AMC1400DWLR
Product Specifications
AMC1400DWLR
Texas Instruments — Power Management & Signal Chain
Product Overview
The AMC1400DWLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AMC1400DWLR plus or minus 250 mV input isolated amplifier in the stretched SOIC body
The AMC1400DWLR is a reinforced isolated amplifier for shunt based current measurement, with a plus or minus 250 mV input range and a fixed gain of 8.2. It ships in a stretched SOIC body with 15.7 mm of creepage, which is the reason it exists next to smaller isolated amplifiers: the package, not the silicon, is what carries the 10600 V peak rating and the 7500 V RMS one minute rating. The input is built for a low impedance source, so a shunt resistor connects directly across the input pins.
The signal chain this part belongs to is simple to describe and hard to get right. A shunt in the return path of a half bridge develops a few tens of millivolts, with a common mode that swings at the switching frequency of the bridge and a dv/dt that can reach tens of kilovolts per microsecond. The amplifier has to measure the small differential signal while rejecting that common mode, and then hand a scaled copy to a converter on the control side with enough accuracy that the current loop closes on a real number. Every specification below is a piece of that job.
Key parameters taken from the AMC1400DWLR document
| Input range | Plus or minus 250 mV linear, fixed gain 8.2 V per V, giving plus or minus 2.05 V differential at the output |
| Offset error | Plus or minus 0.2 mV maximum, which is 0.08 percent of the input range |
| Offset drift | Plus or minus 0.9 microvolt per C maximum over minus 40 to plus 125 C |
| Gain error | Plus or minus 0.3 percent maximum, with plus or minus 30 ppm per C of gain drift |
| Nonlinearity | 0.03 percent maximum, so the transfer curve stays straight across the full input window |
| Common mode transient immunity | 100 kV per microsecond minimum, the figure that decides whether a fast bridge can be measured |
| Isolation | 10600 V peak reinforced per VDE 0884-17, 7500 V RMS for one minute per UL1577, working voltage 2000 V RMS |
| Creepage | 15.7 mm in the stretched SOIC body, which is what a high pollution degree file usually asks for |
| Supplies | 3.3 V or 5 V on both the high side and the low side, with missing high side supply detection |
| Emissions | Meets CISPR-11 and CISPR-32 limits, which matters when the amplifier sits beside a radio |
| Temperature | Minus 40 to plus 125 C, fully specified over the range |
| Body | SOIC DWL eight pins, 15 mm stretched body |
| Order code facts | AMC1400DWLR, SOIC DWL eight pins, 500 pieces on a large reel, moisture level 3 with a 168 hour floor life, marking 1400 |
| Applications | Motor drives, frequency inverters, solar and wind inverters, rail traction converters and DC to DC converters |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The 250 mV input range sets the shunt value, and the shunt value sets the loss. A 250 mV full scale across a 1 milliohm shunt gives 250 A of range and 62.5 W of loss at full scale, which is why most drives use a smaller shunt and give up range. A 0.5 milliohm shunt halves the loss and halves the range, so the same amplifier serves a 125 A drive. The trade is decided by the loss the thermal file allows at continuous current, not by the amplifier.
The 8.2 gain gives plus or minus 2.05 V at the output, which fits a converter with a plus or minus 2.5 V window and leaves half a volt of headroom on each side. That headroom is what keeps an overshoot from clipping the measurement, and a clipped measurement during a fault is worse than a coarse one, because the current loop loses the information it needs at exactly the moment it matters. A converter with a smaller window forces either a smaller shunt or a divider after the amplifier, and both are worse than choosing the right converter at the start.
The stretched body is the reason this part shows up in high voltage files. Fifteen point seven millimetres of creepage does not come from the silicon, it comes from the package, and a board that copies a smaller isolated amplifier into this socket gains the creepage without changing the circuit. The reverse move does not work: a board qualified with the stretched body cannot substitute the narrow body without reopening the isolation and creepage numbers, even though the pins line up and the transfer function is the same.
Missing high side supply detection is worth wiring into the control loop on purpose. When the gate driver supply drops, the amplifier output goes to a defined level rather than floating, and the controller sees a current reading it can classify rather than a number that looks like a real current. In a drive this is the difference between a fault that is logged as a supply loss and one that is logged as an overcurrent trip, and the two lead to different maintenance actions.
- Shunt value against the loss at continuous current, with the thermal file open beside it.
- Offset and gain at 25 C on the first article, measured with the input shorted at the shunt.
- Common mode step response at the real bridge dv/dt, with the converter that will read the output.
- Creepage and clearance on the assembled board, measured rather than assumed from the package drawing.
- Behaviour with the high side supply removed, to confirm the control loop sees a defined level.
- Emissions scan with the amplifier running beside the radio, if the product has one.
Which projects this part fits
This part fits shunt based current sensing in motor drives and frequency inverters, solar and wind inverter phase current measurement, rail traction auxiliary converters, DC to DC converters in the hundreds of volts, and any inverter where the isolation file demands a specific creepage. It is the right part when the current signal is small, the common mode is violent and the safety file is strict. For customers moving a drive from a narrow body isolated amplifier, this is the substitution that keeps the transfer function and raises the creepage, and it is the one we quote when a certification body has already commented on spacing.
Questions that come up before a purchase order is released
Why is the gain 8.2 rather than a round number?
Because the output window is plus or minus 2.05 V from a plus or minus 250 mV input, which is what a 5 V converter with a plus or minus 2.5 V input window can read with headroom. A gain of 10 would give plus or minus 2.5 V, which sits exactly at the window edge, and any overshoot then clips. The odd number is a deliberate match to the converter, not a rounding error.
Can a 3.3 V system use this part on both sides?
Yes, the high side and the low side both run at 3.3 V or 5 V. At 3.3 V the output swing falls with the rail, so the plus or minus 2.05 V figure belongs to a 5 V low side. A 3.3 V low side needs a converter with a smaller window, or a different shunt, because the amplifier cannot swing above its rail.
Does the body change the electrical performance?
No. The die is the same as the narrow body member of the family, and the transfer function, the drift and the transient immunity are unchanged. What changes is the package capacitance, the creepage, the thermal path and the price. The narrow body is cheaper and smaller, and it is the right part when the isolation file does not need the spacing.
What is the difference between this part and a modulator?
This part gives an analogue output that a successive approximation converter reads, so the control loop sees a new value every conversion. A modulator gives a bit stream that needs a digital filter, which costs latency but delivers better resolution and noise shaping. A current loop that needs a fast trip wants the analogue part, and a metering channel that needs resolution wants the modulator.
How is the isolation verified on incoming parts?
The barrier is tested at the vendor, and at incoming inspection the practical checks are supply current on both sides, offset with the input shorted, and a functional transfer through the barrier with a known millivolt input. A barrier that has failed shows up as a channel with no transfer or as an abnormal supply current, and both are caught without a high voltage test set. A sample high voltage test belongs to the qualification file, not to every lot.
How SUPERB handles this line
We supply the AMC1400DWLR from original reels with lot traceability, and we check the marking and the body against the code because the stretched body shares a pinout with smaller members of the family. The power management cross reference page lists the isolated current and voltage families with the converters that read them, ADC and DAC cross reference covers the converter side, and incoming inspection plan sets out what to measure on a lot of isolated parts before they reach a production line.