A fuse holder is the part that decides whether a fuse protects the board or only looks as if it does.\nThe 5 x 20 mm holders here run from 6.3 A at 250 VAC on a snap-in body to 15 A at 500 VAC on a panel part with LCP insulation.\nSMT and THR versions are listed for boards that are reflowed, with a 260 C reflow rating and a matching cover.\nEvery row states the fuse size, the rating and the mounting, because those three have to match the fuse that is fitted.
quote now

Product Specifications

Product Overview

A fuse protects a circuit only if the holder can carry the fault current without heating, and only if the fuse is the one the board was approved with. The holder itself is a simple part: two clips, an insulating body and a way to fix it to the board or the panel. What makes the difference between one holder and another is the contact area of the clips, the material of the body, and whether the part can survive the soldering process the board uses.

The board level parts here are the Keystone 5 x 20 mm range. The 3527 is a snap-in holder with a glass epoxy base and brass tin plated clips, rated 6.3 A at 250 VAC, with an optional 3527C cover that insulates the fuse and keeps it from being touched. The 4527 is the fully insulated version, rated 10 A at 250 VAC, with the fuse accessed from the board edge and a 4527C cover. Both are through hole parts and both are fixed by the clips before the wave, so the holder stays in place while the board is soldered.

The Schurter OGN range covers the reflow side. It is a 5 x 20 mm holder with a thermoplastic body, rated 10 A at 250 VAC, and it comes in THT, THR and SMT versions. The THR version is rated for reflow at 260 C and is packed in blister tape, so it can be placed by the same machine as the rest of the board. The SMT versions are offered with tin plated or gold plated contacts, which is the choice that matters on a board that is washed or coated.

There is also a panel part for the case where the fuse has to be changed without opening the enclosure. The Keystone 3523 is a 5 x 20 mm holder with an LCP body and nickel plated brass clips, rated 15 A at 500 VAC, mounted through a 3.7 mm panel hole. It is the part to use when the fuse is a service item and the board is not accessible.

The rating on the holder is not the rating of the fuse. A 6.3 A holder can carry 6.3 A continuously at the stated temperature, and a 5 A fuse in it will open at its own time current curve, which is what protects the board. The mistake that comes back most often is a 10 A fuse in a 6.3 A holder, which passes the functional test and then heats the holder in a fault. The holder rating and the fuse rating are therefore quoted together, and the row below states both where the maker publishes them.

Key Specifications

ParameterValueApplies to
Fuse size5 x 20 mm cartridgeKeystone 3527, 4527, 3523 and Schurter OGN
Holder rating6.3 A at 250 VACKeystone 3527
Holder rating10 A at 250 VACKeystone 4527 and Schurter OGN
Holder rating15 A at 500 VACKeystone 3523
Body materialGlass epoxy, PBT or LCP, UL94 V-0Per part number
Clip materialBrass, tin plated, or brass, nickel platedPer part number
MountingThrough hole snap-in, or panel mount through a 3.7 mm holePer part number
Reflow rating260 C, THR and SMT versionsSchurter OGN
CoverOptional insulating cover, 3527C and 4527CKeystone snap-in parts
Fuse accessVertical, or from the board edge on the 4527Per part number
Contact resistanceLow contact resistance from the brass clips, stated by the makerAll parts on this page
Operating temperatureUp to 145 C on the blade holderKeystone 3568

Included Models and Order Codes

The rows below are the holders and covers we quote most often. A holder is only half a part, so the cover row is listed separately where the maker sells it on its own. A dash means the maker does not publish that figure.

Part NumberFuse SizeRatingBody and ClipsMountNotes
35275 x 20 mm6.3 A, 250 VACGlass epoxy base, brass tin plated clipsTHT, snap-inLow profile, cover 3527C available
3527CCover only-Nylon, UL94 V-0Fits 3527Insulates the fuse and the clips
45275 x 20 mm10 A, 250 VACPBT body, brass tin plated clipsTHT, board edge accessFully insulated, cover 4527C available
4527CCover only-PBT, UL94 V-0Fits 4527Replacement cover
35235 x 20 mm15 A, 500 VACLCP body, brass nickel plated clipsPanel, 3.7 mm holeFor a fuse changed from outside the case
0031.82015 x 20 mm10 A, 250 VACThermoplastic body, tin plated contactsTHTSchurter OGN open holder
0031.82635 x 20 mm10 A, 250 VACThermoplastic body, tin plated contactsSMT, reflow 260 CBulk, 100 pieces
0031.82735 x 20 mm10 A, 250 VACThermoplastic body, gold plated contactsSMT, reflow 260 CFor washed or coated boards
3-143-0495 x 20 mm10 A, 250 VACThermoplastic body, tin plated contactsTHR, 22.5 mm pin distanceBlister tape, 320 pieces
3568Blade fuse, 11 mm30 A, 500 VACPBT body, brass tin platedTHT, verticalFor automotive blade fuses

