Hall Effect Current Sensors for Motor and Supply Monitoring
Product Specifications
Product Overview
A motor drive, a battery charger or a power supply needs to know the current in a conductor without touching it. A shunt and an amplifier works, but the shunt sits in the current path and the amplifier has to survive the common mode of that path. A Hall effect sensor puts the conductor inside the package, measures the field it produces and returns a voltage referred to its own ground, so the control side stays isolated from the power side by the package itself.
The integrated conductor is what separates the parts on this page from a bare Hall element. The ACS712 carries 1.2 milliohms of conductor and returns 185 mV per amp on the 5 A version, 100 mV per amp on the 20 A version and 66 mV per amp on the 30 A version, with 80 kHz of bandwidth and 2.1 kVRMS of isolation in a SOIC-8. The ACS758 raises the range to 50 A, 100 A and 150 A with a 100 microohm conductor, 120 kHz of bandwidth and 3 V to 5.5 V operation, and it is the part quoted for inverter legs and battery disconnect switches.
Above 100 kHz the choice moves to the newer die. The ACS37002 reaches 400 kHz with 5 kVRMS of isolation in a SOICW-16, the MLX91220 covers dc to 300 kHz with a 2 microsecond response and 0.9 milliohms of conductor, and the TMCS1100 holds total error to 0.4 percent typical with an external reference pin so that the zero current level can be set by the ADC rather than by a divider. Where the conductor is a busbar rather than a trace, the LEM HO 25-P is a through hole module with an 8 mm by 8 mm aperture, 250 kHz of bandwidth and overcurrent detection at 2.63 times the nominal current.
Key Specifications
| Parameter | SOIC integrated conductor | Module and wide body |
|---|---|---|
| Current range | Plus or minus 5 A to plus or minus 150 A depending on part | 25 A nominal, 62.5 A measuring range on HO 25-P |
| Sensitivity | 66 mV/A, 100 mV/A, 185 mV/A, 400 mV/A | 32 mV/A at 5 V on HO 25-P; 26.7 mV/A to 120 mV/A on MLX91220 SOIC-16 |
| Bandwidth | 80 kHz on ACS712, 120 kHz on ACS758, 300 kHz on MLX91220, 400 kHz on ACS37002 | 250 kHz on HO 25-P |
| Isolation | 2.1 kVRMS on ACS712, 2.4 kVRMS on MLX91220 SOIC-8, 3 kVRMS on TMCS1100, 5 kVRMS on ACS37002 | 4.8 kVRMS on MLX91220 SOIC-16, 4300 V insulated test on HO 25-P |
| Conductor resistance | 100 microohm on ACS758, 1.2 milliohm on ACS712, 0.9 milliohm on MLX91220 SOIC-8 | Through hole aperture, primary conductor supplied by the user |
| Output | Ratiometric or fixed voltage, 0.5 V to 4.5 V around the quiescent level | Voltage output around 2.5 V reference on HO 25-P |
| Supply voltage | 3 V to 5.5 V | 5 V plus or minus 10 percent on HO 25-P |
| Response time | 2 microseconds on MLX91220 | 3.5 microseconds to 90 percent on HO 25-P |
| Package | SOIC-8, SOICW-16, SOIC-16 wide body | Through hole module with 8 mm by 8 mm aperture |
Included Models and Order Codes
The table lists the codes quoted for servo drives, chargers, inverters and power distribution boards. State the peak current, the supply rail, the isolation class the end product needs and the bandwidth of the control loop, and the part and the sensitivity option are confirmed.
| Part Number | Current Range | Sensitivity | Bandwidth | Package |
|---|---|---|---|---|
| ACS712ELCTR-05B-T | Plus or minus 5 A | 185 mV/A | 80 kHz | SOIC-8 |
| ACS712ELCTR-20A-T | Plus or minus 20 A | 100 mV/A | 80 kHz | SOIC-8 |
| ACS712ELCTR-30A-T | Plus or minus 30 A | 66 mV/A | 80 kHz | SOIC-8 |
| ACS758LCB-050U-PFF-T | 50 A unidirectional | 60 mV/A | 120 kHz | PFF module |
| ACS758LCB-100B-PFF-T | Plus or minus 100 A | 20 mV/A | 120 kHz | PFF module |
| TMCS1100A1QDR | Plus or minus 29 A | 50 mV/A | 80 kHz | SOIC-8 |
| TMCS1100A2QDR | Plus or minus 14.5 A | 100 mV/A | 80 kHz | SOIC-8 |
| MLX91220KDC-ABF-050-RE | Plus or minus 50 A | 40 mV/A fixed | 300 kHz | SOIC-8 |
| MLX91220KDF-ABF-075-RE | Plus or minus 75 A | 26.7 mV/A fixed | 300 kHz | SOIC-16 |
| HO 25-P | 25 A nominal, 62.5 A range | 32 mV/A | 250 kHz | Through hole module |
Key Features
Isolation inside the package – the current path and the signal pins are separated by the package body, from 2.1 kVRMS on the SOIC-8 parts to 5 kVRMS on the ACS37002, so no optocoupler is needed on the measurement line.
