 mA, 0.333 V or 1 V by code | 2.5 mA or 5 mA at 5 A, 10 mA at 10 A, 20 mA at 20 A | 2 mA |
| Turns ratio | 100 A to 50 mA on the current output codes | 1000:1 or 2000:1 | 1000:1000 |
| Burden | 10 ohm on the SCT-013-000, built in on the voltage output codes | 50 ohm or 100 ohm, stated with the accuracy class | 100 ohm sampling resistor |
| Accuracy | plus or minus 1 percent of reading | class 0.1 or class 0.2 | linearity 0.2 percent, error -0.3 to +0.2 percent |
| Phase error | Not quoted per code, keep the burden low | 15 minutes on ZMCT103C at 5 A and 50 ohm | 20 minutes at 2 mA and 100 ohm |
| Operating frequency | 50 Hz to 1 kHz | 50 Hz to 60 Hz | 50 Hz to 60 Hz |
| Isolation | 6 kV AC for one minute on the housing | 4000 V on the ZMCT103C | 4000 V |
| Opening | 13 mm by 13 mm jaw | 5 mm bore | Not applicable, wired primary |
| Operating temperature | -25 C to +60 C | -40 C to +85 C on ZMCT parts | -40 C to +60 C |
| Mount | Clamp on cable, 1 m lead with 3.5 mm plug | PCB through hole pins | PCB through hole pins |
Included Models and Order Codes
The table lists the order codes we quote most often for sub metering, motor protection and energy measurement. Primary current, output, turns ratio, burden and accuracy come from the maker data sheet for that code. The last two digits of a split core code carry the rated primary current, so the SCT-013-030 and the SCT-013-050 are the same housing with a different winding and are never interchanged on a quotation.
| Part Number | Primary | Output | Turns Ratio | Burden | Accuracy | Mount |
|---|---|---|---|---|---|---|
| SCT-013-000 | 100 A AC | 50 mA | 100 A to 50 mA | 10 ohm external | plus or minus 1 percent | Split core, 13 mm opening |
| SCT-013-000V | 100 A AC | 1 V | 100 A to 1 V | 18.6 ohm built in | plus or minus 1 percent | Split core, 13 mm opening |
| SCT-013-030 | 30 A AC | 1 V | 30 A to 1 V | Built in | plus or minus 1 percent | Split core, 13 mm opening |
| SCT-013-050 | 50 A AC | 1 V | 50 A to 1 V | Built in | plus or minus 1 percent | Split core, 13 mm opening |
| SCT-013-060 | 60 A AC | 1 V | 60 A to 1 V | Built in | plus or minus 1 percent | Split core, 13 mm opening |
| ZMCT103C | 5 A AC | 5 mA | 1000:1 | 50 ohm | Class 0.2, 15 minutes | PCB, 5 mm bore |
| ZMCT102 | 5 A AC | 2.5 mA | 2000:1 | 100 ohm | Class 0.1 | PCB, 5 mm bore |
| ZMPT101B | 2 mA at 1000 V max | 2 mA | 1000:1000 | 100 ohm | 0.2 percent linearity | PCB, voltage channel |
| AC1010 | 10 A AC | 1.0 V into 100 ohm | 1000:1 | 100 ohm | Ratio correction 1.010 | PCB through hole |
| AC1015 | 15 A AC | 1.5 V into 100 ohm | 1000:1 | 100 ohm | Ratio correction 1.010 | PCB through hole |
| AC1020 | 20 A AC | 2.0 V into 100 ohm | 1000:1 | 100 ohm | Ratio correction 1.010 | PCB through hole |
| AC1025 | 25 A AC | 2.5 V into 100 ohm | 1000:1 | 100 ohm | Ratio correction 1.020 | PCB through hole |
Key Features
No shunt in the load path – the primary conductor passes through the core, so there is no series resistance to heat, no millivolt drop at 30 A and no need to break the cable to insert the sensor.
