Contact Us

Captive Panel Screws and Quarter Turn Fasteners

A captive screw stays in the panel when the joint opens, so the fastener cannot be dropped inside a rack or lost on a bench. The self clinching parts here cover M3 to M6 and number 4-40 to number 8-32, with a 5.56 mm to 9.53 mm hole in the sheet. Quarter turn fasteners run from a 2.3 mm to a 15.9 mm total material thickness, selected by a stud length code from 100 to 580. Both families are ordered by the panel stack, not by the screw thread alone.
quote now

Product Specifications

Product Overview

A captive screw is a fastener that stays with the panel when the joint is opened. That is the whole point of the part: on a rack front, a terminal cover or a sealed access door, a loose screw is a screw that ends up inside the equipment. The fastener is held in the panel by a knurled body that is pressed into the sheet, and the screw travels in that body without coming out.

The self clinching family on this page is the PEM PF11, PF12 and PF15 series, with a spring that lifts the screw clear of the frame when it is released, and the PF7M and PF7H family without it. In the metric sizes the sheet hole is 5.56 mm for M3, 6.35 mm for M3.5, 7.92 mm for M4 and M5, and 9.53 mm for M6, all with a plus 0.08 mm tolerance. The minimum sheet thickness is 0.92 mm across the range, which is why a 1 mm aluminium front panel is the usual host and a 0.6 mm cover is not.

Screw length is a code, not a number of millimetres. On the M3 part the three length codes give a maximum screw projection of 4.32 mm, 5.84 mm and 7.37 mm, and the M6 part gives 7.37 mm, 8.89 mm and 10.41 mm. The installed height above the sheet, which is what a rack rail sees, runs from 7.87 mm on the M3 to 13.46 mm on the M6, with the fastened height at 11.43 mm to 20.07 mm. The driver size moves with it, from a number 1 to a number 3 recess.

Two other dimensions decide the panel. The minimum distance from the hole centre to the sheet edge is 7.11 mm on the M3 part and 11.68 mm on the M6 part, so a screw placed 6 mm from the edge of a thin panel tears the corner out. And the head diameter, 5.54 mm to 14.61 mm depending on thread, sets the clearance to a neighbouring fastener.

The second family on the page is the quarter turn fastener, which does not use a thread at all. A stud passes through the outer panel and engages a receptacle on the frame with a quarter of a turn, and the joint opens in one movement. The Southco 82 DZUS range is the one on this page: a 9.5 mm stud through a 6.4 mm hole, in steel with a zinc and chromate finish or in stainless, with head styles from an oval slot to a wing head, a bail handle, a Phillips recess and a hex recess.

A quarter turn part is selected by total material thickness, which is the sum of the outer panel, the frame and any gap or retainer. The stud length code is read from that figure: code 100 covers 2.3 mm to 2.8 mm, code 200 covers 4.8 mm to 5.3 mm, code 400 covers 9.9 mm to 10.4 mm and code 580 covers 14.5 mm to 15.9 mm, in steps of 0.5 mm along the table. The part number is built as 82, head style, length code and material, so a wing head in steel at a 12.7 mm total thickness is 82-12-500-16.

The receptacle is the other half of that part and it is not interchangeable between families. A clip on receptacle, a press in receptacle and a rivet on receptacle each have their own adjustment value, and that value is added to the total thickness before the stud length is chosen. Ordering a stud from the panel thickness alone is the usual way a quarter turn joint ends up either too tight to turn or too loose to hold.

Both families are also available with a sealing washer or a gasket behind the head, which is what turns a fastener into a sealed fastener on an outdoor cabinet. That washer is a separate line on the drawing, and its compressed thickness changes the total material thickness, so it has to be in the calculation before the stud length is fixed.

