Contact Us

VBN1606

Brand: VBsemi
VBsemi VBN1606 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

VBN1606 — Discrete & Power Semiconductors | Superb Automation

VBN1606

VBsemi — Discrete & Power Semiconductors

Product Overview

The VBN1606 from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

VBN1606: 60 V and 120 A with 6 milliohm in a TO262

The VBN1606 is a single N channel MOSFET in a TO262 outline rated at 60 V drain to source, plus or minus 20 V on the gate, a 2.5 V threshold, 120 A of drain current and 6 milliohm at a 10 V gate. The catalogue page prints one resistance column for this part rather than the three used elsewhere in the band, which is a limitation of the page rather than of the die, and the 4.5 V figure has to be requested before a 5 V drive is assumed.

Sixty volts is the class for a 48 V telecom rail with a hot plug transient, a 48 V battery pack at full charge with a modest spike, a 36 V industrial bus and the intermediate rail of a two stage converter. It is a common class because 48 V is common, and the choice inside it is made on resistance and on thermal path.

Six milliohm at 120 A is 86 W, at 50 A it is 15 W, at 30 A it is 5.4 W, at 20 A it is 2.4 W. With the tab soldered to a copper area the working range is 20 to 40 A, and with a bar or a sink it reaches 50 A.

Key data for the VBN1606

ConfigurationSingle N channel
PackageTO262, tab soldered to the board
VDS60 V
VGSPlus or minus 20 V
Vth2.5 V typical
ID120 A, a die figure at a 25 C case
RDS(on) at 10 V6 milliohm
RDS(on) at 4.5 VNot printed on the catalogue page, ask before a 5 V drive is assumed
TechnologyTrench
Loss at 20 A2.4 W
Loss at 30 A5.4 W
Loss at 50 A15 W

The missing 4.5 V column and why it matters

On most parts in this band the gap between the 4.5 V and the 10 V column is 1.5 to 2.3 times. If this die follows the same pattern, the 4.5 V figure is around 10 to 14 milliohm, which nearly doubles the conduction loss. A circuit that assumed 6 milliohm and a 5 V drive would run at twice the calculated temperature.

The 2.5 V threshold is mid band and it suggests the part is not a dedicated logic level die. A logic level part would print 1.5 to 1.8 V and a resistance that stays close to its 10 V value at 4.5 V. This one sits between the two, so the 10 V figure is the one to trust and the 4.5 V figure has to be measured or requested.

None of this makes the part wrong. It makes the drive a decision rather than an assumption. With a 10 V driver and a short gate loop the printed 6 milliohm is the number that applies, and the part is a good 48 V switch. With a 5 V gate from a microcontroller it needs a driver stage, which is a small cost next to a board that runs 30 C hotter than expected.

Package and thermal in a 48 V system

The TO262 tab soldered to a 600 square millimetre copper area on two ounce copper holds about 5 W with the junction at 110 C in still air, which is 30 A for this part. That is the natural operating point for a 48 V load switch or a synchronous rectifier in a 500 W converter.

At 50 A the loss is 15 W and the board alone is not enough. A copper bar clamped over the tab, or a small extrusion fixed to the tab, brings the junction back under 110 C. The bar is the usual choice in a telecom board because it also carries the current between stages.

The leads are part of the current path. At 50 A a single lead pair with 0.5 milliohm contributes 0.6 W per lead, and the source lead is usually the hotter one because it carries the gate return as well. A wide copper landing under each lead rather than a narrow pad is the difference between a 20 C rise and a 40 C rise at the pin.

Where the part fits and where it does not

It fits a 48 V load switch, a synchronous rectifier in a 48 V to 12 V converter, a battery disconnect on a 48 V pack, a motor driver on a 36 V bus and a hot swap stage on a 48 V backplane. It does not fit a 72 V battery, a 400 V bus, or a 100 A continuous load on a board without a bar.

Where a 60 V part is being replaced after a shortage, the check is on the resistance at the real gate voltage, because the missing 4.5 V column makes this part look better than it is on a 5 V drive. Our how to verify a drop in replacement page covers the measurements that settle it before a lot is released to the line.

The sourcing side of this part is covered on the material requirements planning. For a 48 V part on a rolling schedule, that page covers how the demand is carried against the plan.

Questions we get on this code

Where is the 4.5 V resistance? It is not on the catalogue page. We ask the supplier for the curve rather than guessing, and we do not quote a figure we have not seen.

Can it run at 120 A? No. At that current the die makes 86 W and the tab cannot remove it. Twenty to forty amps on copper is the realistic range.

Is 60 V enough for a 48 V pack? For a nominal 48 V pack that charges to 54 V, yes with a clamp and a short wiring run. For a 60 V class pack at 60 V plus spikes, a 75 V or 100 V part is safer.

What does the order carry? Part number, TO262, and tube packing. We confirm the packing and the date code on the offer.