Contact Us
  • Home
  • COMPONENTS
  • Common Mode Chokes and Power Inductors for Supply Filtering

Common Mode Chokes and Power Inductors for Supply Filtering

Two line common mode chokes in 0805, 1206 and 1210 sizes, 90 ohm to 2.2 kohm at 100 MHz. Rated current from 200 mA to 1 A with DCR from 0.19 ohm to 0.9 ohm. Shielded power inductors from 1 uH to 33 uH for buck and boost stages. Automotive grade and commercial grade options with reel packing.
quote now

Product Specifications

Product Overview

A switching supply radiates through two paths, and the parts that close them are different. Differential noise, the ripple that flows out on one conductor and back on the other, is handled by the inductor and the output capacitors. Common mode noise, which flows out on both conductors in the same direction and returns through the chassis, is handled by a common mode choke: two windings on one core, phased so that the differential current cancels its flux and the common mode current sees the full impedance. That is why a choke is specified by impedance at 100 MHz rather than by inductance alone, and why its rated current is set by the differential current it carries rather than by the noise it blocks.

The chokes on this page are the two line signal and power entry parts. The TDK ACM2012 series puts 90 ohm or 120 ohm of common mode impedance at 100 MHz in a 2.0 by 1.2 mm body, with rated current of 400 mA and 370 mA and DC resistance of 0.19 ohm and 0.22 ohm, which is the usual choice on a USB pair, a CAN pair or an RS-485 pair that leaves the board. The Wurth WE-CNSW 744232090 is an AEC-Q200 qualified 1206 part at 370 mA with 0.3 ohm maximum, used on automotive CAN and sensor harnesses where the qualification matters as much as the impedance.

The second half of the page is the power inductor range, which is a different selection problem. A buck stage chooses inductance from the ripple current it will accept, then checks that the saturation current at the peak is above the worst case load and that the DC resistance does not eat the efficiency the converter was chosen for. Shielded construction matters on a dense board because an unshielded drum radiates into the traces beside it. The Coilcraft XAL, TDK SPM, Vishay IHLP and Bourns SRR families here cover 1 uH to 33 uH from a 4 mm to a 12.5 mm footprint, which spans a 0.5 A point of load converter up to a 10 A intermediate rail.

Key Specifications

ParameterSignal line chokesPower entry chokes
Impedance90 ohm and 120 ohm at 100 MHz, 65 ohm and 90 ohm minimum300 ohm to 2.2 kohm at 100 MHz on the larger bodies
Rated current370 mA to 400 mA500 mA to 1 A depending on impedance
DC resistance0.19 ohm to 0.22 ohm maximum0.3 ohm to 0.9 ohm maximum
Rated voltage50 V50 V to 125 V
Common mode inductanceAround 0.11 uH typical on the 90 ohm partHigher turns count, higher impedance
ConstructionMultilayer or wire wound, two lines on one coreWire wound on a ferrite core, two or four lines
QualificationCommercial and AEC-Q200 versionsCommercial and AEC-Q200 versions
Package0805 and 1206 size, 2.0 by 1.2 mm and 3.2 by 1.6 mm1206, 1210 and larger

Included Models and Order Codes

The table lists the two line chokes most often quoted for interface and power entry filtering. State the impedance at 100 MHz, the differential current the line carries, the voltage the barrier sees and whether automotive qualification is needed, and the order code is confirmed with packing.

Part NumberTypeImpedance at 100 MHzRated CurrentDC ResistanceSize
ACM2012-900-2P-T002Two line common mode choke, signal90 ohm typical, 65 ohm minimum400 mA0.19 ohm maximum2.0 by 1.2 by 1.3 mm
ACM2012-121-2P-T002Two line common mode choke, signal120 ohm typical, 90 ohm minimum370 mA0.22 ohm maximum2.0 by 1.2 by 1.3 mm
ACM2012-361-2P-T002Two line common mode choke, signal360 ohm typical300 mA0.35 ohm maximum2.0 by 1.2 by 1.3 mm
744232090Two line common mode choke, AEC-Q20090 ohm at 100 MHz, 0.111 uH typical370 mA at 40 K rise0.3 ohm maximum1206
744232222Two line common mode choke, AEC-Q2002.2 kohm at 100 MHz200 mA0.9 ohm maximum1206

Shielded Power Inductors for Buck and Boost Stages

The second table is the inductor side of the same filter, where the selection is set by ripple current, saturation and DCR rather than by impedance. Inductance and case size are fixed by the part number; rated current and DCR are stated on the datasheet for the exact suffix.

