Contact Us

INA181A2QDBVRQ1

Brand: Texas Instruments
Texas Instruments INA181A2QDBVRQ1 is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

INA181A2QDBVRQ1 — Power Management & Signal Chain | Superb Automation

INA181A2QDBVRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA181A2QDBVRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA181A2QDBVRQ1: the automotive 50 V/V member, marking 1MS3

INA181A2QDBVRQ1 is the automotive member of the 50 V/V current sense amplifier in the six pin SOT-23, on a 3000 piece large reel, marked 1MS3. It is AEC-Q100 grade 1, specified from minus 40 to plus 125 degrees, with HBM level 2 and CDM level C6, and its moisture level is 1 with a 260 degree peak and no floor life limit, which the plain rows of the same body do not carry.

The electrical table is the same as the non automotive part, row for row, so a channel characterised on the plain part does not need a new characterisation. What the Q1 adds is the qualification, the temperature grade, the moisture level and the paperwork, and those four are the reason an automotive customer will not accept the plain code on a deviation.

INA181A2QDBVRQ1 as the vendor document publishes it

Gain50 V/V
QualificationAEC-Q100 grade 1, HBM level 2, CDM level C6
Common mode rangeminus 0.2 to plus 26 volts, independent of the supply
Supply range2.7 to 5.5 volts
Common mode rejection84 dB minimum, 100 typical
Offset at zero common mode25 microvolts typical, 150 maximum
Offset at 12 volts of common mode100 microvolts typical, 500 maximum
Offset drift0.2 microvolts per degree typical, 1 maximum
Supply rejection8 microvolts per volt typical, 40 maximum
Input bias current6 microamps at zero common mode, 75 at twelve volts
Gain error0.1 per cent typical, 1 maximum over temperature
Gain drift1.5 ppm per degree typical, 20 maximum
Bandwidth210 kHz with a 10 picofarad load
Slew rate2 volts per microsecond
Voltage noise40 nanovolts per root hertz
Output swing to supplywithin 20 millivolts typical, 30 maximum into 10 kohm
Quiescent current195 microamps typical, 260 maximum, 300 over temperature
Moisture levellevel 1, 260 degrees, unlimited floor life on the Q1 rows
Bodysix pin SOT-23, DBV, marking 1MS3
Temperature rangeminus 40 to plus 125 degrees
Catalogue codeINA181A2QDBVRQ1
Vendor stringINA181A2QDBVRQ1
Carrier3000 piece large reel
Marking1MS3, moisture level 1 unlimited

SOT-23, SC70 and the automotive flow

INA181A2QDBVRQ1 comes in two six pin bodies: the DBV, which is the SOT-23 at 2.9 by 2.8 millimetres, and the DCK, the SC70 at 2.0 by 2.1. The die is the same and the pinout is nearly the same, but the thermal resistance is not: 188 degrees per watt for the SOT-23 against 198 for the SC70 on the single channel, and the reel quantities differ between the grades, which is why the body and the carrier belong on the order line rather than in a note.

The Q1 suffix marks the automotive flow, and that is a separate document with its own rows. The automotive part is AEC-Q100 grade 1, specified from minus 40 to plus 125 degrees, with HBM level 2 and CDM level C6, and the addendum prints the MSL as level 1 unlimited for the Q1 rows where the plain part carries a different level. The electrical table is the same in both documents, so a channel qualified on the plain part does not need a new characterisation for the automotive one, only a new part number and a new set of paperwork.

Four fixed gains: 20, 50, 100 and 200

INA181A2QDBVRQ1 is one of four gain options in a single current sense amplifier family, and the letter after the A is the gain: A1 is 20 V/V, A2 is 50, A3 is 100 and A4 is 200. All four share the same die, the same six pin bodies and the same 2.7 to 5.5 volt supply, so the choice is made once, from the shunt value and the converter range, and does not change anything else on the board.

The choice is arithmetic. A 10 milliohm shunt carrying 5 amps develops 50 millivolts, which at a gain of 50 is 2.5 volts and fills a 3.3 volt converter's range; the same shunt with a gain of 20 gives 1 volt and wastes two thirds of the range; with a gain of 200 it gives 10 volts and clips. Because the gain error is 1 per cent maximum at every option, the gain does not buy accuracy, only scale, and the option with the largest signal at the converter is always the right one.