Conductor loss kept low – 100 microohms on the ACS758 and 0.9 milliohms on the MLX91220 mean a 100 A leg dissipates about 1 W in the sensor instead of the several watts a shunt of the same range would take.
Bandwidth to 400 kHz – the ACS37002 and the MLX91220 see the edge of a 20 kHz switching cycle, which is what a current loop needs to act inside one PWM period rather than one cycle late.
Fixed or ratiometric output – a fixed output part keeps the sensitivity independent of the supply, and a ratiometric part tracks the ADC reference, so the choice follows the converter rather than the sensor.
Overcurrent detection on board – the MLX91220 SOIC-16 and the HO 25-P both carry a comparator output near 2.6 to 3.2 times the nominal current, which can trip a gate driver without a software round trip.
Error budget stated per grade – total error of 0.4 percent typical on the TMCS1100 and 1.5 percent on the ACS712 are quoted with the temperature range they apply to, so the loop gain is set on real numbers.
Applications
These sensors are quoted for equipment that has to measure a current in a power path, typically where: A current sensor is quoted with the SUPERB PCB and the SUPERB PCBA build for the same drive board, so the isolation gap and the conductor width are checked against the sensor that will be fitted.
Servo and pump drives – a three phase inverter needs one sensor per leg with enough bandwidth to close the current loop inside the PWM period, which puts the ACS37002 and the MLX91220 at the top of the list.
Battery chargers and disconnect units – a charger has to measure charge and discharge separately and detect a short, and the 100 A ACS758 or the HO 25-P module covers the pack side where the conductor is a busbar.
Power supplies and UPS modules – a power factor stage needs an average current signal with low offset drift, and the fixed output TMCS1100 keeps the reading stable when the 5 V rail moves.
Sourcing and Cross-Reference
Two sensors with the same range can differ in the conductor resistance, the isolation rating, the quiescent level and whether the output is ratiometric. A replacement that changes the quiescent level shifts every reading by a constant, and one that changes the ratiometric behaviour drifts with the supply, so the cross reference is checked against the ADC reference and the firmware scaling, not only against the footprint. We quote the range, the sensitivity, the isolation class, the bandwidth and the package on every line.
Where a part is being replaced for isolation or accuracy reasons, the new sensor usually needs a different creepage gap on the board. The 8 mm aperture module and the SOICW-16 part both take more space than a SOIC-8, so the mechanical change is quoted together with the electrical one and the layout change is reviewed before the first batch.
SUPERB Assembly support covers the reflow of the SOIC-8 and SOICW-16 parts and the through hole module, including the creepage check after cleaning.
Q: Can you supply a Hall sensor that keeps the same output scaling as the part on our board?
A: Yes. Send the current range, the supply rail, the output scaling and the isolation class, and the SUPERB Tech sales team will confirm the order code and the nearest part with the same quiescent level.
Why Buyers Source Hall Effect Current Sensors Through SUPERB
- Isolation class on the quote: the working voltage and the test voltage are stated per line, which is what a safety review asks for first.
- Scaling matched to the ADC: sensitivity and quiescent level are quoted together, so the firmware scaling does not have to be recalculated for a replacement.
- Power path parts in one place: the sensor, the shunt and the gate driver for the same leg are quoted as one set, which keeps the thermal budget in one number.
- Long lifecycle supply: parts a drive was qualified around are held with date codes while an alternative is tested on the bench.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Sensors and detectors, Current sense amplifiers and shunt monitors, Motor driver ICs, Gate driver chips, Pin to pin cross reference.