Contact Us

INA116UA

Brand: Texas Instruments
Texas Instruments INA116UA is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

INA116UA — Power Management & Signal Chain | Superb Automation

INA116UA

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA116UA from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA116UA: the femtoamp amplifier in a 16 pin SOIC, marked NRND

The INA116UA is the surface mount version of the ultra low bias current instrumentation amplifier, in the 16 pin wide body SOIC. The specification is the reason the part exists: 3 fA of typical input bias current at 25 degrees, 25 fA at 85 degrees, buffered guard drive pins beside each input, 2 mV of maximum offset, 84 dB of common mode rejection at a gain of 10, 1 mA of quiescent current and 40 V of input protection. The gain range is 1 to 1000 on a single resistor.

The status is not recommended for new builds. That is a statement about the vendor's plan rather than about the part's performance: the die is the same one that has been in pH and ion selective probe instruments for decades, and the reason to stop using it is that a modern electrometer amplifier does the same job in a smaller body with a lower supply current. The reason to keep using it is that the guard arrangement and the board around it already exist and are qualified.

The INA116UA rows as the addendum publishes them

Part classFET input instrumentation amplifier, ultra low bias current
Vendor statusNRND, not recommended for new builds
Data sheetSBOS034
Input bias current at 25 degrees3 fA typical
Input bias current at 85 degrees25 fA typical
Input offset voltage2 mV maximum
Common mode rejection at G = 1084 dB
Quiescent current1 mA
Input overvoltage protection40 V without damage
Gain equationG = 1 + 50 kΩ divided by RG
Gain range1 to 1000 V/V
Guard pinsBuffered guard drive at both inputs
BodySOIC, DW outline, 16 pins
Carrier40 pieces in a tube
RoHSYes
Lead finishNickel palladium gold
Moisture levelLevel 3 at 260 degrees, 168 hour floor life
Temperature rangeMinus 40 to plus 85 degrees
Part markingINA116UA
Revision rowINA116UA.A, NRND as well
Green rowINA116UAG4, also NRND
Sibling stringINA116PA in the plastic DIP, last time buy

Three strings, all NRND or last time buy, which is what the end of a product life looks like on an addendum. The G4 suffix is the green material declaration and it does not change the status. A buyer who sees the G4 row and assumes it is the current one should read the status column rather than the suffix.

Board leakage against a 3 fA amplifier

A 3 fA bias current is smaller than the leakage of most solder fluxes, and that is the engineering reality of this part. A board that is cleaned with an aqueous process and then handled without gloves will show picoamps of leakage, and the amplifier's own bias current is then invisible. The guard ring, the conformal coat and the cleaning process are all part of the specification, and a customer who buys this part to fix a leakage problem usually finds that the leakage is on the board rather than in the amplifier.

The SOIC body has one advantage over the plastic DIP here: the shorter lead length reduces the surface path between pins, and the smaller package makes a guard ring easier to route tightly around the two inputs. On a high impedance channel the package that lets the guard sit closest to the pins is the better package, and that is this one.

The guard buffer and cable capacitance

The guard pins are driven by an internal buffer that follows the input, and the buffer is specified for a cable shield of a few hundred picofarads. Beyond that the buffer becomes slow and the guard lags the input during a step, which converts the guard into a leakage path for the duration of the step. A series resistor of 10 kΩ in the guard line isolates the capacitance and costs a slower settling, which is the usual compromise on a long probe cable.

The guard has to be continuous from the pin to the connector, and a ground plane under the guard is not a substitute. A guard on the top layer with a ground plane below is a capacitor to ground, which at 50 Hz is a low impedance path and defeats the purpose. The correct arrangement is a guard on both sides of the input trace with the plane cleared underneath.

Migrating off this part

A modern electrometer amplifier will have a bias current in the same range and a smaller body, and the migration is a board change with three parts of work: the footprint, the guard routing, and the supply. The supply is the one that surprises people, because many modern parts run from a single 5 V rail and the guard arrangement changes with the rail. A channel that was built around a plus or minus 15 V supply has to be reworked around the new supply, and the probe bias may have to change with it.

Where the instrument is in production and qualified, the NRND status is not a reason to change anything today, and the right action is a documented last time buy through the DIP sibling or a stock position on this string. Where the instrument is being revised anyway, the migration is worth doing in the same revision rather than in a separate project later.

Buying INA116UA

The tube is 40 pieces and the part is level 3, so an opened tube has a 168 hour window. On a low volume instrument that builds fifty boards a quarter, one tube covers more than a year, and the part will be out of the tube and on the shelf for most of that time. A dry pack between builds is the only way to keep the floor life honest.

Stock is finite and the price reflects the status. A customer who needs a hundred pieces should ask for a date code and a country of origin with the quotation, and should not accept a shipment without a photograph of the tube label.

Questions that arrive with this part number

The first is whether the UA and the PA are the same die, and they are, in different bodies with different end of life statuses. The second is whether the part can run from a single 5 V supply. It can, within the supply range, but the common mode range and the guard behaviour have to be checked at that rail rather than assumed from a plus or minus 15 V bench.

The third is whether a modern part is a drop in replacement. It is not, and the board change is the project.

For a customer planning the migration, our obsolete part cross reference hub lists the candidates we compare, and the obsolescence management page sets out how a stock position is planned against a remaining product life.

The guard on this body has one more constraint that the through hole version does not: the pins are closer together, so the guard trace between the two inputs is short and easy to route, but the trace to the guard pin passes close to the supply pins. A supply pin next to a guard pin is a leakage path at the full rail voltage, and on a femtoamp channel that path is the one that dominates. The guard trace should leave the pin on the opposite side from the supply and go straight to the input pair rather than looping around the package.

A second point is the conformal coat. A coated board holds its leakage current at a stable value, which is easier to calibrate out than a value that moves with the weather. A board that is not coated will pass on a dry day and fail on a wet one, and the failure will be attributed to the amplifier rather than to the environment.