Microscope Objectives and Tube Lenses
Product Specifications
Product Overview
An objective is quoted with a magnification, but that number belongs to a system rather than to the lens alone. The magnification is the ratio between the tube lens focal length and the focal length the objective was figured for. Put a 200 mm tube lens behind an objective built for a 180 mm tube and the image is 11 per cent larger than the engraving says, which shifts every measurement taken from a camera image.
The second number that matters is the working distance. A 40X objective with a 0.6 mm working distance is unusable behind a thick window, while a 10X long working distance objective at 34 mm leaves room for a cover slip, a flow cell or a laser nozzle. Numerical aperture and working distance move in opposite directions, so the pair is always read together rather than chosen on magnification.
The third is correction. A plain achromat brings two wavelengths to a common focus and leaves the rest slightly out, which is fine for a monochrome measurement at one wavelength and visible as colour fringing in a colour image. A plan apochromat corrects more, over a flatter field, at a price. For laser focusing the field flatness matters less than the spot, and a plain achromat with the right numerical aperture often does the job.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Magnification | 4X, 10X, 20X, 40X and 60X | Effective value depends on the tube lens |
| Numerical aperture | 0.10 to 0.90 across the family | Resolution improves as NA rises |
| Working distance | 0.6 mm at 40X up to 34 mm at 10X long working distance | Longer distance means lower NA at the same magnification |
| Objective thread | RMS 0.800-36, M25 x 0.75 and W26 x 0.706 | Thread decides which nosepiece and adapter will fit |
| Parfocal length | 45 mm on RMS parts, 95 mm on the W26 long working distance parts | An extender is needed to mix the two |
| Cover glass correction | 0 to 0.17 mm, or a correction collar from 0.11 to 0.23 mm | Metal and machine vision work usually needs none |
| Tube lens focal length | 100, 165, 180 and 200 mm | 200 mm for Thorlabs, Nikon, Leica and Mitutoyo objectives |
| Tube lens working distance | 63.1 mm at 100 mm, 120.6 mm at 165 mm, 133.5 mm at 180 mm, 148.6 to 151.8 mm at 200 mm | Measured from the mounting face |
| Field at the image plane | 15 to 24 mm diameter | Larger field needs a larger tube lens |
| AR coating range | 350 to 700 nm visible, 650 to 1050 nm NIR, 240 to 360 nm UV | Coating follows the application wavelength |
| Housing length | 28.0 to 33.5 mm on the tube lenses | Fits a standard camera port |
| Mounting thread | M38 x 0.5 or SM2 on the tube lenses | Drop in replacement for a microscope port |
Included Models and Order Codes
The first block is objectives in the order a lab buys them: plain achromats at 4X to 40X, then long working distance parts, then plan apochromats. The second block is the tube lenses, where the focal length has to match the objective maker, and the last row is the UV version for 248 to 700 nm.
| Part Number | Type | Magnification | NA | Working Distance | Thread | Notes |
|---|---|---|---|---|---|---|
| RMS4X | Plan achromat | 4X | 0.10 | 18.5 mm | RMS 0.800-36 | Widefield, darkfield capable |
| RMS10X | Plan achromat | 10X | 0.25 | 10.6 mm | RMS 0.800-36 | General imaging objective |
| RMS20X | Plan achromat | 20X | 0.40 | 1.2 mm | RMS 0.800-36 | Short working distance |
| RMS40X | Plan achromat | 40X | 0.65 | 0.6 mm | RMS 0.800-36 | Highest NA of the plain achromats |
| RMS10X-PF | Plan fluorite | 10X | 0.30 | 10 mm | RMS 0.800-36 | Fluorite correction, cover glass 0 to 0.17 mm |
| N10X-PF | Plan fluorite | 10X | 0.30 | 16 mm | M25 x 0.75 | Longer working distance than RMS10X-PF |
| MY10X-803 | Plan apochromat | 10X | 0.28 | 34 mm | M25 x 0.75 | Long working distance, machine vision |
| MY20X-804 | Plan apochromat | 20X | 0.42 | 20 mm | M25 x 0.75 | Long working distance, machine vision |
| TTL100-A | Tube lens | Not applicable | Not applicable | 63.1 mm | SM2 | 100 mm focal length, telecentric |
| TTL165-A | Tube lens | Not applicable | Not applicable | 120.6 mm | SM2 | 165 mm focal length, Zeiss match |
