Single and dual port LAN magnetics for 10/100BASE-TX and 1000BASE-T. 1:1 turns ratio modules with 350 microhenry of open circuit inductance. 1500 Vrms hipot and common mode rejection from 43 dB at 30 MHz. PoE variants rated for four pair power up to 30 W at the module.
quote now

Product Specifications

Product Overview

An Ethernet magnetics module does three jobs at once: it couples the differential pair to the PHY, it blocks the DC and the low frequency common mode that would otherwise travel down the cable, and it provides the isolation barrier that a 1500 V hipot test checks. A port that works on the bench and fails EMC usually fails on the common mode choke or on the centre tap bypass, not on the transformer ratio.

The 10/100 group is still the volume part in industrial and building equipment. The H1102NL and the HX1188NL are single port 1:1 modules with 350 microhenry of inductance, 1.1 and 1.0 dB of insertion loss over 100 kHz to 100 MHz, 20 dB of return loss at 30 MHz, 42 dB of common mode rejection and 1500 Vrms of isolation, in a 12.7 by 7.1 mm surface mount module. The HX1188NL is the extended temperature version, rated from -40 to 85 C, and the H1199NL trades a little common mode rejection for 0.9 dB of insertion loss, which is the part used where the cable run is short.

The gigabit group adds a choke and a tighter return loss because 1000BASE-T uses all four pairs in both directions. The H5008NL and the HX5008NL are single port 1:1 modules with 1.0 dB maximum insertion loss over 1 to 100 MHz, 18 dB of return loss at 30 MHz and 43 dB of common mode rejection, and the HX5008NL is rated for four pair PoE at 30 W with an extended temperature range. The H5012NL and the H5014NL put two ports in one package with 1.4 dB maximum insertion loss, which is what a small industrial switch or a gateway with two copper ports needs.

Key Specifications

Parameter10/100BASE-TX modules1000BASE-T modules
Speed10/100BASE-TX1000BASE-T, four pair
Turns ratio1:1 on transmit and receive1:1, for 1:1 transceivers
Inductance350 microhenry325 to 350 microhenry
Insertion loss0.9 to 1.1 dB maximum, 100 kHz to 100 MHz1.0 dB maximum, 1 to 100 MHz
Return loss20 dB at 30 MHz18 dB at 30 MHz
Common mode rejection42 dB at 30 MHz43 dB at 30 MHz
Isolation1500 Vrms hipot1500 Vrms hipot
Temperature0 to 70 C, -40 to 85 C on the HX parts0 to 70 C, -40 to 85 C on the HX parts

Included Models and Order Codes

The table lists the order codes most often quoted for switches, gateways and industrial controllers. State the speed, the number of ports, the PoE class, the temperature range and the PHY it will be paired with, and the module and its packing are confirmed.

Part NumberSpeedPortsInsertion LossIsolationNotes
H1102NL10/100BASE-TX11.1 dB maximum1500 Vrms350 microhenry, 0 to 70 C, 12.7 by 7.1 mm
HX1188NL10/100BASE-TX11.0 dB maximum1500 Vrms350 microhenry, -40 to 85 C
H1199NL10/100BASE-TX10.9 dB maximum1500 Vrms350 microhenry, 0 to 70 C
H5008NL1000BASE-T11.0 dB maximum1500 Vrms1:1, 18 dB return loss at 30 MHz
HX5008NL1000BASE-T11.0 dB maximum1500 VrmsFour pair PoE at 30 W, -40 to 85 C
H5012NL1000BASE-T21.4 dB maximum1500 VrmsDual port, 1:1, common mode choke included
H5014NL1000BASE-T21.4 dB maximum1500 VrmsDual port, 1:1, centre tap bypass
HX5014NL1000BASE-T21.4 dB maximum1500 VrmsDual port, extended temperature

Key Features

Isolation that passes hipot – 1500 Vrms between the cable side and the PHY side is the number the safety test looks for, and it is quoted per module rather than per transformer.

Common mode rejection – 43 dB at 30 MHz on the gigabit parts is what keeps the cable from radiating the PHY clock, which is the usual cause of a failed emissions run.

PoE ready – the four pair parts are rated for 30 W at the module, so the centre taps can carry the current without saturating the core.

Return loss – 18 to 20 dB at 30 MHz keeps the PHY eye open on a long cable, and it is the first figure to fall when a cheaper core is used.

Single and dual port – a two port module halves the placement count on a gateway, and a single port module keeps the routing straight on a controller with one copper port.

Extended temperature – the HX parts are rated from -40 to 85 C, which is what an outdoor access point or a DIN rail switch needs.

Applications

These modules are quoted for equipment with a copper Ethernet port, typically where: A network port is normally quoted with the SUPERB PCB and SUPERB PCBA work we support for the same assembly, so the magnetics, the RJ45 and the termination network are handled together.

Industrial switches and gateways – a DIN rail device with two copper ports needs a dual module with PoE and an extended temperature rating, and a 1.4 dB loss budget across the module.

Access points and cameras – a PoE powered device needs a module rated for four pair power, so the centre tap can carry 30 W without saturating the core.

Instrument and controller ports – a single port controller needs a 1:1 module with 1500 V isolation and a footprint that fits beside the RJ45.

Sourcing and Cross-Reference

Magnetics are the part of an Ethernet port most often copied from a reference circuit and least often re-measured. A module with the same turns ratio but a different core will pass traffic and fail the emissions or the hipot test, and a PoE module replaced by a non PoE part will work at 15 W and saturate at 30 W. We quote the turns ratio, the inductance, the insertion loss, the return loss and the PoE rating on the confirmation, so the replacement is checked against the port budget.

The connector and the module are a pair. The centre tap bypass, the Bob Smith termination, the chassis ground and the distance from the PHY all change the result, and a module that measures 43 dB of common mode rejection on a test board will measure 30 dB when the RJ45 shield is tied to the wrong plane. We quote the module with the connector and the termination network, and review the layout before the first panel where a port has to pass class B.

Where the port boards are built in volume, SUPERB Assembly support covers the placement of the module and the connector and the selective coating that the isolation barrier needs.

Q: Do you supply PoE rated Ethernet magnetics for an industrial switch with two copper ports?

A: Yes. Send the speed, the number of ports, the PoE class, the temperature range and the PHY, and the SUPERB Tech sales team will confirm the order code, the packing and the module that fits the same footprint.

Why Buyers Source LAN Magnetics Through SUPERB

  1. Port budget on the quote: insertion loss, return loss, common mode rejection and the PoE rating are stated per line, so the module is checked against the PHY and the cable run.
  2. Module and connector together: the RJ45, the termination network and the chassis ground are quoted with the magnetics, which is where a port passes or fails class B.
  3. Extended temperature parts: the HX range is held for outdoor and DIN rail products, so a product does not have to be re-qualified around a 0 to 70 C part.
  4. Board build: placement, isolation slot and coating are agreed with the same team that supplies the parts, which keeps the hipot result repeatable.