Contact Us

Rocker and Toggle Switches for Equipment Panels

A panel switch is chosen on the load it breaks and on the cutout already punched in the panel, not on the look of the actuator. Toggle parts on this page run 5 A at 120 V AC on a 6.35 mm round bushing, while snap-in rockers reach 15 A at 125 V AC on a 19.4 x 13 mm cutout. Mains rockers add 128 A inrush for a capacitive supply and a 3 mm contact gap. Every row lists circuit, contact rating, mounting and termination.
quote now

Product Specifications

Product Overview

A panel switch is the one component a customer touches, and it is often chosen last, when the cutout is already punched and the harness is already cut. That order of work explains most of the wrong orders: a 6.35 mm bushing toggle cannot be fitted to a 19.4 x 13 mm rectangular cutout, and a snap-in rocker with 0.187 in quick connect terminals cannot be soldered to a harness that was cut for a PC pin part. The rows on this page carry the cutout, the mounting style and the termination on the same line, so the switch is checked against the panel before it is checked against the circuit.

The rating that matters is the load, not the number on the front of the catalogue. A 5 A 120 V AC toggle rating is a resistive rating. A lamp load draws five to ten times its steady current for the first few milliseconds while the filament heats, and a motor or a solenoid draws a locked rotor current several times its running current. A switch rated 12 A resistive can weld its contacts on a 128 A inrush from a capacitive supply unless the part is rated for that inrush, which is why the DP series rockers in this list carry an 8/128 A figure next to the 12(4) A 250 V AC rating. If the load is inductive or capacitive, the inrush number is the one to compare.

DC is harder on a switch than AC at the same voltage. An AC arc extinguishes at the zero crossing, twice per cycle, while a DC arc has to be stretched and cooled by the switch itself. A contact that is rated 5 A at 120 V AC is typically rated 5 A at 28 V DC or less, and the same body may be rated only 0.5 A at 125 V DC. The rows here give the DC figure separately where the maker publishes it, and the toggle parts show 28 V DC against 120 V AC on the same 5 A contact. A 48 V DC panel needs a part with a DC rating, not an AC part with a DC voltage written beside it.

Mounting is a mechanical decision with an electrical consequence. A bushing toggle passes through a 6.35 mm round hole and is held by a 1/4-40 nut, so the switch can be rotated to any angle and the terminals can be reached from behind the panel. A snap-in rocker is held by two plastic latches and only fits one way, which is fine for a moulded front panel and awkward for a sheet metal one, where the cutout tolerance and the panel thickness both have to be inside the maker window. The DP and R1966 parts are specified for 0.75 to 1.25 mm panel thickness, and a 2 mm panel needs the version with the longer latch rather than force.

Termination decides how the switch is assembled. A solder lug takes a wire directly, which is the cheapest route and the one used on a bench instrument built in low volume. A 0.187 in quick connect takes a crimped receptacle, which is faster on a production line and can be removed for service. A PC thru-hole or right angle terminal mounts the switch on a board rather than a panel, and is used where the switch is part of a front panel assembly that plugs into the main board. The three are not interchangeable, and a quick connect tab that has been soldered to will not hold a receptacle afterwards.

Two mechanical details finish the choice. The actuator marking has to match the panel legend, because an unmarked rocker next to a printed on and off label can be read either way, and a part with an O and I moulded in removes that ambiguity. Sealing matters if the panel is washed or used outdoors: an epoxy sealed toggle keeps flux and wash water out of the contact chamber, while a snap-in rocker without a seal relies on the panel gasket for the same protection. Where the product needs an IP rating, the switch alone does not provide it; the seal is between the actuator and the panel, and it is quoted with the switch.

