INA126UA
Product Specifications
INA126UA
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA126UA from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA126UA: the A grade SOIC body in a 75 piece tube
The INA126UA is the A grade of the eight pin SOIC body in a 75 piece tube, which makes it the calibrated prototype carrier of this family. The A suffix marks the tighter offset and gain error bin on the same die, so the code is chosen when the channel full scale is small enough that 250 µV of offset would need a trim circuit and the tighter bin removes the trim or shrinks it. The tube is the carrier that matches a bench build rather than a production run.
Everything else is the family: a two op amp instrumentation amplifier with a gain floor of 5, 175 µA per channel, plus or minus 1.35 V to plus or minus 18 V, 3 µV per degree of drift and 25 nA of bias current. The part is comfortable on a bridge or a thermocouple channel sampled a few times a second, and the bandwidth at the gain in use is the number that limits a faster channel.
The INA126UA rows as the addendum publishes them
| Part class | Micropower instrumentation amplifier, two op amp, single channel |
| Vendor status | Active, production |
| Data sheet | SBOS062D, revised December 2025 |
| Grade | A suffix, tighter offset and gain error window |
| Gain equation | G = 5 + 80 kΩ divided by RG |
| Gain range | 5 to 10,000 V/V |
| Input offset voltage | Family row 250 µV maximum, tighter on the A bin |
| Offset drift | 3 µV per degree maximum, both grades |
| Input bias current | 25 nA maximum, both grades |
| Bandwidth | 200 kHz at a gain of 5, 9 kHz at a gain of 100 |
| Overload recovery | 4 µs from a 50 per cent input overload |
| Supply range | Plus or minus 1.35 V to plus or minus 18 V |
| Quiescent current | 175 µA typical per channel |
| Body | SOIC, D outline, 8 pins |
| Carrier | 75 pieces per tube |
| Moisture level | Level 2, 260 degrees, one year floor life |
| Temperature range | Minus 40 to plus 85 degrees |
| Lead finish | Nickel palladium gold on the published rows |
250 µV of offset and 3 µV per degree of drift on a bridge channel
The offset row for this family is 250 µV maximum on the plain parts and tighter on the A grade, and the drift row is 3 µV per degree maximum. Against a 10 mV full scale bridge those numbers are 2.5 per cent of range and 0.03 per cent per degree, so the offset is trimmed at the bench and the drift is lived with. Against a 100 mV full scale the offset is a quarter of a per cent and the drift is negligible, which is the region where the part is comfortable and where most pressure and flow transmitters actually sit.
The comparison that matters is against the amplifier the part replaces. A general purpose op amp pair built into an instrumentation front end can easily carry 1 mV of offset and 10 µV per degree, and at that level the drift, not the bridge, sets the annual recalibration interval. Moving to a trimmed instrumentation amplifier buys the interval back. The other half of the budget is the bridge excitation: a 5 V excitation on a 350 Ω bridge draws 14 mA, which is two orders of magnitude more than INA126UA draws, so the current budget is set by the sensor rather than by the amplifier.
Two op amp topology and why the gain floor is 5
The INA126 is a two op amp instrumentation amplifier rather than the three op amp arrangement used by the larger instrumentation parts, and that choice explains most of what is unusual about it. The first stage is a pair of amplifiers sharing one gain resistor, and the second stage is a difference amplifier that removes the common mode. Fewer amplifiers means less supply current, and it also means the gain cannot go all the way down: the minimum stable gain is 5, and the vendor states that a minimum circuit gain of 5 is what keeps the dc common mode range and the bandwidth usable. On INA126UA there is no resistor value that gives unity gain, so a channel that needs a buffer is a different part.
The gain equation is G = 5 + 80 kΩ divided by RG, which is a different shape from the 1 + 50 kΩ form used by the INA128 family. The five is inside the equation, so the external resistor only ever adds to a gain that is already 5. At a gain of 100 the resistor is 842 Ω, at a gain of 1000 it is 80.4 Ω, and at the top of the range the resistor is a couple of ohms, which is where the resistance of the socket and the wiring starts to matter as much as the resistor itself.
The 80 kΩ term, 0.1 per cent resistors and the resistance you forgot
Gain accuracy on INA126UA is set by the external resistor and by the 80 kΩ term inside the equation, and the internal term is trimmed. What is not trimmed is the resistance from the RG pins to the resistor itself: the socket, the solder joint, the trace and the resistor lead all sit in series with RG, and at a gain of 1000 where RG is 80 Ω a single ohm of that path is 1.25 per cent of gain error. That is why the vendor note says sockets and wiring resistance matter at high gain, and why the resistor should be placed within a few millimetres of the pins.
