DIP Switches and Rotary Address Switches for Configuration
Product Specifications
Product Overview
A board that has to be set up in the field, or set up once at the end of the line, needs a switch that cannot drift. The two families on this page do that job in different ways. A slide DIP switch gives one independent contact per position, so a 6 position part holds six separate bits, and each bit is set with a small screwdriver through a window in the housing. A rotary coded switch gives one number from 0 to 9 or 0 to F, already encoded in binary on four output pins, so a 16 position part replaces four DIP positions and is read by a small microcontroller without any decoding table.
The slide parts here are the CTS 219 series, which is a surface mount SPST switch with gold plated bifurcated contacts. The contactor is separate from the detent, so the contact does not deflect when the actuator is moved, and the wiping action cleans the contact surface on every change. The series covers 2 to 12 positions, with low profile flush, medium and extended actuators, gull wing or J bend terminals, and an optional top tape seal for boards that are washed after soldering. The body is 6.7 mm deep and the position pitch is 2.54 mm, so the footprint follows the same grid as the rest of the board.
The rotary parts are the Nidec Copal SA-7000 series, a 7.2 mm square surface mount coded switch that is 3.0 mm high. It comes in 10 position real code, 10 position complementary code, 16 position real code and 16 position complementary code, with a minus slot, a cross slot or a moulded knob, and with top setting or side setting. The side setting versions put the adjustment face at the edge of the board, which is the only way to reach a switch that sits under a display or behind a connector. Terminals are J-hook, gull wing or through hole, and the contacts are copper alloy with gold plating.
The choice between the two comes down to how many bits and who sets them. Sixteen separate bits cost sixteen DIP positions and about 41 mm of board length. The same sixteen values fit in one 7.2 mm square rotary part, set by a number printed on the housing, and read back as four lines. On the other hand a DIP switch is easier to read at a glance, easier to change one bit at a time, and cheaper per position. Most instrument boards end up with both: a rotary switch for the address and a small DIP block for the mode and termination.
Two mechanical points decide whether the part works in production. The first is the actuator height. A flush actuator cannot be moved by accident, but it also cannot be moved without a tool, and the tool has to reach it after the board is in the housing. A medium or extended actuator can be set by finger, but it adds height and it can be knocked. The second is the seal. A board that is washed after soldering needs the top tape seal, otherwise the wash water carries flux into the contact chamber and the contact resistance rises after a few months. Both points are stated per part in the table below.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Switch circuit | SPST, 2 to 12 positions | CTS 219 series |
| Contact rating | 100 mA at 20 VDC switching, 100 mA at 50 VDC non-switching | CTS 219 series |
| Contact resistance | 25 mOhm initial, 50 mOhm at end of life | CTS 219 series |
| Insulation resistance | 1000 mOhm minimum between insulated terminals | CTS 219 series |
| Dielectric strength | 500 VAC between adjacent switches for 1 minute | CTS 219 series |
| Actuation life | 2,000 cycles at 100 mA, 20 VDC | CTS 219 series |
| Switch capacitance | 5 pF between adjacent closed switches | CTS 219 series |
| Actuator travel | 0.6 mm | CTS 219 series |
| Reflow and moisture | 250 C for 30 seconds maximum, MSL 1 | CTS 219 series |
| Operating temperature | -55 to +85 C | CTS 219 series |
| Rotary positions and code | 10 or 16 positions, real or complementary code | SA-7000 series |
| Rotary contact rating | 100 mA at 5 VDC switching, 100 mA at 50 VDC non-switching | SA-7000 series |
| Rotary body | 7.2 mm square, 3.0 mm low profile, PPS housing | SA-7000 series |
| Rotary terminals | J-hook, gull wing or through hole pins | SA-7000 series |
| Rotary contact material | Copper alloy, gold plated slider and fixed contact | SA-7000 series |
| Packing | Anti-static tube, tape and reel, or 500 piece reel on the rotary parts | Per part number |
Included Models and Order Codes
The rows below are the positions and code types we quote most often. The rating column follows the maker rating of each family, so the 100 mA at 20 VDC of a slide switch is not the same test as the 100 mA at 5 VDC switching rating of a rotary part. A dash means the maker does not publish that figure.
