ISO224BDWVR
Product Specifications
ISO224BDWVR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO224BDWVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO224BDWVR: The Reinforced Isolated Amplifier That Turns Plus or Minus 12 V Into Plus or Minus 4 V
ISO224BDWVR is a precision isolated amplifier for voltage sensing in a SOIC (DWV) body of 8 pins. It takes a plus or minus 12 V single-ended input on the high side and delivers a plus or minus 4 V differential output on the low side with a nominal gain of one third, so a 14 bit converter on the safe side can read a floating rail without a second divider.
Order code and package
| Ordering string | ISO224BDWVR |
| Grade | B, the high grade with the tighter offset and gain figures |
| Package | SOIC, 8 pins, DWV body, 5.85 mm by 7.50 mm nominal |
| Carrier | 1000 pieces on a large reel |
| Tube sibling | ISO224BDWV at 64 pieces in a tube, same die |
| Moisture level | Level 3, 260 C peak reflow, 168 hour floor life |
| Temperature range | Minus 55 to plus 125 degrees Celsius |
| Part marking | ISO224B |
| Analog input | Single-ended, plus or minus 12 V specified, plus or minus 13.8 V before the output clips |
| Analog output | Differential, plus or minus 4 V with the common mode at half the low side rail |
Electrical parameters that decide the application
| Nominal gain | 1/3 V per V, the ratio of the plus or minus 4 V output to the plus or minus 12 V input |
| Input offset voltage | Plus or minus 5 mV maximum at 25 degrees on the B grade |
| Input offset drift | Plus or minus 15 microvolts per degree maximum on the B grade |
| Gain error | Plus or minus 0.3 per cent maximum at 25 degrees on the B grade |
| Gain error drift | Plus or minus 35 parts per million per degree maximum on the B grade |
| Nonlinearity | Plus or minus 0.01 per cent maximum on the B grade |
| Input referred noise | 3 microvolts per root hertz typical on the B grade |
| Output bandwidth | 275 kHz typical on the B grade |
| Propagation delay | 2.2 microseconds typical from input to output on the B grade |
| Common mode transient immunity | 80 kV per microsecond typical on the B grade |
| High side supply | 4.5 to 18 V, a single supply |
| Low side supply | 4.5 to 5.5 V |
| High side decoupling | 0.22 microfarad between the VCAP pin and the high side ground |
| Isolation rating | 5000 VRMS for one minute per UL 1577, tested at 1.2 times for one second on every unit |
| Maximum repetitive peak voltage | 2121 VPK |
| Maximum working voltage | 1500 VRMS and 2121 VDC |
| Maximum transient voltage | 8485 VPK |
| Maximum surge voltage | 8000 VPK, tested at 1.6 times in qualification |
| External clearance | At least 8.5 mm, with 21 micrometres of insulation through the barrier |
| Barrier capacitance | About 1 pF from input to output |
| ESD on the input pin | Plus or minus 9 kV human body model, plus or minus 3 kV on the other pins |
Family variants and how they differ
| ISO224ADWVR | The lower grade, plus or minus 50 mV of offset, plus or minus 1 per cent of gain error and 30 kV per microsecond of immunity |
| ISO224BDWV | This die in a 64 piece tube |
| ISO224ADWV | The lower grade in a 64 piece tube |
| ISO224BDWVRG4 | This die on the same 1000 piece reel with the alternate finish paperwork |
| ISO7842FDWWR | A digital barrier when the signal is already digitised on the high side |
| ISO6731FDWR | A 50 Mbps triple when three digital lines have to cross instead of one analog channel |
Points to check before this part goes on a BOM
The high side runs from a single supply of 4.5 to 18 V. That is the feature that separates this part from the older isolated amplifiers, which needed a bipolar high side rail, and it removes one converter winding from the isolated supply.
Plus or minus 12 V is the specified input, and plus or minus 13.8 V is where the output starts to clip. A measurement that has to survive a transient above the specified range can, but the reading is no longer linear above 12 V and the firmware has to treat it as a fault rather than as a value.
The output is differential with the common mode at half the low side rail. That is what allows a cheaper converter to follow it, but the converter still has to accept a differential input, and a single-ended converter needs an amplifier stage that also sets the reference.
Offset and gain drift are quoted separately and both matter over temperature. On the B grade the drift is 15 microvolts per degree and 35 parts per million per degree, so an uncalibrated channel still holds a usable accuracy across a 100 degree swing, which the A grade does not.
The part is not a current sensor. Its input is a voltage across a shunt or a divider, and the input impedance and the external clamp are part of the measurement. The internal clamp protects the pin against short transients and is not a substitute for the external protection the application needs.
Where a one third gain is the right answer
Grid and traction measurements commonly work at plus or minus 10 V or plus or minus 12 V full scale, and the converter behind the barrier commonly works at plus or minus 2.5 V or with a 5 V reference. A gain of one third maps those two ranges onto each other with no external divider, which keeps the high side passive count low and the accuracy budget in the amplifier.
Where the full scale is smaller, a divider in front of the input costs offset and drift, so the choice is between a different amplifier and a different converter rather than between two resistor values.
The four pins on the high side
The high side has the input, the supply, the ground and the VCAP decoupling pin, and nothing else. There is no clock pin and no configuration, which is why the part can sit on a floating rail with only a regulator beside it. The 0.22 microfarad capacitor on VCAP is required, not optional, and it has to be a stable dielectric at the working temperature.
The high side supply detection is internal, so a rail that sags is visible to the system without an extra comparator. That matters in a protection relay, where a measurement channel that is silently out of range is worse than one that reports a fault.
Where this order code fits
It is chosen where a floating DC or low frequency voltage has to be measured accurately on a safe ground, most often in a protection relay, a motor drive DC link or a power analyser. Teams comparing it with a neighbouring part start from our Medical Device Components page, and teams replacing a part that has gone end of life start from the Strategic Sourcing page.
Questions buyers ask
Can the output drive a converter directly? It can drive a converter that accepts a differential input around half its own reference, which is what the plus or minus 4 V output with the common mode at half the low side rail is arranged for. A single-ended converter needs one more stage.
Why is the propagation delay 2.2 microseconds rather than nanoseconds? The channel is an analog amplifier with a 275 kHz bandwidth, not a digital isolator. A 2.2 microsecond delay is short for a measurement channel and slow for a control loop, so the part suits sensing rather than current loop control.
What separates the B grade from the A grade? Offset, drift, gain error, noise, bandwidth and common mode immunity. The B grade is 5 mV against 50 mV of offset, 0.3 per cent against 1 per cent of gain error, 275 kHz against 185 kHz of bandwidth and 80 kV against 30 kV per microsecond of immunity.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Supplier Scorecard page sets out the checks that keep a substitute from failing on the bench.