Contact Us

VBM165R20SE

Brand: VBsemi
VBsemi VBM165R20SE is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

VBM165R20SE — Discrete & Power Semiconductors | Superb Automation

VBM165R20SE

VBsemi — Discrete & Power Semiconductors

Product Overview

The VBM165R20SE from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

VBM165R20SE: 650 V and 20 A at 150 milliohm

The VBM165R20SE is a single N channel MOSFET in a TO220 body rated at 650 V drain to source, plus or minus 30 V on the gate, a 3.5 V threshold, 20 A of drain current and 150 milliohm at a 10 V gate. The die is listed as SJ deep trench.

Six hundred and fifty volts is the most common class for a 230 V AC front end, because a 325 V bus with a 400 V transient allowance and a switching spike lands under 650 V in most products. It is also the class used on a 400 V DC bus in a drive or a solar converter.

One hundred and fifty milliohm at 20 A is 60 W. At 10 A it is 15 W. At 5 A it is 3.75 W. On a TO220 with a clip on heatsink the working current is 8 to 12 A, and the part is comfortable there.

Key data for the VBM165R20SE

ConfigurationSingle N channel
PackageTO220 through hole with a metal tab
VDS650 V
VGSPlus or minus 30 V
Vth3.5 V
ID20 A, a die figure at a 25 C case
RDS(on) at 10 V150 milliohm
TechnologySJ deep trench
Loss at 5 A3.75 W at 150 milliohm
Loss at 10 A15 W at 150 milliohm
Loss at 20 A60 W at 150 milliohm
Gate chargeNot printed, ask for the curve at the working drain voltage

Deep trench at six hundred and fifty volts

The deep trench structure puts the field plate deeper into the drift region than a multiple epitaxy stack, which raises the charge balance and lowers the resistance per unit of breakdown voltage. On a 650 V die at 150 milliohm the gain is visible: a planar part of the same area would be nearer 300 to 500 milliohm.

The price is a body diode with a sharper recovery and a gate charge that is higher than a planar part of the same resistance. In a hard switched bridge the recovery is the loss that decides the frequency, and at 650 V and 10 A it is worth a few watts in the opposite switch.

Where the topology is a flyback or a boost, there is no opposite switch to absorb the recovery and the diode only matters during the dead time. In those topologies the part is easier to use and the frequency can go higher, until the output capacitance loss becomes the limit.

Six hundred and fifty volts and the three voltage sum.

In a flyback the drain voltage is the bus plus the reflected secondary voltage plus the leakage spike. On a 325 V bus with 120 V reflected and a 100 V spike the sum is 545 V, which is inside 650 V with 105 V of margin. On a 400 V bus the same arithmetic gives 620 V, which is tight and needs a clamp.

In a bridge the drain sees the bus plus the spike from the commutation loop, which is smaller because the loop is short. That is why a bridge leg at 400 V can use a 500 V part and a flyback at the same bus often needs 650 V.

The clamp is what makes the difference. An active clamp or a well damped snubber can hold the spike to 50 V and turn a marginal product into a comfortable one, at the cost of a few parts and a little loss. Without one, the margin has to come from the voltage class.

Thermal and the gate drive at 650 V

At 10 A the loss is 15 W and a clip on heatsink holds it with the tab insulated. At 15 A it is 34 W and the part needs a larger heatsink and airflow. The tab is the drain at 325 V, so a shared heatsink needs an insulator rated for the voltage, and the creepage to the mounting screw is part of the board.

The 30 V gate window allows a 12 V drive with room for ringing, which is what a 650 V node needs. A 10 V drive reaches most of the resistance and is often enough. What must be avoided is a drive that is slow enough to spend microseconds in the linear region at every transition, because at 325 V that is where the switching loss is made.

The threshold of 3.5 V is high enough that a pull down of tens of kilohm keeps the part off, and low enough that a 10 V drive enhances it fully. The gate resistor sets the transition time against the ringing, and on a 325 V rail with a fast diode the balance is usually 10 to 22 ohm.

Where the part fits and where it does not

It fits a 230 V AC power factor stage at 5 to 10 A, a flyback in a charger at 30 to 60 kHz, a boost converter on a 400 V bus, an inverter leg in a small drive and an active clamp. It does not fit a 20 A continuous load in a TO220, a 480 V AC input without a clamp, or a resonant converter above 100 kHz.

For a 650 V front end the questions are the sum of the three voltages, the clamp and the diode recovery. Our component shortage forecast page covers how a shortage on a part like this is seen before it stops a line.

The sourcing side of this part is covered on the strategic sourcing. For a 650 V part that several products depend on, that page covers how the source is qualified and held.

Questions we get on this code

Does 650 V cover a 400 V bus? In a bridge, yes with a clamp. In a flyback the reflected voltage and the spike are added, and the sum can exceed 650 V.

Is 20 A available? At 60 W, no. On a clip on heatsink 8 to 12 A is the working range.

Does the tab need an insulator? Yes. The tab is the drain at the bus voltage, so a shared heatsink needs an insulator and a shoulder washer.

What should a purchase order carry? Part number, TO220, and the packing the line can take. We confirm the tube quantity on the offer.