Contact Us

HXN40046

Brand: Hisiwell
Hisiwell HXN40046 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXN40046 — Discrete & Power Semiconductors | Superb Automation

HXN40046

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXN40046 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXN40046: 100 W of continuous wave over 4.2 to 4.4 GHz

The HXN40046 is the first C band part in this batch and the narrowest band of the ten: 4.2 to 4.4 GHz, 200 MHz wide, at 50 dBm saturated, which is 100 W, with 10 dB of gain and 48 per cent drain efficiency from a 28 V rail, continuous wave, with plus or minus 0.8 dB of flatness.

At 48 per cent the rail supplies 208.3 W, the drain current is 7.44 A at 28 V, and the heat is 108.3 W. A hundred watts of radio frequency and a hundred watts of heat in the same flange, continuously, is the defining constraint of this part: nothing here is averaged over a duty cycle.

The 200 MHz window is a deliberate narrowing. At 4.3 GHz a 200 MHz match covers a specific allocation, and the efficiency of 48 per cent is a point higher than the octave members at 3 GHz, which is what the narrower match buys. A system that needs to move across 4.0 to 4.8 GHz needs a different part, and the family continues with members at 4.4 to 5 GHz.

The gain row is 10 dB, the lowest of the ten, so the drive is 10 W. A hundred watts out of ten watts in is a chain where the driver is a real amplifier and where every tenth of a decibel of interconnect loss is 2.3 per cent of the input.

The parameter rows Hisiwell publishes for HXN40046

Part classGallium nitride power transistor, internally matched
Frequency range4.2 to 4.4 GHz
Bandwidth, calculated200 MHz, 5 per cent fractional
Saturation output power as publishedat least 50 dBm
Saturation output power in watts, calculated100.0 W
Gain as publishedat least 10 dB
Drain efficiency as publishedat least 48 per cent
Drain voltage28 V
Flatness across the bandplus or minus 0.8 dB
Operating modecontinuous wave
Input impedance50 ohm
Output impedance50 ohm
Output at 1 dB compressionnot published, the index prints a slash
DC input at saturation, calculated208.3 W
Drain current at saturation, calculated7.44 A at 28 V
Dissipation at saturation, calculated108.3 W
Dissipation if efficiency falls to 40 per cent, calculated150.0 W
Drive power for the rated output, calculated40 dBm, 10.0 W
Output if efficiency rises to 55 per cent, calculated118.2 W of radio frequency from the same DC input
Output per 100 MHz of the band, calculated50.0 W
Thermal resistance, junction to casenot published
Package outline and dimensionsnot published in text, one image on the product page
Scattering parametersnot published
Pinch off voltage and gate bias pointnot published on this page
Operating and storage temperaturenot published
Moisture level and floor lifenot published
Orderable addendum and packingnot published
Neighbour over 3.4 to 3.9 GHz at 79.4 WHXN40043, same rail, 11 dB gain
Neighbour over 4.4 to 5 GHz at 37 dBmHXN40047, same rail, 12 dB gain

A hundred and eight watts of steady heat at C band

Continuous wave at 108.3 W is the hardest cooling case in this batch. A carrier at 1 C per watt gives 108 C of rise, which is a liquid cooled plate; at 0.5 C per watt it is 54 C, which needs a large forced air heatsink with a good interface; at 3 C per watt the part fails before it reaches full output. The vendor publishes no junction to case figure, so this is a measured case temperature exercise on the first article, not a calculation from the sheet.

The feed is the second constraint. Seven point four four amperes at 28 V means the path from the supply to the flange has to be short and wide, and the decoupling has to be effective at 4.3 GHz rather than only at the regulator's switching frequency. A feed that works at 3 GHz can look inductive at 4.3 GHz, which shows up as a gain that collapses at the top of the band.

Efficiency at 40 per cent raises the heat to 150 W and the current to 8.93 A, a 39 per cent increase in the cooling load for the same 100 W. The 48 per cent row carries no typical marker, so it is the published value and a floor has to be specified.

The window is 200 MHz, the narrowest of the ten, so the match is the least compromised of the batch. That is consistent with the 48 per cent at C band, where the die is smaller for the same power and the match losses are relatively more costly.

Ten decibels and a chain that has to be built around it

At 10 dB of gain the drive is 10 W, the same as the 158.5 W member on the S band octave, which means the driver stage for this part is a familiar size. What is not familiar is the frequency: a 10 W driver at 4.3 GHz is a narrower market than at 3 GHz, and the driver choice constrains the whole system.

The 10 dB row also leaves little room for the isolation and the cabling. An isolator at 0.4 dB, a connector pair at 0.2 dB and a short cable at 0.3 dB add up to 0.9 dB, which is 2.06 W of the 10 W budget, so the driver has to deliver about 12.3 W to put 10 W at this flange. That is the kind of margin a chain plan has to carry from the start.

With no compression point and no gain curve published, the only published behaviour is the saturated power at the band and the flatness across it. A modulated carrier running 4 dB backed off is not described by the sheet, and the linearity has to be measured.

Where a 100 W C band continuous wave stage fits

The fit is a C band transmitter or a driver for a larger stage: satellite uplink blocks in the 4.2 to 4.4 GHz allocation, fixed point to point links, radar with a continuous wave mode, and laboratory amplifiers for antenna and component testing at 4.3 GHz. A hundred watts continuous is enough for many of those and is the right size for driving a 300 to 500 W final stage.

It is a poor fit for a passive cooled enclosure, for a wideband requirement, for any system that needs a published compression figure, and for a platform whose driver cannot supply 10 W at 4.3 GHz. Our RF power transistor cross reference work shows this part against the 79.4 W member below it and the 5 W members above it, with the rail and the gain printed, because the ladder continues into 4.4 to 5 GHz with a very different power class.

Where a second source is being examined, the drop in replacement check starts from the flange, the pin positions and the 50 ohm ports, since two 50 dBm parts at different bands in different flanges are not interchangeable in a built assembly.

Questions we answer on HXN40046 before a lot is booked

The first is the cooling. At 108.3 W continuous the answer is a hard constraint, not a margin to be tuned later.

The second is the driver at 4.3 GHz, which is a smaller market than at 3 GHz and decides the shape of the chain.

The third is the lot. With no orderable addendum, no marking code and no moisture level published, the purchase order names the band, the rail and the mounting, and the incoming inspection plan records the flange and the DC behaviour of every lot. A saturated power sweep at 4.3 GHz and a case temperature at full output belong on the customer bench or at a partner RF laboratory, and the RF procurement process sets that division before the first order.

The neighbouring members at 4.4 to 5 GHz start at 37 dBm, which is 5 W, and run to 50 dBm on a narrower window, so a system that needs to move up in frequency should expect to change power class rather than to scale the same flange. That is worth knowing at the band plan stage, before a single amplifier chassis is committed to one frequency.