Product Specifications

CC1125RHBR — Power Management & Signal Chain | Superb Automation

CC1125RHBR

Texas Instruments — Power Management & Signal Chain

Product Overview

The CC1125RHBR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

CC1125RHBR: narrowband sub 1 GHz transceiver with plus 16 dBm output and 200 kbps data rate

CC1125RHBR is a single chip narrowband transceiver in the 32 pin RHB body that covers 164 MHz to 192 MHz, 410 MHz to 480 MHz and 820 MHz to 960 MHz, transmits up to plus 16 dBm in 0.4 dB steps and receives with 67 dB of adjacent channel selectivity at a 6.25 kHz offset in a QFN body of 32 pins. The CC1125 is a narrowband transceiver for the licensed and licence free bands below 1 GHz. Three frequency ranges are covered, the data rate runs from 0 to 200 kbps in packet mode, and the modulation set includes 2-FSK, 2-GFSK, 4-FSK, 4-GFSK, MSK and OOK. Output power is programmable to plus 16 dBm in 0.4 dB steps with automatic ramping, and the body is a 5 mm by 5 mm QFN with a 32 MHz or 40 MHz crystal depending on the band.

Order code and package

Order codeCC1125RHBR
Functionnarrowband sub 1 GHz transceiver
Frequency ranges164 to 192 MHz, 410 to 480 MHz, 820 to 960 MHz
Data rate0 to 200 kbps in packet mode, 0 to 100 kbps transparent
Modulation2-FSK, 2-GFSK, 4-FSK, 4-GFSK, MSK, OOK
Output powerup to plus 16 dBm in 0.4 dB steps
Package32 pin QFN, 5 mm by 5 mm
Crystal32 MHz or 40 MHz depending on band
DocumentSWRS120E, June 2011, revised October 2014
Supply voltage3.0 V nominal in the published characteristics

Electrical parameters that decide the application

Adjacent channel selectivity67 dB at a 6.25 kHz offset
Blocking at a 10 MHz offset104 dB
Saturation levelplus 10 dBm
Image rejection with compensation58 dB
TX current at plus 14 dBm, 868 MHz to 920 MHz47 mA
TX current at plus 10 dBm, 868 MHz to 920 MHz38 mA
TX current at plus 15 dBm, 434 MHz51 mA
TX current at plus 10 dBm, 950 MHz band37 mA
RX peak current, 433 MHz to 920 MHz26 mA
RX peak current, 169 MHz band27 mA
Idle mode current1.3 mA
Data rate in packet mode0 to 200 kbps
Frequency resolution, 820 to 950 MHz30 Hz
Frequency resolution, 410 to 480 MHz15 Hz
Frequency resolution, 164 to 192 MHz6 Hz

Points to check before this part goes on a BOM

Sixty seven decibels of adjacent channel selectivity at a 6.25 kHz offset is the number that separates a narrowband transceiver from a general purpose one. In a band where channels are 12.5 kHz apart and a neighbouring transmitter can be metres away, the receiver has to reject a signal that is tens of decibels stronger than the one it wants, and a part with 40 dB of selectivity simply hears the neighbour. The blocking figure of 104 dB at a 10 MHz offset describes the same problem at the other end of the scale, where a broadcast transmitter or a base station is far away but far stronger.

A saturation level of plus 10 dBm means the receiver survives being close to a transmitter without its input stage folding over. That is a specification for a shared site rather than for a bench: two nodes mounted on the same pole, one transmitting and one receiving, put far more than plus 10 dBm into the receiving antenna unless the antennas are separated or the transmit power is reduced. The automatic output power ramping matters here as well, because a transmitter that turns on cleanly produces less splatter into the adjacent channel than one that switches abruptly.

Transmit current of 47 mA at plus 14 dBm makes the power amplifier efficiency about 53 percent at that point, and 38 mA at plus 10 dBm makes it about 26 percent. The efficiency falls faster than the power, which is why a battery node that does not need the extra 4 dB should not use it: the current rises by 24 percent for 2.5 times the power, and a link budget that is already closed gains nothing but loses battery life. The plus 16 dBm maximum is a ceiling for the licence conditions, not a target.

Receive current of 26 mA is high for a battery node, and the 1.3 mA idle mode is where the average current is decided. A protocol that wakes for a preamble, listens for a short window and returns to idle spends most of its life at 1.3 mA, and the receive current only applies while the receiver is on. That is why the data rate and the preamble length are power decisions: a 38.4 kbps packet with a 4 byte preamble draws 13.4 mA during the window, and a 1.2 kbps packet with the same preamble draws 2 mA but takes thirty times as long.

The three frequency ranges are not a single wideband front end. Each range has its own matching network and its own crystal frequency in the vendor reference circuit, so a product that has to cover both 434 MHz and 868 MHz needs either two networks or a switched matching section. The frequency resolution also changes with band, 30 Hz per step at 868 MHz and 6 Hz at 169 MHz, which is a consequence of the same reference clock dividing differently, and it matters when a channel plan is being fitted to a regulatory mask.

The 32 pin QFN at 5 mm by 5 mm carries the RF ports, the crystal, the digital interface and the supply decoupling, so the board around it is where the performance is won or lost. A ground plane with vias under the exposed pad, a short path from the matching network to the antenna and a clean supply are the difference between the datasheet selectivity and what a product measures. A 2 layer board can work at 169 MHz and will struggle at 868 MHz, where the loop areas are small enough that a via placement becomes part of the filter.

Where this order code fits

This order code belongs on utility meters, smart grid nodes, alarm and security systems, industrial remote control, wireless sensor networks and telemetry links that have to work in a crowded band at long range. It is chosen when the link budget rather than the data rate is the constraint, because the receiver selectivity and blocking performance are what let a narrow channel survive next to a strong transmitter. Teams comparing it with a neighbouring part start from our RF Component Sourcing page, and teams replacing a part that has gone end of life start from the One Stop RF Supply page.

Questions buyers ask

Which frequency range does one order code cover? The device supports all three ranges, and the band is selected by the matching network and the crystal rather than by a suffix. A 434 MHz product and an 868 MHz product therefore share the same order code and differ in the components around it. That is convenient for a product family and it means the bill of materials, not the part number, records which band a board is built for.

Is 200 kbps enough for metering data? A meter reading is a few dozen bytes, so the link spends its time in access and acknowledgement rather than in payload. At 200 kbps a 64 byte packet takes about 3 ms, which is far below the regulatory dwell time on most channel plans. The practical limit is usually the receiver window and the protocol overhead, not the data rate.

How much range does plus 16 dBm give? Range is set by the link budget, which is transmit power minus receiver sensitivity plus antenna gains minus path loss. This part contributes plus 16 dBm at the top and a saturation point of plus 10 dBm, so the budget is large. In a built up area at 868 MHz the path loss grows quickly with obstructions, and the practical answer comes from a site test, not from a datasheet calculation.

Why is the receive current so much higher than the idle current? The receiver runs a low noise amplifier, a mixer and a synthesiser, and that combination costs 26 mA. Idle mode keeps the crystal and the digital core alive and shuts the RF blocks down, which is what allows a duty cycled protocol to reach a milliamp average. A node that listens continuously cannot be a battery product with this part.

SUPERB supplies this transceiver against the exact order code with the date code and packing stated on the offer, and can hold stock for a metering programme that runs for years. For RF parts that are moving between revisions, the RF Procurement page sets out the checks that keep a link working after the swap.