| TTL180-A | Tube lens | Not applicable | Not applicable | 133.5 mm | SM2 | 180 mm focal length, Olympus match |
| TTL200 | Tube lens | Not applicable | Not applicable | 148.6 mm | M38 x 0.5 | 200 mm focal length, visible range |
| TTL200-A | Tube lens | Not applicable | Not applicable | 151.8 mm | SM2 | 200 mm focal length, field 22 mm |
| TTL200-UVB | Tube lens | Not applicable | Not applicable | 176.4 mm | M32 x 0.5 and SM1.5 | 248 to 700 nm, UV imaging |
Key Features
Magnification tied to the tube lens – the focal length the objective was figured for is stated, so a 180 mm part is not used behind a 200 mm tube
Working distance stated – 0.6 mm at 40X and 34 mm at the 10X long working distance part, which decides the fixtures
Thread and parfocal length – RMS 0.800-36 and 45 mm parfocal against W26 and 95 mm, with extenders available
Tube lenses in four focal lengths – 100, 165, 180 and 200 mm, matched to the objective maker rather than to ours
UV option – TTL200-UVB covers 248 to 700 nm where a visible tube lens would absorb the short end
Cover glass correction – 0 to 0.17 mm on the fluorite parts, or a correction collar from 0.11 to 0.23 mm
Applications
Objectives are bought with the camera and the tube lens, because the three form one system and the magnification only holds when they agree.
Instrument imaging ports – a 200 mm tube lens behind a 10X objective on a spectrometer camera port, with the field fixed at 22 mm
Laser focusing – a 20X objective with 0.42 NA to put a spot on a sample, with 20 mm of working distance for the fixture
Machine vision inspection – a long working distance 10X objective over a conveyor, where the 34 mm clearance is the reason for the part
Imaging heads that carry these objectives are built as SUPERB PCB and SUPERB PCBA assemblies when the instrument is produced.
Sourcing and Cross-Reference
Before an objective is quoted, two things are fixed: the tube lens focal length already in the instrument, and the clearance the fixture allows. An objective built for a 200 mm tube behind a 180 mm tube gives 10 per cent more magnification and a smaller field, which is sometimes wanted and usually is not. The clearance decides between a standard part and a long working distance part, and no amount of adjustment makes up for a missing millimetre.
The thread is the second contract. RMS 0.800-36 is the classic microscope thread, M25 x 0.75 is common on newer machine vision objectives, and W26 x 0.706 appears on long working distance parts. Adapters exist for all three, and each one adds length to the stack, which changes the parfocal height and has to be counted.
Where the objective is a replacement for a discontinued part, the useful data is the magnification, the numerical aperture, the working distance and the parfocal length. Four numbers are enough to find an equivalent from another maker, and we quote the original against the alternative rather than leaving the substitution to a catalogue search.
Objective and tube lens pairs for a production instrument are packed through SUPERB Assembly, each part in its own case.
Q: Can you supply a 20X objective with 20 mm working distance and the tube lens that keeps the marked magnification?
A: Yes. SUPERB Tech quotes the objective, the tube lens and the adapter together, and states the magnification that results from the pair.
Why Choose SUPERB for Objectives and Tube Lenses
- Magnification and tube lens paired: the focal length the objective was figured for is on the line, so the marked magnification holds
- Working distance and NA together: both stated, because the two move in opposite directions
- Threads and parfocal height: RMS, M25 and W26 listed with their parfocal lengths and the extenders that bridge them
- Objectives and tube lenses in one quote: so the imaging port is not assembled from two suppliers who never speak
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Lenses and Mirrors for Optical Benches, Optical Filter Mounts and Lens Holders, Polarizers and Waveplates, Photodiode Arrays and Detector Modules, Optical Breadboards and Posts, Obsolete Part Cross Reference.