Burden decides the output and the accuracy – a 100 A to 50 mA part with a 10 ohm burden gives 0.5 V at rated current, and the same part into 33 ohm gives 1.65 V but a wider phase error, which is why the burden is quoted with the accuracy class rather than after it.
Phase error matters at poor power factor – 15 minutes of phase error is 0.16 percent of error in the watt reading at unity power factor but about 0.3 percent at a power factor of 0.5, so a class 1 meter needs the phase figure before the turns ratio.
Split core for retrofit work – the jaw opens to 13 mm and closes on the conductor, and the housing is rated for 1000 open and close cycles, which is what a sub meter installed in an existing panel needs.
Voltage channel from the same family – the ZMPT101B takes a 2 mA current from the mains through a series resistor and returns 2 mA, so the voltage channel has the same shape as the current channel and one ADC front end serves both.
Built in burden on the voltage output codes – the codes with a V suffix carry the burden resistor and a transient suppressor inside the housing, so a 3.5 mm plug feeds a microcontroller ADC without an external resistor network.
Applications
These parts are quoted for products that measure AC current or AC power, typically where:
Sub metering and energy monitoring – a split core clamp on each outgoing way of a distribution board feeds a multi channel meter, and the 1 V output codes let one ADC sample eight circuits without a separate burden per channel.
Motor overload and pump protection – a PCB transformer on the drive board tracks the phase current, and the class 0.2 part gives an overload trip that holds its threshold over temperature instead of drifting with a shunt amplifier.
EV charger and inverter AC side – the clamp or the PCB part measures the current drawn from the grid, and the 4000 V isolation keeps the measurement circuit on the safe side of the barrier while the conductor stays at mains potential.
The clamp or the PCB transformer is fitted to the metering board, so it is quoted together with the SUPERB PCB and the SUPERB PCBA build for that board.
Sourcing and Cross-Reference
Selection starts from the burden the measuring circuit can accept. A meter chip with a 50 mV input wants the current output clamp and a burden chosen to land at 50 mV at rated current, while a 3.3 V ADC with a bias network wants the 1 V output code and no external parts. Reading the output type as the first field, and the rated current as the second, prevents the common mistake of buying a 100 A to 50 mA clamp for a board that expects 1 V.
The second check is the conductor and the panel. The clamp opening has to take the insulation of the cable, not just the copper, and the jaw has to close fully or the core gap adds a large ratio error. A PCB part needs the load trace to pass through the bore with the specified clearance, and the secondary side has to keep its creepage distance from the primary trace, because the isolation figure of the part is only as good as the board under it.
Where a code is hard to find, the substitution is checked on rated current, output type, turns ratio, burden, accuracy class and opening at once, since two clamps that look the same often differ in the built in burden. The verification route is on our verify original components page, and the lead time options are on component lead time solutions.
For volume builds, SUPERB Assembly support covers the secondary lead dress, the creepage slot under the transformer and the calibration step that sets the ratio correction.
Q: Can you supply SCT-013-030 clamps with the 3.5 mm plug, and confirm the burden and bias network for a 3.3 V ADC?
A: Yes. Send the rated current, the output type the ADC expects and the accuracy class, and the SUPERB Tech team will confirm the code, the burden and the isolation from the maker data sheet before quoting.
Why Buyers Source Current Transformers Through SUPERB
- Output type confirmed before the code: the quotation states whether the part gives 50 mA, 0.333 V or 1 V, because that single field decides the whole front end and is the most common source of a wrong order.
- Burden and accuracy quoted together: the class is only valid at a stated burden, so both figures are given on the same line instead of leaving the accuracy to be assumed.
- Split core and PCB forms in one place: a retrofit clamp and a board mounted transformer can be quoted on the same order, which keeps one ratio convention across a product family.
- Counterfeit checks on split core parts: the SCT-013 family is widely copied, so the marking, the lead length and the plug are checked against the maker sheet before a lot is offered.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Passive components, Current sense shunt resistors, Hall effect current sensors, Ethernet magnetics and PoE transformers, Common mode chokes and power inductors, Verifying original components, Component lead time solutions.