Key Specifications

ParameterValueNotes
Captive screw threadsM3, M3.5, M4, M5, M6 and number 4-40 to number 8-32Metric and inch series
Sheet hole size5.56 mm to 9.53 mm plus 0.08 mmPer thread size
Minimum sheet thickness0.92 mmSelf clinching body
Screw length codesThree per thread sizeProjection 4.32 mm to 10.41 mm
Installed height above sheet7.87 mm to 13.46 mmKnob height at the panel face
Fastened height11.43 mm to 20.07 mmAbove the sheet when closed
Driver recessNumber 1 to number 3Phillips or slot per part
Minimum hole to edge7.11 mm to 11.68 mmGrows with the thread size
Quarter turn stud diameter9.5 mmThrough a 6.4 mm panel hole
Quarter turn material thickness2.3 mm to 15.9 mmSelected by the stud length code
Quarter turn materialsSteel, zinc plated and chromate, or stainlessStainless needs a longer lead time on some heads
Quarter turn head stylesOval slot, wing, bail RA, bail RB, oval Phillips, flush Phillips, hex, tool headTool head not offered in stainless

Included Models and Order Codes

The captive screws are listed by thread size with the hole in the sheet, the installed height and the driver recess. The quarter turn studs are listed by length code with the total material thickness each code covers, because that is the number the panel drawing gives.

Part FamilyThread or StudHole or PanelThickness or HeightDriver or HeadNotes
PF11 M3M3 x 0.55.56 mm holeInstalled 7.87 mmNumber 1 recessSpring loaded, three lengths
PF11 M3.5M3.5 x 0.66.35 mm holeInstalled 11.43 mmNumber 2 recessSpring loaded
PF11 M4M4 x 0.77.92 mm holeInstalled 11.43 mmNumber 2 recessSpring loaded
PF11 M5M5 x 0.87.92 mm holeInstalled 11.43 mmNumber 2 recessSpring loaded
PF11 M6M6 x 19.53 mm holeInstalled 13.46 mmNumber 3 recessSpring loaded
PF7M M3M3 x 0.55.56 mm holeMin sheet 0.92 mmNumber 2 recessWithout spring
PF7M M4M4 x 0.77.92 mm holeMin sheet 0.92 mmNumber 2 recessWithout spring
PF7M 440Number 4-400.219 in holeMin sheet 0.036 inNumber 2 recessInch series
PF7M 632Number 6-320.250 in holeMin sheet 0.036 inNumber 2 recessInch series
PF7M 832Number 8-320.312 in holeMin sheet 0.036 inNumber 2 recessInch series
82-11-100-16Quarter turn, K 1006.4 mm panel hole2.3 mm to 2.8 mmOval slotSteel, zinc
82-11-200-16Quarter turn, K 2006.4 mm panel hole4.8 mm to 5.3 mmOval slotSteel, zinc
82-15-300-16Quarter turn, K 3006.4 mm panel hole7.4 mm to 7.9 mmBail handle RASteel, zinc
82-19-400-16Quarter turn, K 4006.4 mm panel hole9.9 mm to 10.4 mmOval PhillipsSteel, zinc
82-15-400-20Quarter turn, K 4006.4 mm panel hole9.9 mm to 10.4 mmBail handle RAStainless, passivated
82-28-500-16Quarter turn, K 5006.4 mm panel hole12.5 mm to 12.9 mmFlush PhillipsSteel, zinc
82-12-580-16Quarter turn, K 5806.4 mm panel hole14.5 mm to 15.9 mmWing headSteel, zinc
82-78-200-16Quarter turn, K 2006.4 mm panel hole4.8 mm to 5.3 mmHex recessSteel, zinc

Key Features

Screw stays with the panel – The knurled body is pressed into the sheet, so the fastener cannot be dropped into a rack or lost on a bench.

Spring lift on release – The PF11 and PF12 parts lift the screw clear of the frame, which is what lets a hinged panel close without catching the thread.

Hole size stated per thread – 5.56 mm for M3 up to 9.53 mm for M6, plus 0.08 mm, so the panel is punched once and the body presses in without a burr.