Key Specifications

ParameterValueApplies to
Contact rating4 A to 15 A at 125 V AC, 2 A to 12 A at 250 V ACPer part number
Mains rating12(4) A 250 V AC on the DP series, 10 A 250 V AC UL and 6 A 250 V AC VDE on the R1966Per part number
Inrush rating8/128 A 250 V ACDP52 and DP62
DC rating5 A at 28 V DC, 4 A at 30 V DC7000 series, M2012
Panel cutout6.35 mm round, 15 x 21 mm, 17.8 x 10.1 mm, 19.4 x 13 mmPer part number
Panel thickness0.75 to 1.25 mm and 1.25 to 2.00 mmDP series, R1966
MountingThreaded bushing 1/4-40, or snap-in latchesPer part number
TerminationSolder lug, 0.187 in quick connect, PC thru-holePer part number
Contact resistance20 mOhm on R1966, 100 mOhm maximum on DPPer series
Insulation resistance100 MOhm minimum, 1000 MOhm minimumDP, R1966
Dielectric strength1500 V AC for one minuteDP, R1966
Electrical life10,000 to 100,000 cycles depending on seriesPer part number
Contact gap3.0 mm minimum, creepage and clearanceDP series
FlammabilityUL94 V-0 on DP, UL94 V-2 on R13-66Per part number
Operating temperature-30 to +65 C on R1966, -30 to +85 C on the 7000 seriesPer part number

Included Models and Order Codes

The rows below are the panel parts we quote most often, in bushing and snap-in form. Ratings are the maker figures for the contact and the load stated in the notes. A dash means the maker does not publish that figure for the part.

Part NumberTypeCircuit and FunctionContact RatingMountingTerminalsNotes
7101SYZQEToggleSPDT, on-none-on5 A at 120 V AC, 5 A at 28 V DC6.35 mm round, 1/4-40 bushingSolder lugEpoxy sealed terminals, 100,000 cycles
7201SYZQEToggleDPDT, on-none-on5 A at 120 V AC and 250 V AC, 5 A at 28 V DC6.35 mm round, 1/4-40 bushingSolder lugEpoxy sealed terminals, 100,000 cycles
7108SYZQEToggleSPDT, on-(on) momentary5 A at 250 V AC, 5 A at 28 V DC6.35 mm round, 1/4-40 bushingSolder lugMomentary action for a jog or reset function
M2012TNW01-DARockerSPDT, on-none-on6 A at 125 V AC, 4 A at 30 V DCSnap-in, 17.8 x 10.1 mm cutoutSolder lug25,000 electrical cycles, 50,000 mechanical
D102J12S215QARockerSPST, on-none-off4 A at 125 V AC, 2 A at 250 V ACSnap-in, panel0.187 in quick connectSilver contacts, 10,000 cycles
DM64J72S205Q6RockerDPST, on-none-off10 A at 125 V ACSnap-in, panel0.187 in quick connectDouble pole for a live and neutral break
DP52J12S215PQRockerSPST, off-none-on12(4) A at 250 V AC, 8/128 A inrushSnap-in, 15 x 21 mm cutout0.187 in quick connect3.0 mm contact gap, 20,000 cycles, UL94 V-0
DP62J12S215PQRockerDPST, off-none-on12(4) A at 250 V AC, 8/128 A inrushSnap-in, 15 x 21 mm cutout0.187 in quick connectSwitches live and neutral together
R1966ABLKBLKFFRockerSPST, on-off15 A at 125 V AC, 10 A at 250 V AC, 6 A at 250 V AC VDESnap-in, 19.4 x 13 mm cutout0.187 in quick connect10,000 cycles, 20 mOhm, -30 to +65 C
R13-66A-02RockerSPST, on-off10 A at 125 V AC, 6 A at 250 V ACSnap-in, 19.4 x 13 mm body0.187 in quick connectUL94 V-2 body, illuminated versions in the same series

Key Features

Cutout and rating on one line – The panel cutout, the mounting style and the contact rating sit on the same row, so a switch is checked against the punched panel before the circuit.

Inrush stated for mains – The DP rockers carry an 8/128 A inrush figure beside the 12(4) A rating, which is the number that decides whether a capacitive supply welds the contacts.

