VBL18R17S
Product Specifications
VBL18R17S
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBL18R17S from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBL18R17S: 800 V and 17 A in a TO263 body
The VBL18R17S is a single N channel MOSFET in a TO263 body rated at 800 V drain to source, plus or minus 30 V on the gate, a 3.5 V threshold, 17 A of drain current and 220 milliohm at a 10 V gate. The die is listed as SJ multiple epitaxy.
Eight hundred volts is one class above the 700 V parts in this band and it exists for two situations. The first is a 480 V AC drive where the bus sits near 680 V and the transient allowance is larger than 20 V. The second is a photovoltaic string where the open circuit voltage at the coldest morning is well above the nominal, and a 700 V part would be inside its rating only on a warm day.
Two hundred and twenty milliohm sets the working current far below the label. At 17 A the loss is 63.6 W. At 8 A it is 14 W. At 4 A it is 3.5 W. The part is a few amp switch with a large voltage margin, and that is what it is bought for.
Key data for the VBL18R17S
| Configuration | Single N channel |
| Package | TO263, surface mount with the tab on the drain |
| VDS | 800 V |
| VGS | Plus or minus 30 V |
| Vth | 3.5 V |
| ID | 17 A, a die figure at a 25 C case |
| RDS(on) at 10 V | 220 milliohm |
| Technology | SJ multiple epitaxy |
| Loss at 4 A | 3.5 W at 220 milliohm |
| Loss at 8 A | 14 W at 220 milliohm |
| Loss at 17 A | 63.6 W at 220 milliohm |
| Gate charge | Not printed, ask for the curve at the working drain voltage |
What the extra hundred volts cost
Between the 700 V and the 800 V part in this band the resistance is close, 210 against 220 milliohm, so the extra voltage is nearly free in conduction terms. What it costs is a slightly larger die for the same resistance and a body diode with a little more stored charge, both of which show up at the switching frequency rather than in the conduction table.
The gain is margin. On a 680 V bus the 800 V part has 120 V of margin where the 700 V part has 20 V, and that difference decides whether a snubber is a refinement or a necessity. On a photovoltaic string the difference can be the whole qualification, because the open circuit voltage at minus ten degrees is a published number and the product has to hold it.
The rule of thumb of 80 per cent is not a law but it is a reasonable starting point. At 800 V the derated ceiling is 640 V, which is below a 680 V bus, so a product at that voltage has to justify the choice on the clamped transient rather than on the rule. At 700 V the ceiling is 560 V, which is below the same bus by more. The rule is a prompt to think, not a substitute for the clamp voltage.
Photovoltaic strings and the cold morning.
A string of 14 modules at 45 V open circuit is 630 V at 25 C and about 700 V at minus ten, because the open circuit voltage has a negative temperature coefficient of roughly 0.3 per cent per degree and it rises as the cells cool. A 700 V part on that string is inside its rating at 25 C and outside it on a winter morning before the inverter has started.
That is the case an 800 V class is made for. The same arithmetic applies to a 1000 V string, which needs the 1200 V class, and to a 600 V string where a 700 V part is enough.
The switch in a string level converter also sees the reverse recovery of any diode in the loop and the surge of a lightning arrestor clamp, so the margin is not only for the string voltage. A varistor at the string terminals, a clamp across the bus and a snubber across the switch together keep the drain inside the class.
Driving a 30 V gate window at 800 V
The plus or minus 30 V window allows a 15 V drive with a negative off bias, which is the normal arrangement on a high voltage bridge. A minus 5 V off state is enough to keep the device off while the opposite diode recovers, and the window leaves room for the ringing that comes with a fast turn off at 680 V.
At this voltage the gate loop picks up displacement current through the drain to gate capacitance at every transition. The current flows through the gate resistor and appears as a voltage that can approach the threshold. A low impedance driver with a short return, a resistor of 10 to 33 ohm and a small capacitor from gate to source close to the package are the usual defences.
The threshold of 3.5 V is high enough to be useful and low enough to be a hazard at the same time. It means a 10 V drive enhances the die fully, and it means a 3 V spike on a gate held at zero is a partial turn on. Where the part sits in a bridge, the off state has to be a real bias rather than a resistor to ground.
Thermal limits at 680 V.
The tab is the drain and it swings with the switching node, which makes the copper island a live surface at 680 V. Area is needed for heat and distance is needed for creepage, and on a surface mount body those two compete. A coated board is often the cheaper answer than a slotted copper island.
At 4 A the loss is 3.5 W and a pad of a few square centimetres holds it. At 8 A it is 14 W and the part wants airflow. At 12 A it is 32 W and the package is beyond what any pad can do without a heatsink. The working continuous current on a two layer board is 4 to 6 A.
Switching loss adds to that at every transition, and at 680 V it is not small. A die with this capacitance discharging into the channel at 30 kHz can lose a couple of watts in the transition alone, which is comparable to the conduction loss at 4 A. That is why the frequency on a rail this high stays low.
Where the part fits and where it does not
It fits a photovoltaic string switch, a 680 V bus auxiliary supply, an active clamp on a 480 V drive, a high voltage discharge path and a start up circuit that has to hold a cold morning open circuit voltage. It does not fit a continuous 17 A load, a 1000 V string, or a high frequency converter without an added diode.
For a string switch the questions are the open circuit voltage at the coldest day, the clamp the installer fits and the resistance at the drive voltage available. Our kitting service page covers how a group of parts for one build is assembled and checked before it reaches the line.
The sourcing side of this part is covered on the component obsolescence management. For an 800 V part in a product that ships for a decade, that page covers how the supply is watched before the family narrows.
Questions we get on this code
Does 800 V cover a 1000 V string? No. A 1000 V string reaches about 1100 V open circuit in the cold, which is the 1200 V class. This part is for strings up to about 700 V open circuit.
Is the 17 A rating usable? Not continuously. At 63.6 W the package cannot remove it. Four to six amps on a good pad is the working range.
Why is the gate window 30 V here and 20 V on other parts? A wider window tolerates a negative off bias and more ringing, which a high voltage bridge needs. A part rated at 20 V forces a gentler driver.
What should a purchase order carry? Part number, TO263, and the packing the line can take. We confirm the reel quantity on the offer.