DRV5055A3QDBZR
Product Specifications
DRV5055A3QDBZR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV5055A3QDBZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV5055A3QDBZR: ratiometric linear Hall sensor with 25 mV per mT sensitivity and 20 kHz bandwidth
DRV5055A3QDBZR is a linear Hall effect sensor with a ratiometric analogue output that moves 25 mV per millitesla around a mid supply quiescent point, with 20 kHz of sensing bandwidth and a sensitivity grade selected by the order code in a SOT-23 body of 3 pins. The DRV5055 measures magnetic flux density and puts out an analogue voltage that is proportional to it, centred on half the supply. At 5 V the A3 grade gives 25 mV per millitesla over a range of plus or minus 85 mT, and the A versions include compensation for the temperature drift of a neodymium magnet while the Z versions do not. Bandwidth is 20 kHz, the output drives 1 mA, and the part runs from 3.3 V or 5 V in a 3 pin SOT-23.
Order code and package
| Order code | DRV5055A3QDBZR |
| Sensitivity at 5 V | 25 mV per mT |
| Measurement range at 5 V | plus or minus 85 mT |
| Quiescent output | half of VCC |
| Sensing bandwidth | 20 kHz |
| Output drive | plus or minus 1 mA |
| Supply | 3.3 V or 5 V |
| Temperature compensation | included on the A versions, absent on the Z versions |
| Package | 3 pin SOT-23, DBZ body |
| Pin count | 3 |
| Document | SBAS646, linear Hall sensor family, revision current at download |
Electrical parameters that decide the application
| Supply absolute maximum | 7 V |
| Output absolute maximum | -0.3 V to VCC plus 0.3 V |
| Operating ambient range | -40 C to 125 C |
| Junction range | -40 C to 170 C |
| Sensitivity grades at 5 V | A1 100 mV per mT, A2 50, A3 25, A4 12.5, A8 66 |
| Ranges at 5 V | A1 plus or minus 21 mT, A2 42 mT, A3 85 mT, A4 169 mT, A8 75 mT |
| Output swing at 5 V, A3 | about 0.375 V to 4.625 V for the full range |
| Sensitivity at 3.3 V, A3 | about 16.5 mV per mT, range about plus or minus 56 mT |
| Storage temperature | -65 C to 150 C |
Points to check before this part goes on a BOM
The output is ratiometric, so the sensitivity scales with the supply. The A3 grade is 25 mV per mT at 5 V, which becomes about 16.5 mV per mT at 3.3 V, and the usable range falls from plus or minus 85 mT to about plus or minus 56 mT because the output can only swing so far around mid supply. A product that runs the same magnet and the same firmware on both rails has to scale the reading by the measured supply, not by a constant.
The A and Z suffixes are a real functional difference. The A versions compensate for the average temperature drift of a neodymium magnet, so the reading tracks the field rather than the magnet; the Z versions leave that drift in the signal. A product that calibrates at 25 C and runs to 85 C will see the magnet drift appear as a position error on a Z part and much less on an A part, which is why the A grades cost more.
Twenty kilohertz of bandwidth sets the sampling rule. A converter reading this output needs at least 40 kSPS to avoid aliasing the sensor's own noise, and a 12 bit converter at that rate sees the full noise band. The datasheet's own advice is to add a filter when the full bandwidth is not needed, because a single pole at 2 kHz removes most of the noise and still leaves 100 times the bandwidth of a mechanical actuator.
Mid supply quiescence is convenient and it is also a limit. The output sits at VCC/2 with no field, so the usable swing is roughly from 0.4 V to VCC minus 0.4 V. At 3.3 V that is a 2.5 V window, which is plus or minus 1.25 V, and at 25 mV per mT scaled to 3.3 V that is the 56 mT figure. A system that needs 100 mT of range on a 3.3 V rail has to move to a lower sensitivity grade rather than to a higher supply.
Sensitivity tolerance and linearity are specified separately from the range, and the quiescent point has its own drift over temperature and over life. A ratiometric sensor's offset error appears directly as a position offset, so a system that needs absolute position has to calibrate the midpoint at least once. The datasheet publishes a quiescent voltage temperature drift parameter, which is the number to use for that error budget rather than the sensitivity figure.
A 3 pin SOT-23 with a 1 mA output drive can be placed close to the magnet and far from the converter, which is the usual arrangement in a pedal or a valve. The output is a single ended voltage, so the return path carries the sensor current and the wiring resistance appears in the reading; a differential converter input or a remote ground sense removes that error. The 7 V absolute maximum on the supply is low enough that a 5 V rail with a hot plug transient can exceed it, so a series resistor and a clamp are cheap insurance.
Ordering the A3 code fixes the sensitivity grade and the compensation. The same package with an A4 code is 12.5 mV per mT and plus or minus 169 mT, and an A1 is 100 mV per mT and plus or minus 21 mT, so a reel mix up shows up as a reading that is off by a factor of two or four. The grade is printed on the reel label and on the part marking, and a second source check has to compare the full code rather than the DRV5055 prefix.
Where this order code fits
This order code suits position and travel sensing in actuators, pedals, throttles and valves, plus current sensing, fluid flow measurement and angle encoding where a small magnet moves past a fixed sensor. The ratiometric output means the reading follows the supply, so a 3.3 V and a 5 V version of the same product share one transfer function after scaling. Boards comparing it with a neighbouring part start from our IMU Selection Guide page, and boards replacing a part that has gone end of life start from the How to Verify a Drop in Replacement page.
Questions buyers ask
What happens at 3.3 V instead of 5 V? The sensitivity and the range both scale with the supply, to about 16.5 mV per mT and plus or minus 56 mT for the A3 grade. The reading has to be scaled by the actual supply voltage.
Should I choose an A or a Z grade? Choose A when the magnet runs over temperature and the reading has to track the field. Choose Z when the drift of the magnet is calibrated out in the system or does not matter.
How fast can the output be sampled? The bandwidth is 20 kHz, so 40 kSPS or more avoids aliasing. Add a filter if the mechanical movement is much slower than that.
SUPERB supplies this order code in the DBZ tape and reel with date codes, packing and country of origin on the offer, and the BOM Shortage Recovery page sets out the checks that keep a grade mix up from reaching a production line.