INA826AID
Product Specifications
INA826AID
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA826AID from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA826AID: 200 microamp instrumentation amplifier with a rail to rail output
INA826AID is a low power instrumentation amplifier with a rail to rail output stage in a SOIC body of 8 pins. The input common mode range includes the negative rail, the output swings to both rails, and the supply current is 200 microamps, all from a 3 V to 36 V supply. One resistor sets the gain with the 1 plus 49.4 kiloohm over RG relation, and the inputs take 40 volts beyond the rails without damage.
Order code and package
| Order code | INA826AID |
| Function | low power instrumentation amplifier |
| Gain | set by one external resistor, 1 plus 49.4 kiloohms over RG |
| Package | SOIC, 8 pins |
| Other bodies | 8 pin VSSOP and 8 pin WSON |
| Supply | 3 V to 36 V single, plus and minus 1.5 to 18 V |
| Supply current | 200 microamps |
| Input common mode | includes the negative rail |
| Input protection | plus or minus 40 V beyond the rails |
| Output | rail to rail |
| Bandwidth | 1 MHz at gain 1, 60 kHz at gain 100 |
| Datasheet | SBAS435 revision D |
Electrical parameters that decide the application
| Offset voltage | 150 microvolts maximum |
| Gain drift | 1 ppm per C at gain 1, 35 ppm per C above gain 1 |
| Common mode rejection | 104 dB minimum at gain 10, 100 dB at 5 kHz |
| Power supply rejection | 100 dB minimum at gain 1 |
| Noise | 18 nanovolts per root hertz at gains of 100 and above |
| Temperature range | minus 40 to plus 125 C |
| Input bias current | specified for a bridge source with a return path to ground |
| Output swing | within tens of millivolts of each rail at light load |
| Stability | stable into a capacitive load with a small series resistor |
| Family position | the low supply current, rail to rail output member of the 49.4 kiloohm line |
Points to check before this part goes on a BOM
An input range that includes the negative rail is what lets a single supply board read a ground referenced bridge. Most instrumentation amplifiers need the input lifted above ground, and that lift costs a reference and two resistors that this part does not need.
The 150 microvolt maximum offset is ten times the typical figure of the wideband parts and it is the price of the rail to rail input stage. On a 350 ohm bridge with a 2 millivolt span, that offset is 7 percent of full scale before any gain.
Gain drift of 1 ppm per C at unity jumps to 35 ppm per C once the external resistor sets the gain. The jump is the resistor, and a 25 ppm per C resistor makes the total drift worse than the datasheet row.
Sixty kilohertz at gain 100 is enough for a temperature loop and not for a dynamic measurement. A flow meter with a 1 kilohertz vortex signal has margin, a vibration channel with 20 kilohertz does not.
Two hundred microamps of supply current at 3 V is 600 microwatts, which is what a loop powered transmitter can spend on its front end. The converter behind it usually wants more than the amplifier, so the budget has to be split before the parts are chosen.
The rail to rail output is quoted at light load. Driving a 10 kiloohm converter input holds the swing, and driving a 1 kiloohm load pulls the top of the range in by tens of millivolts, which matters on a 12 bit converter.
Where this order code fits
Analog input modules, flow transmitters and battery test channels are the usual boards, where the signal sits near ground and the supply is a single 5 V rail. Boards comparing it with a neighbouring part start from our Amplifier Cross Reference page, and boards replacing a part that has gone end of life start from the One Stop BOM Sourcing page.
Questions buyers ask
Can it read a bridge with one side at ground? Yes. The input common mode range includes the negative rail, which is the case this part was built for; the reference pin then sets where zero load appears at the output.
Is 150 microvolts of offset a maximum or a typical? It is a maximum, and the typical is lower; a project that needs tighter offset moves to the wideband parts in this line rather than trimming this one.
SUPERB holds and sources this Texas Instruments line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a line is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.