| Part Number | Positions and Code | Terminal and Mount | Actuator or Setting | Rating | Notes |
|---|---|---|---|---|---|
| 219-2LPSJF | 2, SPST | SMD, J bend | Low profile flush | 100 mA, 20 VDC | Gold contacts, tape and reel option |
| 219-3MSTR | 3, SPST | SMD, gull wing | Medium height | 100 mA, 20 VDC | Auto placeable, tape and reel |
| 219-6LPST | 6, SPST | SMD, gull wing | Low profile flush, top tape seal | 100 mA, 20 VDC | Sealed for board washing |
| 219-10LPSTRF | 10, SPST | SMD, gull wing | Low profile flush | 100 mA, 20 VDC | Ships in the OFF position, tape and reel |
| SA-7010TB | 10, real code (BCD) | SMD, gull wing | Top setting, minus slot | 100 mA, 5 VDC | Taping, 500 pieces per reel |
| SA-7030TB | 10, complementary code | SMD, gull wing | Top setting, minus slot | 100 mA, 5 VDC | Outputs read inverted, for active low logic |
| SA-7050TB | 16, real code (hex) | SMD, gull wing | Top setting, minus slot | 100 mA, 5 VDC | Address 0 to F on four lines |
| SA-7110TB | 10, real code | SMD, gull wing | Top setting, with knob | 100 mA, 5 VDC | Set by hand without a tool |
| SA-7210TB | 10, real code | SMD, gull wing | Top setting, cross slot | 100 mA, 5 VDC | Cross slot for a Phillips driver |
| SA-7012TB | 10, real code | SMD, gull wing | Low profile side setting | 100 mA, 5 VDC | 3.0 mm high, reel only |
Key Features
Gold on both contact faces – The slide types use bifurcated gold plated contacts, and the rotary types use a gold plated slider against a gold plated fixed contact, so a low current signal does not depend on a tinned surface.
Detent separate from the contactor – On the 219 series the contactor does not deflect when the actuator moves, which keeps the contact force stable over the 2,000 cycle life instead of fading with each operation.
Flush, medium and extended actuators – The same footprint is offered with three actuator heights, so the switch can be set by tool on a sealed board or by finger on a panel that is opened for service.
Top tape seal for washing – The optional top tape keeps wash water and flux out of the contact chamber, which is the difference between a stable contact resistance and a part that drifts after cleaning.
Encoded output on the rotary parts – A 16 position rotary part puts a full hex address on four lines, replacing four DIP positions and the decoding that goes with them.
Side setting for hidden boards – The low profile side setting version brings the adjustment face to the board edge, so a switch under a display or behind a connector can still be changed after assembly.
Applications
These switches are used wherever a board has to hold a setting that is not written in firmware.
Bus address and device ID – A 16 position rotary switch sets the address of a board on a shared RS-485 or CAN bus, so eight identical boards can sit on one line without a programming step.
Mode and range selection – A 4 or 6 position DIP block selects a measurement range, a filter setting or a test mode that has to be visible on the bench and changeable without a laptop.
Termination and bias – A 2 position DIP switch connects or removes a bus termination resistor and a bias network, which is the usual way to make one board work at both ends of a line.
Both switch types are placed on the SUPERB PCB in the same pass as the logic they configure, and the SUPERB PCBA run checks the start position of every switch against the build sheet before the board leaves the line.
Sourcing and Cross-Reference
These parts are usually bought late, after the board is laid out, and the constraint is the footprint. A 2.54 mm pitch DIP switch has a fixed pad row, and the actuator height is set by the gap between the board and the housing. When a specific part goes short, the first question is whether the same series is available in another actuator height or another terminal style, because those share the pad row. We ask for the old part number and the pad drawing, then quote the nearest part in the same family rather than a part from another maker with a different body.
The rotary parts are easier to replace, because the 7.2 mm square body and the 2.54 mm terminal spacing are common across the coded switch families. What is not common is the code. A 10 position real code part and a 10 position complementary code part look the same and read opposite, and a board that expects one will read the other as an invalid address. The code type is therefore the first field we confirm, before the terminal style or the colour.
Ageing stock is the other risk. A switch that has been in a warehouse for years can have a dull gold surface and a detent that feels loose, and neither shows up until the board is in test. We ask for the date code and the packing, and we do not break a sealed reel for a sample, because the seal is what keeps the contacts clean. Where a part is no longer in the catalogue, a sealed reel from the last production run is usually a better answer than a substitute with a different footprint.
SUPERB Assembly keeps the taped reels sealed until the placement program is running, because a reel that has been opened early picks up dust on the gold contacts and the detent starts to feel different.
Q: Can you supply a 16 position rotary address switch and the matching DIP block on the same order, with the code type confirmed before shipping?
A: Tell us the number of positions, the code you need on the outputs and the height left above the board. The SUPERB Tech desk quotes the switch and the matching tape seal so the part arrives ready for the wash step.
Why Buy Configuration Switches Through SUPERB
- Code type confirmed first: Real and complementary code parts are physically identical, so the code type is checked against the old part number before anything is quoted.
- Footprint matched to the pads: The old part number or the pad drawing decides the quote, which keeps a replacement on the row that already exists on the board.
- Seal and actuator stated per part: Every row gives the actuator height and whether the part carries a top tape seal, so the wash step and the housing gap are known before the order.
- Both families in one order: The rotary address switch and the small DIP block are quoted together, which removes the mismatch between an address set in hex and a mode set in bits.
- Placed and checked in the build: The switches are placed in the same pass as the logic, and the start position of every switch is checked against the build sheet at first article.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Pin Headers and Female Sockets for 2.54 mm Board Stacking, Tactile and Slide Switches for Front Panel Control, Rocker and Toggle Switches for Equipment Panels, Trimmer Potentiometers for Calibration and Bias Setting, Passive Component Cross Reference.