Key Features

Holder rating stated – Every row gives the current and voltage the holder itself can carry, which is not the same as the fuse rating and is the number that decides whether the part heats in a fault.

Snap-in fixing before the wave – The 3527 and 4527 clip into the board and stay in place during wave soldering, so the holder does not lift or tilt while the joints are made.

Covers sold separately – The insulating cover is listed as its own part number, so a cover can be replaced without replacing a holder that is already soldered down.

Reflow versions – The THR and SMT parts are rated for 260 C reflow and are packed in tape, so a board that has no wave step can still carry a 5 x 20 mm fuse.

Gold contacts on the SMT part – The gold plated version keeps contact resistance stable on a board that is washed or conformally coated, where a tin surface can film over.

Panel version for service – The 3523 mounts through a panel hole, so a fuse can be changed without opening the enclosure when the fuse is a service item.

Applications

These holders are used wherever a board or an instrument has to be protected against a fault that the supply cannot limit.

Instrument mains input – A 5 x 20 mm holder at the mains entry protects the transformer and the bridge, and the panel version allows the fuse to be changed from the rear panel.

Battery and DC input – A board level holder on a 12 or 24 V input protects the wiring and the connector against a reversed or shorted lead.

Serviceable sub assemblies – A holder with a cover on a plug-in card allows the card to be fused separately, so one fault does not take down the whole rack.

The holder and the fuse are fitted on the SUPERB PCB after the reflow pass, and the SUPERB PCBA route checks that the fuse rating on the line matches the rating printed on the board silkscreen.

Sourcing and Cross-Reference

Fuse holders are approved as part of the safety file, so a replacement is not a simple part swap. The holder rating, the fuse size and the body material all appear on the approval, and a part with a different body material can require a new file even when the rating is the same. We ask for the old part number and the approval reference, and we quote a part with the same body material and rating first.

The second constraint is the soldering process. A THT holder cannot be used on a board that is reflowed on both sides without a wave or a selective solder step, and a THR part is the answer when there is no wave. The pin distance matters too: a 22.5 mm THR part does not fit a pad row laid out for a 20 mm THT part, even though both hold the same fuse.

Fuses themselves are not all the same length. A 5 x 20 mm fuse from one maker can be 20.0 mm and from another 20.6 mm, and a holder with tight end stops will not accept the longer part. When a customer is buying fuses elsewhere, we ask for the fuse part number and check the length against the holder before the order, because a holder that will not close is a line stop.

SUPERB Assembly keeps the holders in their original packaging until the fuse is fitted, because a holder that has been dropped can have a clip that no longer grips the end cap.

Q: Can you supply the holder, the cover and a fuse of the same rating as a matched set, and confirm the holder rating against our fault current?

A: Send the fuse size, the current you have to interrupt and whether the holder sits on the board or on a panel. The SUPERB Tech desk quotes the holder, the cover and the fuse as one set so the ratings cannot be mixed.

Why Buy Fuse Holders Through SUPERB

  1. Holder and fuse quoted as a set: The holder rating and the fuse rating are checked against each other, so a 10 A fuse is not fitted to a 6.3 A holder.
  2. Body material kept for approval: The replacement is matched on body material and rating, which keeps the safety file valid.
  3. Process matched: THT, THR and SMT versions are listed with their reflow rating, so the holder fits the soldering route the board already uses.
  4. Cover available separately: A damaged cover is replaced on its own, without disturbing a holder that is already soldered.
  5. Fuse length checked: The fuse part number is checked against the holder end stops before shipping, which avoids a holder that will not close.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Inline Fuses and Resettable PTC Fuses for Board Protection, Thermal Fuses and Temperature Cutoffs for Battery and Heater Safety, TVS and ESD Protection Diodes for Telecom and Industrial Interfaces, Screw Terminal Blocks and Pluggable Connectors for Field Wiring, Passive Component Cross Reference.