D-Sub Connectors for Serial and Instrument Ports
Product Specifications
Product Overview
The D-Sub is still the connector on a service port, an instrument I/O and a legacy panel loom, and it survives because the shell does two things that a rectangular connector does not. The trapezoid shape only mates one way round, so a port cannot be plugged in backwards, and the metal shell surrounds the contacts, so a shielded cable can be bonded to the chassis at the connector rather than at the board.
The NorComp 171 series is the solder cup body we quote most often. It is a standard density part in five shell sizes, 9, 15, 25, 37 and 50 positions, with stamped non-removable contacts. The rating is 5 A per contact at 250 V AC working and 500 V AC for one minute, the contact resistance is 15 mOhm maximum, the insulation resistance is 1,000 MOhm minimum, and the working range is -50 to +100 C. The shell is nickel plated steel, the insulator is glass filled thermoplastic to UL94 V-0, and the contacts take 20 to 28 AWG wire.
The TE AMPLIMITE HD-20 5747840-3 is the board mount part. It is a 9 position plug in shell size 1 on a 2.74 mm centreline, right angle, with a front metal shell, board locks, a ground strap and grounding indents, rated 125 V. The insulator is a 94V-0 thermoplastic and the contacts are posted, so the part is soldered into the board and the mating half comes in from the panel. That is the shape used when the port is on the back of an instrument and the board is fixed to the chassis behind it.
The mistake that costs the most time on a D-Sub order is the shell size. A 9 position plug is shell DE and a 15 position plug is shell DA, and the two shells are different widths, so a DE plug cannot be forced into a DA receptacle no matter how the contacts line up. Where a port is being changed from 9 to 15 positions, the panel cutout, the mating harness and the jack screw spacing all change with the shell, and the connector is the smallest part of that change.
Hardware is the second point. A solder cup body on a cable needs a backshell and a strain relief, and a board mount body on a panel needs either a threaded insert for a jack screw or a board lock that holds it to the board. Without one of the two, a connector that is plugged and unplugged walks out of the panel, and the contacts that were aligned at build are no longer aligned a month later. The order codes on this page are stated with their hardware so that a part is not quoted bare when the panel expects a screw.
Termination is the third. A solder cup body is right for a cable harness that is made by hand, a posted right angle body is right for a board edge, and a crimp body is right where the harness is made on a machine and the contacts are inserted after the wire is crimped. The three are not interchangeable on a drawing, and a solder cup part quoted against a crimp requirement is a part that will be returned.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Shell sizes | DE 9, DA 15, DB 25, DC 37, DD 50 positions | Both families |
| Contact spacing | 2.76 mm horizontal, 2.84 mm between rows | Standard density bodies |
| Board mount centreline | 2.74 mm | TE HD-20 5747840-3 |
| Current per contact | 5 A | NorComp 171 series |
| Working voltage | 250 V AC, 125 V | NorComp 171, TE HD-20 |
| Dielectric withstanding | 500 V AC for one minute | NorComp 171 series |
| Contact resistance | 15 mOhm maximum | NorComp 171 series |
| Insulation resistance | 1,000 MOhm minimum | NorComp 171 series |
| Wire size | 20 to 28 AWG | NorComp 171 solder cup |
| Shell material | Nickel plated steel, tin plated steel | NorComp 171, TE HD-20 |
| Insulator | Glass filled thermoplastic, UL94 V-0 | Both families |
| Contact plating | Gold flash, gold over nickel | NorComp 171, TE HD-20 |
| Operating range | -50 to +100 C | NorComp 171 series |
| Hardware | Board lock, ground strap, grounding indents, 4-40 inserts | By order code |
Included Models and Order Codes
The rows below are the D-Sub bodies we quote most often. Shell size and termination are given per part because those two decide whether the port fits the panel, and a dash means the maker does not publish that figure.
| Part Number | Shell | Positions | Termination | Rating | Hardware | Notes |
|---|---|---|---|---|---|---|
| 171-009-103L001 | DE | 9 plug | Solder cup | 5 A, 250 V AC | - | Gold flash, 20 to 28 AWG, nickel shell |
| 171-009-203L001 | DE | 9 receptacle | Solder cup | 5 A, 250 V AC | - | Mating half for the 9 position plug |
| 171-015-103L001 | DA | 15 plug | Solder cup | 5 A, 250 V AC | - | Gold flash, wider shell than the DE |
| 171-025-103L001 | DB | 25 plug | Solder cup | 5 A, 250 V AC | - | Gold flash, 25 position body |
| 171-037-103L001 | DC | 37 plug | Solder cup | 5 A, 250 V AC | - | Gold flash, 37 position body |
| 5747840-3 | DE | 9 plug | Right angle posted, through hole | 125 V | Board lock, ground strap | 2.74 mm centreline, front metal shell |
Key Features
Shell size stated with every part – The 9, 15, 25, 37 and 50 position bodies are listed with their shell letter, because the shell and not the pin count sets the panel cutout.
