TPS54060ADGQ
Product Specifications
TPS54060ADGQ
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS54060ADGQ from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS54060A 60 V 0.5 A step down converter with Eco-mode for wide input rails
The TPS54060ADGQ is a 60 V, 0.5 A step down regulator with the high side switch inside the package, in the 10 pin VSSOP body with an exposed pad. It takes an input from 3.5 V to 60 V, which covers a 48 V telecom rail, a 24 V industrial bus and a 12 V automotive accessory line with the same part number and the same external components apart from the divider. The switch is a 200 milliohm n channel MOSFET, and the boot diode is integrated, so the only parts outside the regulator are the inductor, the output capacitor, the compensation network and the boot capacitor.
The A suffix matters. It has a tighter enable window than the earlier TPS54060, 1.11 V to 1.36 V instead of 0.9 V to 1.55 V, which turns the enable pin into a usable undervoltage lockout instead of a rough on off input. On a 24 V bus that sags during a motor start, that difference is what keeps the rail from resetting the load at 14 V instead of 18 V.
Key parameters taken from the SLVS919C document
| Input range | 3.5 V to 60 V operating, 65 V absolute maximum on VIN, with an internal UVLO at 2.5 V that has no hysteresis |
| Output current | 0.5 A continuous, with the high side switch rated at 0.6 A minimum and 0.94 A typical current limit at 12 V in and 25 degrees |
| Switch resistance | 300 milliohm at 3.5 V in, 200 milliohm typical and 410 milliohm maximum at 12 V in |
| Switching frequency | 100 kHz to 2.5 MHz set by a resistor from RT/CLK to ground, or locked to an external clock through the internal phase lock loop |
| Reference | 0.8 V, 0.792 V to 0.808 V at 25 degrees, 0.784 V to 0.816 V over minus 40 to plus 150 degrees |
| Quiescent current | 116 microamp typical and 136 microamp maximum while not switching at 12 V in, 1.3 microamp typical and 4 microamp maximum in shutdown |
| Enable pin | 1.11 V to 1.36 V window on the A suffix, 3.8 microamp of hysteresis current for a divider, and a floating pin means enabled |
| Soft start | 2 microamp into the SS/TR capacitor, with the SS/TR to VSENSE crossover at 98 per cent of nominal |
| Thermal | Shutdown at 182 degrees, 62.5 degrees per watt in the DGQ body on a standard board and 40 degrees per watt in the DRC body |
| ESD | 2000 V human body model and 500 V charged device model |
What Eco-mode does to a light load
At light load the part stops switching when the peak switch current in a cycle falls below the pulse skip threshold, and the COMP pin is clamped at 500 mV while the high side switch stays off. The output then decays on the load until the next burst. The vendor's efficiency curve for 12 V in and 3.3 V out at 500 kHz shows the benefit plainly: the curve stays high down to a few milliamps instead of falling away as it would with forced continuous conduction. For a board that idles most of the time, a sensor node or a standby rail, this is worth more than a marginally better full load figure.
The cost is ripple at light load, since the output is allowed to drift between bursts, and a small amount of audible noise if the burst rate lands in the audio band. Increasing the output capacitance or reducing the inductor value moves the burst frequency up and out of hearing. A rail that feeds an ADC reference should not run in this mode at all, and the vendor shows the alternative of synchronising the part to an external clock, which keeps the switching continuous.
Setting the frequency and the lockout from two resistors
The RT/CLK pin sets the frequency with a resistor to ground. The vendor gives the transfer as RT equal to 206033 divided by the switching frequency in kHz to the power 1.0888, which is close to linear over the 100 kHz to 2.5 MHz range but not exactly, so the resistor should be read from the curve rather than from a linear estimate at the top of the range. Above a threshold the pin becomes a clock input and the internal amplifier is disabled, which lets the rail follow a system clock and keeps the switching harmonics away from a measured band.
The enable pin has an internal pull up current source, so two resistors from VIN to EN and EN to ground set a lockout with hysteresis, using the 2.9 microamp hysteresis current. With the pin floating the part runs, which is convenient on a bench and dangerous on a product: a board with the divider left unpopulated will start at 3.5 V instead of at the intended 18 V.
Compensation and the parts that actually change the loop
This is a current mode part, so the compensation is a type two network on COMP: a resistor and capacitor to ground, usually with a second capacitor in parallel to roll off the high frequency gain. The vendor's application table gives values for a set of standard outputs, and the one value that matters most is the output capacitor, because the crossover is set by the output pole. A rail built with a 47 microfarad electrolytic will need a different compensation network from the same rail built with two 22 microfarad ceramics, even though the regulator, inductor and frequency are unchanged.
Where the part fits and how to source it
Typical sockets are 24 V and 48 V industrial rails, a 12 V to 3.3 V housekeeping supply in a telecom card, and a bias rail in a motor drive where the 60 V rating covers the back EMF. The 0.5 A rating is what limits the application: it is a bias supply, not a main rail, and the 200 milliohm switch means the dissipation at half an amp is already 50 milliwatts before switching loss.
The A suffix and the plain suffix are not interchangeable in a circuit that relies on the enable window, so a quote should name the exact suffix. The VSSOP and VSON bodies share the die but not the thermal figure, and a board that was qualified with the VSON will run hotter with the VSSOP at the same load. Our desk quotes the suffix, the body and the reel size together, and if the exact suffix is short we show the difference in the enable window before proposing a substitute. See power management cross reference and component lead time solutions.
Frequently asked questions
Can the part run from a 48 V bus directly. Yes, 60 V is the recommended maximum and 65 V the absolute maximum, so a 48 V rail with a 20 per cent transient reaches 58 V and stays inside the window, while a 48 V rail with a load dump on it does not.
What happens below 3.5 V. The internal UVLO holds the part off at 2.5 V, so the useful floor is the recommended minimum rather than the UVLO, and below 3.5 V the switch resistance and the current limit are no longer specified. For a rail that has to work down to 3 V, the 3.5 V minimum is the number to work against. More on the sourcing side is on one stop BOM sourcing.