The resistor itself should be a 0.1 per cent metal film part with a 25 ppm per degree coefficient, and it should be the same type on every channel of a multi channel board so that the channels track rather than each drifting its own way. A 1 per cent resistor at a gain of 100 contributes 1 per cent of gain error before temperature, which is larger than the amplifier gain error row. The cost difference between a 1 per cent and a 0.1 per cent resistor is a few cents, and it is the cheapest accuracy in the whole channel.
175 µA per channel and the supply window that comes with it
At 175 µA per channel typical and 200 µA maximum, INA126UA is built for a product that runs from a battery or from a loop supply, and the supply window of plus or minus 1.35 V to plus or minus 18 V is what makes that possible. The bottom of the window is low enough that a pair of fresh alkaline cells in series will run the part directly, and the top is high enough for a plus or minus 15 V industrial rack. Nothing in between needs a regulator, which is the point: a channel that does not need a regulator does not need the quiescent current of one either.
The current is quoted per channel and with no load, so the total for a dual INA2126 is twice the figure. What the number does not include is the reference divider. A single supply channel needs a mid rail reference, and a 10 kΩ divider across 5 V draws 250 µA, which is more than the amplifier itself. A 100 kΩ divider draws 25 µA and needs a capacitor to hold it stiff; that trade is made once per board rather than once per channel, and it decides whether the microamp budget survives.
Running from plus or minus 1.35 V and what stops working
The supply floor of plus or minus 1.35 V is the reason this family appears in battery instruments, and it comes with conditions. The input common mode window is quoted relative to the rails and does not shrink with the supply, so at plus or minus 1.35 V the window is roughly plus or minus 0.35 V of usable common mode, which is enough for a bridge running at a 0 V common mode and not enough for anything referenced to the positive rail. The output swing also stops about 0.8 V short of each rail, so the usable signal swing at the floor is under a volt peak to peak.
On a 3 V single supply the same arithmetic gives a 1.5 V reference and a signal window of about a volt, which is workable for a strain gauge and marginal for a thermocouple. The part is not a rail to rail amplifier and should not be treated as one. What the low supply does buy is headroom against a dying battery: the amplifier keeps working while the rail falls, and the failure mode is a signal that runs out of range rather than an amplifier that stops.
Plain grade against A grade on the same die
The A suffix on the PA, UA and EA rows is a tighter offset bin, not a different silicon. Both grades share the 3 µV per degree drift, the 25 nA bias current and the 175 µA supply current, and they differ in the maximum offset and in the gain error window. On a channel with a 10 mV full scale the plain grade consumes 2.5 per cent of the range before trimming and the A grade consumes half of that, which is the difference between a trim circuit that is a convenience and one that is mandatory.
Because the two grades are pin compatible, the choice is made on the specification rather than on the board, and that makes substitution easy in both directions and dangerous in one. Shipping the A grade where the plain grade was ordered costs money and raises no objection. Shipping the plain grade where the A grade was ordered passes incoming inspection only if nobody measures the offset, and fails at the first temperature cycle if somebody does. The grade should therefore sit on the purchase order line rather than in a note.
Buying INA126UA in the tube
The A grade is bought for one reason: to keep the offset inside a specification that the plain grade would exceed. On a 10 mV full scale the plain grade uses 2.5 per cent of the range and the A grade roughly half of that, so the question is whether the channel has a trim at all. A channel with a trim can use either grade; a channel without one needs the A grade and a specification written around it.
The tube is the carrier for a bench build, and 75 pieces covers a few hundred channels with spares. A production run beyond that moves to the reel rows of the same die, which carry a different moisture level and a different handling rule. Our component lead time page covers how the tube and the reel lines are scheduled, and the date code management page covers the storage rule for both.
Questions that arrive with this part number
Whether the A grade is worth the price difference is the first question, and the honest answer is that it depends on the full scale and on whether there is a trim. On a 100 mV full scale the plain grade is 0.25 per cent of range and the A grade is unnecessary. The second question is whether the grade is visible on the part, and it is not in any way a customer can read without the label, so the receiving inspection has to trust the carrier and the marking rather than a visual check.
The third is about the gain floor. The family cannot run at a gain below 5, and a channel that needs unity gain needs a buffer and then this amplifier, or a different part. That constraint comes from the two op amp topology and applies to every code on this page family.