DC rating kept separate – Toggle parts list 28 V DC against 120 V AC on the same contact, because a DC arc does not extinguish at a zero crossing.

Bushing and snap-in both listed – A threaded 1/4-40 bushing for a round hole and snap-in bodies for moulded panels are both here, with the panel thickness range each accepts.

Three termination styles – Solder lug, 0.187 in quick connect and PC thru-hole are named per part, since the harness or the front panel assembly is built around one of them.

Sealing and life figures – Epoxy sealed terminals, cycle counts and the 3.0 mm contact gap on the DP series are listed so a part can be compared on service life rather than price alone.

Applications

These switches cover the front panel of instruments, power supplies, control boxes and test equipment.

Instrument power and standby – A 6.35 mm bushing toggle at 5 A breaks a 120 V AC primary on a bench instrument, and its solder lugs reach a short harness behind a deep front panel.

Power supply mains input – A DPST snap-in rocker at 12(4) A 250 V AC with 128 A inrush breaks live and neutral on a switching supply, where the capacitor bank draws a heavy inrush at every switch on.

Control panel mode selection – A 15 A or 10 A snap-in rocker with an O and I marking selects a mode or a heater zone, and its quick connect tabs take a crimped receptacle for service.

A panel switch is wired to the SUPERB PCB through a harness or a terminal block, and on the SUPERB PCBA builds we supply the switch body, the cutout and the wiring order are checked against the front panel drawing before the harness is cut.

Sourcing and Cross-Reference

Panel switches are cross referenced by cutout first. Two parts with the same rating and the same actuator will not swap if one is a 15 x 21 mm snap-in and the other is a 19.4 x 13 mm snap-in, and the panel is already punched. The second figure is the panel thickness range, because a latch that is right for a 1 mm panel will not hold a 2 mm one. We ask for the cutout drawing or the old part number and quote against the hole, then against the load.

The shortage case is usually an older mains rocker that has gone out of a catalogue. The replacement has to match the cutout, the terminal style and the inrush rating, and the last of the three is the one that gets missed: a 15 A resistive rocker with no inrush figure is not a replacement for a 12(4) A part rated 8/128 A on a supply with a large capacitor bank. Where the original cannot be found, we quote the nearest part with an inrush rating and state the difference, so the change is a decision rather than a surprise.

Terminals and seals are part of the same order. A 0.187 in quick connect switch needs a crimped receptacle of the right width and insulation support, and a panel that is washed needs the sealed version of the same body. Where a customer builds the front panel assembly here, the switches are fitted and operated under load at first article, and the actuator marking is checked against the panel legend before the batch runs.

SUPERB Assembly fits every switch to its cutout on the first article and operates it under load, because a snap-in body that is 0.2 mm too wide will crack a powder coated panel on the second insertion.

Q: Can you supply a panel switch that fits a cutout we already have, with a mains inrush rating for a switching supply?

A: Circuit, load type and panel cutout decide it; the SUPERB Tech desk quotes the switch, the mating terminal and the panel cutout drawing together so the front panel and the wiring agree.

Why Buy Panel Switches Through SUPERB

  1. Cutout checked first: The hole in the panel and the panel thickness are matched before a rating is discussed, so the switch fits the front panel that already exists.
  2. Inrush treated as a rating: Mains parts are quoted with their inrush figure, which is what a switching supply actually presents to the contacts.
  3. DC and AC kept apart: The DC figure is quoted separately, so a 48 V or 125 V DC panel gets a part rated for a DC arc rather than an AC part with a DC label.
  4. Terminals quoted with the switch: The quick connect receptacle or the solder lug is supplied with the switch, so the harness is cut for the terminal that is actually on the part.
  5. Fitted and operated at first article: Switches are fitted to the cutout and worked under load before the batch, which catches a cracked panel or a stiff actuator early.

Related Product Families