Edge distance given – 7.11 mm to 11.68 mm from the hole centre to the sheet edge, which stops a thin panel tearing at the corner.

Height published both ways – Installed height and fastened height are listed, because a rack rail cares about the first and the joint about the second.

Quarter turn by material thickness – Stud length codes from 100 to 580 cover 2.3 mm to 15.9 mm, so the joint is selected rather than guessed.

Steel and stainless on the same table – The same head style in zinc plated steel or in stainless, with the material code as the last block of the part number.

Applications

These fasteners go on rack fronts, access covers, sealed hatches, instrument lids and battery doors, wherever a screw has to come out without being lost.

Rack front panels – Spring loaded M4 or M5 captive screws on a 1.5 mm front panel, with the installed height checked against the rail spacing.

Sealed access hatches – Quarter turn studs with a sealed receptacle on a hatch that is opened weekly, where a quarter of a turn is faster than four screws.

Instrument and battery doors – PF7M M3 parts without a spring on a cover that is removed for service and stored with the panel.

Field terminal covers – Number 6-32 inch series parts on a cover that has to stay attached in the wind, with the screw captive to the lid.

A captive screw is specified by the panel thickness it has to span and the thread it has to land in, and the SUPERB PCB front panel drawing carries both, so the screw is ordered against the panel stack rather than against the head style. On the SUPERB PCBA route the fasteners are fitted after the front panel is printed, because a screw that is already captive traps swarf under its knob.

Sourcing and Cross-Reference

A captive screw is ordered from the panel stack: sheet thickness, hole size, thread and the height the knob is allowed to stand above the face. Three of those four are on the front panel drawing, and the fourth is usually a clearance to a rack rail or a neighbouring part. We ask for all of them before we quote, because the length code is where a cross reference usually fails.

Quarter turn parts add one more step: the receptacle. The adjustment value of the receptacle is added to the total material thickness before the stud length is read from the table, and a clip on receptacle has a different value from a press in one. A stud chosen without that value turns either too tight to operate or too loose to hold the panel against its gasket.

Where a part number has been superseded, the substitute is matched on hole size, thread and installed height. A slightly longer screw in the same body is usually acceptable; a body with a different hole size is not, because it reams the panel. We check the drawing before we offer the alternative and we say when a new punching is needed.

SUPERB Assembly fits one fastener of each size to a sample panel and checks the installed height and the spring return, because a captive screw whose knob stands 2 mm above the panel catches on a rack rail and shears in service.

Q: Can you supply M4 spring loaded captive panel screws for a 1.5 mm front panel, and confirm the hole size and the installed height against our rack?

A: Send the panel thickness, the frame thickness, the thread size, the material of both panels and whether the screw has to be spring loaded. The SUPERB Tech desk quotes the part number with its hole size and its installed height, so the panel is punched once.

Why Buy Fasteners Through SUPERB

  1. Quoted from the panel stack: Sheet thickness, hole size, thread and installed height are confirmed together, which is where a captive screw order usually goes wrong.
  2. Metric and inch on one desk: M3 to M6 and number 4-40 to number 8-32, so a panel that mixes standards is quoted as one package.
  3. Quarter turn receptacle included: The receptacle and its adjustment value are part of the quotation, so the stud length is right the first time.
  4. Heights and edge distances published: Installed height, fastened height and minimum hole to edge are listed with the part, which is what the drawing checker needs.
  5. Small quantities and samples: Ten fasteners for a first article are quoted without a tooling charge, because the body is a standard part.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Standoffs, Spacers and Mounting Hardware for Board Stacks, Threaded Inserts and Standoff Nuts for Plastic Enclosures, Continuous and Butt Hinges for Enclosure Doors, Draw Latches and Toggle Latches for Enclosure Doors, Enclosure Handles and Corner Guards for Portable Units, Obsolete Part Cross Reference Hub.