TPS274C65ASHRHAR
Product Specifications
TPS274C65ASHRHAR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS274C65ASHRHAR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS274C65ASHRHAR quad 72 milliohm high side switch with SPI diagnostics
The TPS274C65ASHRHAR is a four channel smart high side switch in a 6 mm by 6 mm VQFN, built for industrial output modules. Each channel carries a 72 milliohm switch, an adjustable current limit, a demagnetisation clamp for inductive loads and a diagnostics path that reports load current digitally over SPI. The part is the answer to a specific problem: eight or sixteen outputs on one card, each of which has to survive a short to ground, a short to the supply and a broken wire, and each of which has to be diagnosable from the controller without a separate sense wire per channel.
The H in the string is the newer variant row. The family table splits the order codes by current limit set point: the AS and BS members cover 250 mA to 2.2 A, and the ASH member covers 290 mA to 2.45 A. The revision history of the document records that the comparison table and the electrical characteristics were extended for the H version, which is the trail to follow when a purchase order carries an unfamiliar string.
Key parameters taken from the TPS274C65 document
| Channels | Four, independent, each with its own current limit and diagnostics |
| On resistance | 72 milliohm per channel, which is what keeps a 2 A load inside the package thermal budget |
| Load range | 500 mA to 2 A DC per channel in the reference conditions |
| Current limit, AS and BS | Adjustable from 250 mA to 2.2 A |
| Current limit, ASH | Adjustable from 290 mA to 2.45 A |
| Inrush behaviour | Configurable period with a second, higher limit during turn-on for capacitive loads and lamps |
| Interface | SPI control and readback, isolated from the outputs by the serial link |
| Current sense | Integrated analog to digital conversion in the AS members, reported over SPI |
| Diagnostics | On state and off state open load, short to supply, short to ground, thermal warning |
| Inductive loads | Integrated output clamp that demagnetises an open load, above 65 V in the reference circuit |
| Protection | Current limit, thermal shutdown, short to ground, configurable fault handling |
| Package | VQFN RHA, 40 pins, 6 mm by 6 mm, 0.5 mm pitch |
| Temperature | Minus 40 to plus 125 degrees, as printed in the orderable addendum |
| Carrier | 2500 pieces on a large reel, moisture level 2 at 260 degrees |
The document also prints a pin function table that differs between the AS and ASH rows and the BS row, with several pins marked as do not connect on some versions. That table is the reason a cross reference cannot be done on pin count alone.
Where the numbers matter in a real build
Seventy two milliohm at 2 A is 288 milliwatt per channel. With four channels loaded at the same time in a sealed enclosure, the package has to get rid of more than a watt through a 6 mm body, and the copper under the thermal pad becomes part of the specification rather than a board house detail. The document gives a thermal information section with the board conditions attached, and a board that uses two layers with no thermal vias will land outside those conditions.
The second number is the current limit step. The ASH row tops out at 2.45 A where the AS tops out at 2.2 A. On a card that drives a 2 A solenoid with a 10 per cent tolerance, the difference decides whether the channel trips on a warm day. The inrush limit period is the second half of the same problem: a lamp or a capacitive load draws several times its steady current for the first milliseconds, and a single limit level would either trip on start-up or fail to protect the wiring.
The third is the diagnostics path. A broken wire on an off channel is invisible to a part that only measures current while it is on, so the off state open load detection is what turns a field return into a diagnostic code. The same is true of the short to supply case, which looks like a normal on state to a simple current sense.
- The version letter on the order, because the current limit ceiling and several pin functions move with it.
- The thermal pad copper area and via count against the board conditions in the thermal section.
- The inrush limit level and period, since both are set in registers rather than by a component.
- The SPI isolation barrier on the controller side, which the part supports because the interface carries data rather than an internal isolation stage.
- The clamp energy on an inductive load, because the integrated clamp has a current and an energy limit.
- The moisture level record, since the 6 mm body with a 0.5 mm pitch is sensitive to reflow profile.
Which projects this part fits
The document aims the part at industrial control systems and specifically at output modules that drive solenoids, lamps, contactors and valve pilot devices. The common requirement is a bank of outputs on one card with per channel diagnostics and a fault that must not take the whole card down.
Questions that come up before a purchase order is released
What is the difference between the AS, the ASH and the BS rows?
The AS and BS rows share a 250 mA to 2.2 A current limit range. The ASH row moves the ceiling to 2.45 A with a 290 mA floor. The pin function table also shows differences between the BS row and the AS rows.
Can the part drive an inductive load without an external clamp?
It carries an integrated clamp for demagnetisation, and the document describes the discharge behaviour. A load with more stored energy than the clamp can absorb still needs an external device.
Is the current sense accurate enough for a trip decision taken in the controller?
The sense path is described with its accuracy conditions in the electrical characteristics. A trip threshold set in the controller should come from the specified accuracy over temperature, not from a bench reading at room temperature.
Does the SPI interface need to be isolated?
The interface is what allows the controller to sit behind an isolation barrier, since load current is reported as a digital value. The barrier itself is a separate component on the card.
How SUPERB handles this line
Output modules of this kind are bought as a card: the switch, the clamp diodes, the connectors and the isolated SPI parts all have to arrive together for the line to run. Our power management cross reference covers the switch families this part is compared against. How to verify a drop in replacement sets out the checks before a second source goes on a released board, and our kitting service is the route for a bill of that shape.