Solder cup and board mount – A cable harness and a board edge port are both on this page, so a port is not built on the wrong termination because only one was quoted.
Hardware listed per code – Board locks, ground straps and grounding indents are given per order code, so a panel port is not supplied as a bare body.
Metal shell for shield bonding – A nickel or tin plated steel shell is what lets a shielded cable be bonded at the connector rather than at the board.
Wire range given – The 20 to 28 AWG range is the figure the crimp or the solder joint is checked against when a loom is made off by hand.
Contact resistance and withstanding – 15 mOhm and 500 V AC for one minute are published per family, so a service port is not specified on a datasheet guess.
Applications
These connectors are used where a port has to be keyed, shielded and mechanically strong enough to survive a cable being pushed in by feel.
Instrument service ports – A 9 position right angle plug on the back panel takes a serial cable, with the board locks holding the body while the cable is pushed home.
Industrial control panels – A 25 position solder cup body on a panel loom carries control signals into a cabinet, with the metal shell bonded to the panel at the connector.
Test and measurement racks – A 15 position body on a rack module gives a keyed interface that cannot be plugged in backwards above a live supply rail.
The shell of a D-Sub is wider than the contacts, so the panel cutout on a SUPERB PCB build is set from the shell size rather than from the pin count. On the SUPERB PCBA route the connector is placed before the tall parts beside it, because the shell has to be reachable with a screwdriver after the board is fixed to the chassis.
Sourcing and Cross-Reference
A D-Sub is bought by shell size and approved by termination. When a port is replaced, the first question is the shell letter on the old part, because a 9 position and a 15 position body are different widths and the panel cutout follows the shell. The second question is whether the cable is made off by hand or on a machine, because a solder cup body and a crimp body are not interchangeable on a drawing.
The second point is the hardware. A board mount body without a board lock or a threaded insert is held by its solder tails alone, which is fine on a bench unit and wrong on a panel that is plugged weekly. Where the panel is thin, the jack screw and the threaded insert take the load, and the connector stays square. We quote the hardware with the body rather than after the fact, because a bare body that has to be retrofitted usually means the panel is already drilled.
The third point is the plating and the shell. A gold flash is enough for a port that is plugged a few dozen times over its life, and a thicker gold over nickel is used where the port is used daily. A nickel plated steel shell is the shield, and a plastic shell with a metalised coating is a different part with a different bonding path. On an instrument that has to pass an EMC test, that difference is the one that decides whether the port is a leak.
SUPERB Assembly fits the jack screws and checks the shell height against the panel before the harness is made off, because a shell that sits proud by a millimetre will not let the mating half latch.
Q: Can you supply a 9 position D-Sub plug in shell DE with a right angle board mount and board locks, and confirm the shell width for our panel cutout?
A: Send the position count, whether the port is on a cable or on a board, and the hardware the panel needs. The SUPERB Tech desk quotes the shell size with the connector, because a 9 position plug and a 15 position receptacle are different shells and do not mate.
Why Buy D-Sub Connectors Through SUPERB
- Shell size confirmed first: The order is built from the shell letter rather than the pin count, which is where a port fails to mate.
- Termination matched to the harness: Solder cup, posted right angle and crimp bodies are kept apart, so a hand made loom is not quoted a crimp part.
- Hardware supplied with the body: Board locks and threaded inserts are part of the order, so a panel port is not left held by its solder tails alone.
- Plating stated: Gold flash and thicker gold over nickel are given per part, so a daily used port is not built on a thin finish.
- Shell kept square at assembly: The shell height is checked against the panel before the harness is made off, because a shell that sits proud will not latch.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: DIN and Circular Connectors for Panel Wiring, Cable Glands and Strain Relief Bushings for Enclosure Entries, Wire to Board Crimp Housings and Headers for Harness Builds, Screw Terminal Blocks and Pluggable Connectors for Field Wiring, Obsolete Part Cross Reference Hub.