Minus 0.2 to plus 26 volts of common mode on a 5 volt supply

The common mode range of INA181A2QDBVRQ1 is minus 0.2 to plus 26 volts, independent of the supply, which is what allows a 26 volt bus to be measured by a part running from 3.3 volts. The negative end matters as much as the positive one: minus 0.2 volts means the amplifier still works when the shunt is on the low side and the ground return lifts by a diode drop or by the voltage across a trace, and it means a bidirectional measurement can swing through zero without a dead band.

Rejection over that window is 84 dB minimum and 100 typical, measured with the inputs at 0 to 26 volts and no differential signal. That is a lower figure than a dedicated high voltage monitor publishes, and it is the row that decides whether a 26 volt bus with 1 volt of ripple can be measured to 1 per cent: 1 volt of ripple divided by 10 to the 4.2 is 63 microvolts at the input, which at a gain of 50 is 3 millivolts at the output against a 2.5 volt full scale, 0.13 per cent. It is the switching transients rather than the ripple that usually break that budget.

One per cent of gain error, and what it costs a current reading

Gain error on INA181A2QDBVRQ1 is 0.1 per cent typical and 1 per cent maximum over minus 40 to plus 125 degrees, with 1.5 ppm per degree typical and 20 maximum of gain drift and 0.01 per cent of nonlinearity. The 1 per cent is a maximum over temperature rather than at 25 degrees, which is the figure a specification should quote, and the drift row is the part that a single point calibration cannot remove.

What 1 per cent means depends on where the channel sits in its range. At full scale it is 1 per cent of the reading. At a tenth of full scale it is still 1 per cent of the reading and the offset becomes the larger term: 150 microvolts of offset at a gain of 50 is 7.5 millivolts at the output, which against a 250 millivolt reading is 3 per cent. That is why a current monitor is specified over a range rather than at a point, and why the shunt is chosen to put the working current near the top of the amplifier's range rather than in the middle.

350 kHz at 20, 105 kHz at 200

Bandwidth on INA181A2QDBVRQ1 falls with the gain option: 350 kHz for A1, 210 kHz for A2, 150 kHz for A3 and 105 kHz for A4, all with a 10 picofarad load, with a slew rate of 2 volts per microsecond and 40 nanovolts per root hertz of input referred noise. Output swing is within 20 millivolts of the positive rail typical and 30 maximum into a 10 kohm load, and within 0.5 to 5 millivolts of ground, which is what makes a 3.3 volt rail usable from end to end.

For a motor or a battery current that bandwidth is more than enough, and for a switching supply it is the number that decides whether the monitor sees the ripple or the average. At 350 kHz a 100 kHz switching ripple is passed with a few degrees of phase shift; at 105 kHz it is attenuated, and a current loop closed through the monitor then has a pole it did not expect. The noise figure translates the same way: 40 nanovolts per root hertz over a 100 kHz bandwidth is 12.6 microvolts RMS, which at a gain of 200 is 2.5 millivolts at the output.

One hundred and fifty microvolts at zero common mode, five hundred at twelve volts

The offset of INA181A2QDBVRQ1 is quoted twice because it depends on the common mode: 25 microvolts typical and 150 maximum with the inputs at zero volts, 100 and 500 microvolts with the inputs at 12 volts. Drift is 0.2 microvolts per degree typical and 1 maximum, supply rejection is 8 microvolts per volt typical and 40 maximum, and the input bias current is 6 microamps at zero common mode rising to 75 microamps at 12 volts, with 0.05 microamps of offset current.

The bias current row is the one that surprises people. 75 microamps flowing in the shunt's own resistance is 75 microvolts across a 1 milliohm shunt, which at a gain of 50 is 3.75 millivolts at the output and 0.15 per cent of a 2.5 volt full scale, and it changes with common mode rather than staying constant. On a shunt below a milliohm that term is comparable with the offset, and it is why the vendor's board guidance asks for the input traces to be matched and kept away from the shunt's Kelvin connections.

On an automotive build the qualification documents travel with the parts, so the quote should name them. Our traceability report page covers what travels with the reel, and the incoming inspection plan covers the paperwork check on arrival.

Is the Q1 part electrically different? No. The electrical table is identical to the plain part; the qualification, temperature grade and moisture level are what differ.