Part NumberInductanceCase SizeConstructionTypical Stage
XAL4020-102MEB1.0 uH4.0 by 4.4 mmShielded compositePoint of load buck at 3 to 5 A
XAL5030-222MEB2.2 uH5.3 by 5.5 mmShielded compositePoint of load buck at 5 to 8 A
XAL6060-333MEB33 uH6.6 by 6.4 mmShielded compositeSEPIC and boost stages
SPM6530T-4R7M4.7 uH6.5 by 6.0 mmShielded metal alloy12 V to 5 V buck at 3 A
SPM4012T-2R2M2.2 uH4.0 by 4.0 mmShielded metal alloyLow profile point of load
IHLP2525CZER100M0110 uH6.9 by 6.5 mmShielded composite24 V to 12 V intermediate rail
SRR1260-100M10 uH12.5 by 12.5 mmShielded drumHigher current intermediate bus
SRR6045-220M22 uH6.0 by 6.0 mmShielded drumBoost and input filter stages

Key Features

Impedance stated at 100 MHz – the datasheet number is impedance at the frequency where the noise actually sits, with minimum and typical values separated, so the filter can be judged at the corner rather than at DC.

Differential current rating – the rated current is the current the windings carry without saturating, which is what decides whether a choke can sit on a 500 mA USB rail.

Low profile bodies – 1.3 mm and 1.6 mm heights keep the choke under a shield can and on the same side as the connector.

Automotive qualification – AEC-Q200 versions of the same impedance are available where the harness is inside a vehicle and the qualification has to be on the drawing.

Shielded power inductors – composite and metal alloy shields keep the field inside the part, which matters when a sensitive analogue trace runs within a few millimetres.

Reel and cut tape – full reels for production and cut tape for prototype, from the same order code family, so the first build and the volume build use the same part.

Applications

These parts are quoted for interface and supply filtering, typically where: A filter section is normally quoted with the SUPERB PCB and SUPERB PCBA work we support for the same board, so the chokes, the inductors and the assembly come from one source.

USB, CAN and RS-485 ports – a two line choke at the connector removes the common mode current that would otherwise leave the board on the cable and fail a radiated emissions scan.

DC input and power entry – a higher impedance choke in front of the regulator keeps switching noise off the input harness and improves conducted emissions at the low frequency end.

Point of load converters – a shielded 1 uH to 10 uH inductor sets the ripple and the transient response of a buck stage, with DCR and saturation chosen against the load step.

Sourcing and Cross-Reference

Passive parts are where a BOM is most often substituted without notice, and where the substitution is most often invisible until an emissions test fails. A 90 ohm choke and a 120 ohm choke look the same on a reel, and a 0.19 ohm DCR part and a 0.35 ohm part have the same body. We quote the full order code with the impedance, the current rating and the size on the confirmation, and where a substitute is proposed the impedance curve and the DCR are stated side by side.

The other practical point is packing. Chokes and inductors are quoted per reel, and a partial reel from a different lot changes the DC resistance and sometimes the impedance by a few percent. For a product that has already passed emissions, mixing lots inside one build is the usual cause of a marginal result, so we keep the lot together where the quantity allows and record it on the delivery note.

For volume builds, SUPERB Assembly support covers the SMT assembly of the supply and interface sections.

Q: Can you supply the choke and the power inductor for one board from the same lot?

A: Yes. Send the complete order code with the impedance, the current rating and the reel size, and the SUPERB Tech sales team will confirm availability and the lot on hand.

Why Buyers Source Magnetics Through SUPERB

  1. Impedance and DCR on the quote: the two numbers that decide whether a choke works are stated per line, not left to the family name.
  2. Automotive and commercial in one place: AEC-Q200 and commercial versions of the same impedance are quoted together, so the qualified part is not a separate purchase order.
  3. Lot control: date code and lot are recorded per reel, which matters on a product that has already passed an emissions test.
  4. Inductor and capacitor together: the magnetics, the output capacitors and the converter for one rail are quoted as a set, so the ripple calculation uses the parts that will actually be fitted.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Passive components, Step down DC-DC converters, TVS and ESD protection diodes, BOM shortage recovery, How to reduce component cost.